Cargando…
A Sensor Fusion Approach to the Estimation of Instantaneous Velocity Using Single Wearable Sensor During Sprint
Power-Force-Velocity profile obtained during a sprint test is crucial for designing personalized training and evaluating injury risks. Estimation of instantaneous velocity is requisite for developing these profiles and the predominant method for this estimation assumes it to have a first order expon...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7461787/ https://www.ncbi.nlm.nih.gov/pubmed/33014992 http://dx.doi.org/10.3389/fbioe.2020.00838 |
_version_ | 1783576789562425344 |
---|---|
author | Apte, Salil Meyer, Frederic Gremeaux, Vincent Dadashi, Farzin Aminian, Kamiar |
author_facet | Apte, Salil Meyer, Frederic Gremeaux, Vincent Dadashi, Farzin Aminian, Kamiar |
author_sort | Apte, Salil |
collection | PubMed |
description | Power-Force-Velocity profile obtained during a sprint test is crucial for designing personalized training and evaluating injury risks. Estimation of instantaneous velocity is requisite for developing these profiles and the predominant method for this estimation assumes it to have a first order exponential behavior. While this method remains appropriate for maximal sprints, the sprint velocity profile may not always show a first-order exponential behavior. Alternately, velocity profile has been estimated using inertial sensors, with a speed radar, or a smartphone application. Existing methods either relied on the exponential behavior or timing gates for drift removal, or estimated only the mean velocity. Thus, there is a need for a more flexible and appropriate approach, allowing for instantaneous velocity estimation during sprint tests. The proposed method aims to solve this problem using a sensor fusion approach, by combining the signals from wearable Global Navigation Satellite System (GNSS) and inertial measurement unit (IMU) sensors. We collected data from nine elite sprinters, equipped with a wearable GNSS-IMU sensor, who ran two trials each of 60 and 30/40 m sprints. We developed an algorithm using a gradient descent-based orientation filter, which simplified our model to a linear one-dimensional model, thus allowing us to use a simple Kalman filter (KF) for velocity estimation. We used two cascaded KFs, to segment the sprint data precisely, and to estimate the velocity and the sprint duration, respectively. We validated the estimated velocity and duration with speed radar and photocell data as reference. The median RMS error for the estimated velocity ranged from 6 to 8%, while that for the estimated sprint duration lied between 0.1 and −6.0%. The Bland–Altman plot showed close agreement between the estimated and the reference values of maximum velocity. Examination of fitting errors indicated a second order exponential behavior for the sprint velocity profile, unlike the first order behavior previously suggested in literature. The proposed sensor-fusion algorithm is valid to compute an accurate velocity profile with respect to the radar; it can compensate for and improve upon the accuracy of the individual IMU and GNSS velocities. This method thus enables the use of wearable sensors in the analysis of sprint test. |
format | Online Article Text |
id | pubmed-7461787 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-74617872020-10-01 A Sensor Fusion Approach to the Estimation of Instantaneous Velocity Using Single Wearable Sensor During Sprint Apte, Salil Meyer, Frederic Gremeaux, Vincent Dadashi, Farzin Aminian, Kamiar Front Bioeng Biotechnol Bioengineering and Biotechnology Power-Force-Velocity profile obtained during a sprint test is crucial for designing personalized training and evaluating injury risks. Estimation of instantaneous velocity is requisite for developing these profiles and the predominant method for this estimation assumes it to have a first order exponential behavior. While this method remains appropriate for maximal sprints, the sprint velocity profile may not always show a first-order exponential behavior. Alternately, velocity profile has been estimated using inertial sensors, with a speed radar, or a smartphone application. Existing methods either relied on the exponential behavior or timing gates for drift