Cargando…
Development of an Electrochemical Immunosensor for Specific Detection of Visceral Leishmaniasis Using Gold-Modified Screen-Printed Carbon Electrodes
Visceral leishmaniasis is a reemerging neglected tropical disease with limitations for its diagnosis, including low concentration of antibodies in the serum of asymptomatic patients and cross-reactions. In this context, this work proposes an electrochemical immunosensor for the diagnosis of visceral...
Autores principales: | , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7460044/ https://www.ncbi.nlm.nih.gov/pubmed/32717832 http://dx.doi.org/10.3390/bios10080081 |
_version_ | 1783576510923276288 |
---|---|
author | Martins, Beatriz R. Barbosa, Yanne O. Andrade, Cristhianne M. R. Pereira, Loren Q. Simão, Guilherme F. de Oliveira, Carlo J. Correia, Dalmo Oliveira, Robson T. S. da Silva, Marcos V. Silva, Anielle C. A. Dantas, Noelio O. Rodrigues, Virmondes Muñoz, Rodrigo A. A. Alves-Balvedi, Renata P. |
author_facet | Martins, Beatriz R. Barbosa, Yanne O. Andrade, Cristhianne M. R. Pereira, Loren Q. Simão, Guilherme F. de Oliveira, Carlo J. Correia, Dalmo Oliveira, Robson T. S. da Silva, Marcos V. Silva, Anielle C. A. Dantas, Noelio O. Rodrigues, Virmondes Muñoz, Rodrigo A. A. Alves-Balvedi, Renata P. |
author_sort | Martins, Beatriz R. |
collection | PubMed |
description | Visceral leishmaniasis is a reemerging neglected tropical disease with limitations for its diagnosis, including low concentration of antibodies in the serum of asymptomatic patients and cross-reactions. In this context, this work proposes an electrochemical immunosensor for the diagnosis of visceral leishmaniasis in a more sensitive way that is capable of avoiding cross-reaction with Chagas disease (CD). Crude Leishmania infantum antigens tested in the enzyme-linked immunosorbent assay (ELISA) were methodologically standardized to best engage to the sensor. The antibodies anti-Trypanosoma cruzi and anti-Leishmania sp. Present in serum from patients with diverse types of CD or leishmaniasis were chosen. A screen-printed carbon electrode modified with gold nanoparticles was the best platform to guarantee effective adsorption of all antigens so that the epitope of specific recognition for leishmaniasis occurred efficiently and without cross-reaction with the evaluated CD. The current peaks reduced linearly after the recognition, and still were able to notice the discrimination between different kinds of diseases (digestive, cardiac, undetermined Chagas/acute and visceral chronic leishmaniasis). Comparative analyses with ELISA were performed with the same groups, and a low specificity (44%) was verified due to cross-reactions (high number of false positives) on ELISA tests, while the proposed immunosensor presented high selectivity and specificity (100%) without any false positives or false negatives for the serum samples from isolated patients with different types of CD and visceral leishmaniasis. Furthermore, the biosensor was stable for 5 days and presented a detection limit of 200 ng mL(−1). |
format | Online Article Text |
id | pubmed-7460044 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-74600442020-09-02 Development of an Electrochemical Immunosensor for Specific Detection of Visceral Leishmaniasis Using Gold-Modified Screen-Printed Carbon Electrodes Martins, Beatriz R. Barbosa, Yanne O. Andrade, Cristhianne M. R. Pereira, Loren Q. Simão, Guilherme F. de Oliveira, Carlo J. Correia, Dalmo Oliveira, Robson T. S. da Silva, Marcos V. Silva, Anielle C. A. Dantas, Noelio O. Rodrigues, Virmondes Muñoz, Rodrigo A. A. Alves-Balvedi, Renata P. Biosensors (Basel) Article Visceral leishmaniasis is a reemerging neglected tropical disease with limitations for its diagnosis, including low concentration of antibodies in the serum of asymptomatic patients and cross-reactions. In this context, this work proposes an electrochemical immunosensor for the diagnosis of visceral leishmaniasis in a more sensitive way that is capable of avoiding cross-reaction with Chagas disease (CD). Crude Leishmania infantum antigens tested in the enzyme-linked immunosorbent assay (ELISA) were methodologically standardized to best engage to the sensor. The antibodies anti-Trypanosoma cruzi and anti-Leishmania sp. Present in serum from patients with diverse types of CD or leishmaniasis were chosen. A screen-printed carbon electrode modified with gold nanoparticles was the best platform to guarantee effective adsorption of all antigens so that the epitope of specific recognition for leishmaniasis occurred efficiently and without cross-reaction