Cargando…

Development of an Electrochemical Immunosensor for Specific Detection of Visceral Leishmaniasis Using Gold-Modified Screen-Printed Carbon Electrodes

Visceral leishmaniasis is a reemerging neglected tropical disease with limitations for its diagnosis, including low concentration of antibodies in the serum of asymptomatic patients and cross-reactions. In this context, this work proposes an electrochemical immunosensor for the diagnosis of visceral...

Descripción completa

Detalles Bibliográficos
Autores principales: Martins, Beatriz R., Barbosa, Yanne O., Andrade, Cristhianne M. R., Pereira, Loren Q., Simão, Guilherme F., de Oliveira, Carlo J., Correia, Dalmo, Oliveira, Robson T. S., da Silva, Marcos V., Silva, Anielle C. A., Dantas, Noelio O., Rodrigues, Virmondes, Muñoz, Rodrigo A. A., Alves-Balvedi, Renata P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7460044/
https://www.ncbi.nlm.nih.gov/pubmed/32717832
http://dx.doi.org/10.3390/bios10080081
_version_ 1783576510923276288
author Martins, Beatriz R.
Barbosa, Yanne O.
Andrade, Cristhianne M. R.
Pereira, Loren Q.
Simão, Guilherme F.
de Oliveira, Carlo J.
Correia, Dalmo
Oliveira, Robson T. S.
da Silva, Marcos V.
Silva, Anielle C. A.
Dantas, Noelio O.
Rodrigues, Virmondes
Muñoz, Rodrigo A. A.
Alves-Balvedi, Renata P.
author_facet Martins, Beatriz R.
Barbosa, Yanne O.
Andrade, Cristhianne M. R.
Pereira, Loren Q.
Simão, Guilherme F.
de Oliveira, Carlo J.
Correia, Dalmo
Oliveira, Robson T. S.
da Silva, Marcos V.
Silva, Anielle C. A.
Dantas, Noelio O.
Rodrigues, Virmondes
Muñoz, Rodrigo A. A.
Alves-Balvedi, Renata P.
author_sort Martins, Beatriz R.
collection PubMed
description Visceral leishmaniasis is a reemerging neglected tropical disease with limitations for its diagnosis, including low concentration of antibodies in the serum of asymptomatic patients and cross-reactions. In this context, this work proposes an electrochemical immunosensor for the diagnosis of visceral leishmaniasis in a more sensitive way that is capable of avoiding cross-reaction with Chagas disease (CD). Crude Leishmania infantum antigens tested in the enzyme-linked immunosorbent assay (ELISA) were methodologically standardized to best engage to the sensor. The antibodies anti-Trypanosoma cruzi and anti-Leishmania sp. Present in serum from patients with diverse types of CD or leishmaniasis were chosen. A screen-printed carbon electrode modified with gold nanoparticles was the best platform to guarantee effective adsorption of all antigens so that the epitope of specific recognition for leishmaniasis occurred efficiently and without cross-reaction with the evaluated CD. The current peaks reduced linearly after the recognition, and still were able to notice the discrimination between different kinds of diseases (digestive, cardiac, undetermined Chagas/acute and visceral chronic leishmaniasis). Comparative analyses with ELISA were performed with the same groups, and a low specificity (44%) was verified due to cross-reactions (high number of false positives) on ELISA tests, while the proposed immunosensor presented high selectivity and specificity (100%) without any false positives or false negatives for the serum samples from isolated patients with different types of CD and visceral leishmaniasis. Furthermore, the biosensor was stable for 5 days and presented a detection limit of 200 ng mL(−1).
format Online
Article
Text
id pubmed-7460044
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-74600442020-09-02 Development of an Electrochemical Immunosensor for Specific Detection of Visceral Leishmaniasis Using Gold-Modified Screen-Printed Carbon Electrodes Martins, Beatriz R. Barbosa, Yanne O. Andrade, Cristhianne M. R. Pereira, Loren Q. Simão, Guilherme F. de Oliveira, Carlo J. Correia, Dalmo Oliveira, Robson T. S. da Silva, Marcos V. Silva, Anielle C. A. Dantas, Noelio O. Rodrigues, Virmondes Muñoz, Rodrigo A. A. Alves-Balvedi, Renata P. Biosensors (Basel) Article Visceral leishmaniasis is a reemerging neglected tropical disease with limitations for its diagnosis, including low concentration of antibodies in the serum of asymptomatic patients and cross-reactions. In this context, this work proposes an electrochemical immunosensor for the diagnosis of visceral leishmaniasis in a more sensitive way that is capable of avoiding cross-reaction with Chagas disease (CD). Crude Leishmania infantum antigens tested in the enzyme-linked immunosorbent assay (ELISA) were methodologically standardized to best engage to the sensor. The antibodies anti-Trypanosoma cruzi and anti-Leishmania sp. Present in serum from patients with diverse types of CD or leishmaniasis were chosen. A screen-printed carbon electrode modified with gold nanoparticles was the best