removal, or estimated only the mean velocity. Thus, there is a need for a more flexible and appropriate approach, allowing for instantaneous velocity estimation during sprint tests. The proposed method aims to solve this problem using a sensor fusion approach, by combining the signals from wearable Global Navigation Satellite System (GNSS) and inertial measurement unit (IMU) sensors. We collected data from nine elite sprinters, equipped with a wearable GNSS-IMU sensor, who ran two trials each of 60 and 30/40 m sprints. We developed an algorithm using a gradient descent-based orientation filter, which simplified our model to a linear one-dimensional model, thus allowing us to use a simple Kalman filter (KF) for velocity estimation. We used two cascaded KFs, to segment the sprint data precisely, and to estimate the velocity and the sprint duration, respectively. We validated the estimated velocity and duration with speed radar and photocell data as reference. The median RMS error for the estimated velocity ranged from 6 to 8%, while that for the estimated sprint duration lied between 0.1 and −6.0%. The Bland–Altman plot showed close agreement between the estimated and the reference values of maximum velocity. Examination of fitting errors indicated a second order exponential behavior for the sprint velocity profile, unlike the first order behavior previously suggested in literature. The proposed sensor-fusion algorithm is valid to compute an accurate velocity profile with respect to the radar; it can compensate for and improve upon the accuracy of the individual IMU and GNSS velocities. This method thus enables the use of wearable sensors in the analysis of sprint test. Frontiers Media S.A. 2020-08-18 /pmc/articles/PMC7461787/ /pubmed/33014992 http://dx.doi.org/10.3389/fbioe.2020.00838 Text en Copyright © 2020 Apte, Meyer, Gremeaux, Dadashi and Aminian. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Bioengineering and Biotechnology Apte, Salil Meyer, Frederic Gremeaux, Vincent Dadashi, Farzin Aminian, Kamiar A Sensor Fusion Approach to the Estimation of Instantaneous Velocity Using Single Wearable Sensor During Sprint |
title | A Sensor Fusion Approach to the Estimation of Instantaneous Velocity Using Single Wearable Sensor During Sprint |
title_full | A Sensor Fusion Approach to the Estimation of Instantaneous Velocity Using Single Wearable Sensor During Sprint |
title_fullStr | A Sensor Fusion Approach to the Estimation of Instantaneous Velocity Using Single Wearable Sensor During Sprint |
title_full_unstemmed | A Sensor Fusion Approach to the Estimation of Instantaneous Velocity Using Single Wearable Sensor During Sprint |
title_short | A Sensor Fusion Approach to the Estimation of Instantaneous Velocity Using Single Wearable Sensor During Sprint |
title_sort | sensor fusion approach to the estimation of instantaneous velocity using single wearable sensor during sprint |
topic | Bioengineering and Biotechnology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7461787/ https://www.ncbi.nlm.nih.gov/pubmed/33014992 http://dx.doi.org/10.3389/fbioe.2020.00838 |
work_keys_str_mv | AT aptesalil asensorfusionapproachtotheestimationofinstantaneousvelocityusingsinglewearablesensorduringsprint AT meyerfrederic asensorfusionapproachtotheestimationofinstantaneousvelocityusingsinglewearablesensorduringsprint AT gremeauxvincent asensorfusionapproachtotheestimationofinstantaneousvelocityusingsinglewearablesensorduringsprint AT dadashifarzin asensorfusionapproachtotheestimationofinstantaneousvelocityusingsinglewearablesensorduringsprint AT aminiankamiar asensorfusionapproachtotheestimationofinstantaneousvelocityusingsinglewearablesensorduringsprint AT aptesalil sensorfusionapproachtotheestimationofinstantaneousvelocityusingsinglewearablesensorduringsprint AT meyerfrederic sensorfusionapproachtotheestimationofinstantaneousvelocityusingsinglewearablesensorduringsprint AT gremeauxvincent sensorfusionapproachtotheestimationofinstantaneousvelocityusingsinglewearablesensorduringsprint AT dadashifarzin sensorfusionapproachtotheestimationofinstantaneousvelocityusingsinglewearablesensorduringsprint AT aminiankamiar sensorfusionapproachtotheestimationofinstantaneousvelocityusingsinglewearablesensorduringsprint |