with the evaluated CD. The current peaks reduced linearly after the recognition, and still were able to notice the discrimination between different kinds of diseases (digestive, cardiac, undetermined Chagas/acute and visceral chronic leishmaniasis). Comparative analyses with ELISA were performed with the same groups, and a low specificity (44%) was verified due to cross-reactions (high number of false positives) on ELISA tests, while the proposed immunosensor presented high selectivity and specificity (100%) without any false positives or false negatives for the serum samples from isolated patients with different types of CD and visceral leishmaniasis. Furthermore, the biosensor was stable for 5 days and presented a detection limit of 200 ng mL(−1). MDPI 2020-07-23 /pmc/articles/PMC7460044/ /pubmed/32717832 http://dx.doi.org/10.3390/bios10080081 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Martins, Beatriz R. Barbosa, Yanne O. Andrade, Cristhianne M. R. Pereira, Loren Q. Simão, Guilherme F. de Oliveira, Carlo J. Correia, Dalmo Oliveira, Robson T. S. da Silva, Marcos V. Silva, Anielle C. A. Dantas, Noelio O. Rodrigues, Virmondes Muñoz, Rodrigo A. A. Alves-Balvedi, Renata P. Development of an Electrochemical Immunosensor for Specific Detection of Visceral Leishmaniasis Using Gold-Modified Screen-Printed Carbon Electrodes |
title | Development of an Electrochemical Immunosensor for Specific Detection of Visceral Leishmaniasis Using Gold-Modified Screen-Printed Carbon Electrodes |
title_full | Development of an Electrochemical Immunosensor for Specific Detection of Visceral Leishmaniasis Using Gold-Modified Screen-Printed Carbon Electrodes |
title_fullStr | Development of an Electrochemical Immunosensor for Specific Detection of Visceral Leishmaniasis Using Gold-Modified Screen-Printed Carbon Electrodes |
title_full_unstemmed | Development of an Electrochemical Immunosensor for Specific Detection of Visceral Leishmaniasis Using Gold-Modified Screen-Printed Carbon Electrodes |
title_short | Development of an Electrochemical Immunosensor for Specific Detection of Visceral Leishmaniasis Using Gold-Modified Screen-Printed Carbon Electrodes |
title_sort | development of an electrochemical immunosensor for specific detection of visceral leishmaniasis using gold-modified screen-printed carbon electrodes |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7460044/ https://www.ncbi.nlm.nih.gov/pubmed/32717832 http://dx.doi.org/10.3390/bios10080081 |
work_keys_str_mv | AT martinsbeatrizr developmentofanelectrochemicalimmunosensorforspecificdetectionofvisceralleishmaniasisusinggoldmodifiedscreenprintedcarbonelectrodes AT barbosayanneo developmentofanelectrochemicalimmunosensorforspecificdetectionofvisceralleishmaniasisusinggoldmodifiedscreenprintedcarbonelectrodes AT andradecristhiannemr developmentofanelectrochemicalimmunosensorforspecificdetectionofvisceralleishmaniasisusinggoldmodifiedscreenprintedcarbonelectrodes AT pereiralorenq developmentofanelectrochemicalimmunosensorforspecificdetectionofvisceralleishmaniasisusinggoldmodifiedscreenprintedcarbonelectrodes AT simaoguilhermef developmentofanelectrochemicalimmunosensorforspecificdetectionofvisceralleishmaniasisusinggoldmodifiedscreenprintedcarbonelectrodes AT deoliveiracarloj developmentofanelectrochemicalimmunosensorforspecificdetectionofvisceralleishmaniasisusinggoldmodifiedscreenprintedcarbonelectrodes AT correiadalmo developmentofanelectrochemicalimmunosensorforspecificdetectionofvisceralleishmaniasisusinggoldmodifiedscreenprintedcarbonelectrodes AT oliveirarobsonts developmentofanelectrochemicalimmunosensorforspecificdetectionofvisceralleishmaniasisusinggoldmodifiedscreenprintedcarbonelectrodes AT dasilvamarcosv developmentofanelectrochemicalimmunosensorforspecificdetectionofvisceralleishmaniasisusinggoldmodifiedscreenprintedcarbonelectrodes AT silvaanielleca developmentofanelectrochemicalimmunosensorforspecificdetectionofvisceralleishmaniasisusinggoldmodifiedscreenprintedcarbonelectrodes AT dantasnoelioo developmentofanelectrochemicalimmunosensorforspecificdetectionofvisceralleishmaniasisusinggoldmodifiedscreenprintedcarbonelectrodes AT rodriguesvirmondes developmentofanelectrochemicalimmunosensorforspecificdetectionofvisceralleishmaniasisusinggoldmodifiedscreenprintedcarbonelectrodes AT munozrodrigoaa developmentofanelectrochemicalimmunosensorforspecificdetectionofvisceralleishmaniasisusinggoldmodifiedscreenprintedcarbonelectrodes AT alvesbalvedirenatap developmentofanelectrochemicalimmunosensorforspecificdetectionofvisceralleishmaniasisusinggoldmodifiedscreenprintedcarbonelectrodes |