platform to guarantee effective adsorption of all antigens so that the epitope of specific recognition for leishmaniasis occurred efficiently and without cross-reaction with the evaluated CD. The current peaks reduced linearly after the recognition, and still were able to notice the discrimination between different kinds of diseases (digestive, cardiac, undetermined Chagas/acute and visceral chronic leishmaniasis). Comparative analyses with ELISA were performed with the same groups, and a low specificity (44%) was verified due to cross-reactions (high number of false positives) on ELISA tests, while the proposed immunosensor presented high selectivity and specificity (100%) without any false positives or false negatives for the serum samples from isolated patients with different types of CD and visceral leishmaniasis. Furthermore, the biosensor was stable for 5 days and presented a detection limit of 200 ng mL(−1). MDPI 2020-07-23 /pmc/articles/PMC7460044/ /pubmed/32717832 http://dx.doi.org/10.3390/bios10080081 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Martins, Beatriz R.
Barbosa, Yanne O.
Andrade, Cristhianne M. R.
Pereira, Loren Q.
Simão, Guilherme F.
de Oliveira, Carlo J.
Correia, Dalmo
Oliveira, Robson T. S.
da Silva, Marcos V.
Silva, Anielle C. A.
Dantas, Noelio O.
Rodrigues, Virmondes
Muñoz, Rodrigo A. A.
Alves-Balvedi, Renata P.
Development of an Electrochemical Immunosensor for Specific Detection of Visceral Leishmaniasis Using Gold-Modified Screen-Printed Carbon Electrodes
title Development of an Electrochemical Immunosensor for Specific Detection of Visceral Leishmaniasis Using Gold-Modified Screen-Printed Carbon Electrodes
title_full Development of an Electrochemical Immunosensor for Specific Detection of Visceral Leishmaniasis Using Gold-Modified Screen-Printed Carbon Electrodes
title_fullStr Development of an Electrochemical Immunosensor for Specific Detection of Visceral Leishmaniasis Using Gold-Modified Screen-Printed Carbon Electrodes
title_full_unstemmed Development of an Electrochemical Immunosensor for Specific Detection of Visceral Leishmaniasis Using Gold-Modified Screen-Printed Carbon Electrodes
title_short Development of an Electrochemical Immunosensor for Specific Detection of Visceral Leishmaniasis Using Gold-Modified Screen-Printed Carbon Electrodes
title_sort development of an electrochemical immunosensor for specific detection of visceral leishmaniasis using gold-modified screen-printed carbon electrodes
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7460044/
https://www.ncbi.nlm.nih.gov/pubmed/32717832
http://dx.doi.org/10.3390/bios10080081
work_keys_str_mv AT martinsbeatrizr developmentofanelectrochemicalimmunosensorforspecificdetectionofvisceralleishmaniasisusinggoldmodifiedscreenprintedcarbonelectrodes
AT barbosayanneo developmentofanelectrochemicalimmunosensorforspecificdetectionofvisceralleishmaniasisusinggoldmodifiedscreenprintedcarbonelectrodes
AT andradecristhiannemr developmentofanelectrochemicalimmunosensorforspecificdetectionofvisceralleishmaniasisusinggoldmodifiedscreenprintedcarbonelectrodes
AT pereiralorenq developmentofanelectrochemicalimmunosensorforspecificdetectionofvisceralleishmaniasisusinggoldmodifiedscreenprintedcarbonelectrodes
AT simaoguilhermef developmentofanelectrochemicalimmunosensorforspecificdetectionofvisceralleishmaniasisusinggoldmodifiedscreenprintedcarbonelectrodes
AT deoliveiracarloj developmentofanelectrochemicalimmunosensorforspecificdetectionofvisceralleishmaniasisusinggoldmodifiedscreenprintedcarbonelectrodes
AT correiadalmo developmentofanelectrochemicalimmunosensorforspecificdetectionofvisceralleishmaniasisusinggoldmodifiedscreenprintedcarbonelectrodes
AT oliveirarobsonts developmentofanelectrochemicalimmunosensorforspecificdetectionofvisceralleishmaniasisusinggoldmodifiedscreenprintedcarbonelectrodes
AT dasilvamarcosv developmentofanelectrochemicalimmunosensorforspecificdetectionofvisceralleishmaniasisusinggoldmodifiedscreenprintedcarbonelectrodes
AT silvaanielleca developmentofanelectrochemicalimmunosensorforspecificdetectionofvisceralleishmaniasisusinggoldmodifiedscreenprintedcarbonelectrodes
AT dantasnoelioo developmentofanelectrochemicalimmunosensorforspecificdetectionofvisceralleishmaniasisusinggoldmodifiedscreenprintedcarbonelectrodes
AT rodriguesvirmondes developmentofanelectrochemicalimmunosensorforspecificdetectionofvisceralleishmaniasisusinggoldmodifiedscreenprintedcarbonelectrodes
AT munozrodrigoaa developmentofanelectrochemicalimmunosensorforspecificdetectionofvisceralleishmaniasisusinggoldmodifiedscreenprintedcarbonelectrodes
AT alvesbalvedirenatap developmentofanelectrochemicalimmunosensorforspecificdetectionofvisceralleishmaniasisusinggoldmodifiedscreenprintedcarbonelectrodes