Cargando…

Relationship between the morphological, mechanical and permeability properties of porous bone scaffolds and the underlying microstructure

Bone scaffolds are widely used as one of the main bone substitute materials. However, many bone scaffold microstructure topologies exist and it is still unclear which topology to use when designing scaffold for a specific application. The aim of the present study was to reveal the mechanism of the m...

Descripción completa

Detalles Bibliográficos
Autores principales: Lu, Yongtao, Cheng, LiangLiang, Yang, Zhuoyue, Li, Junyan, Zhu, Hanxing
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7462274/
https://www.ncbi.nlm.nih.gov/pubmed/32870933
http://dx.doi.org/10.1371/journal.pone.0238471
_version_ 1783576884790951936
author Lu, Yongtao
Cheng, LiangLiang
Yang, Zhuoyue
Li, Junyan
Zhu, Hanxing
author_facet Lu, Yongtao
Cheng, LiangLiang
Yang, Zhuoyue
Li, Junyan
Zhu, Hanxing
author_sort Lu, Yongtao
collection PubMed
description Bone scaffolds are widely used as one of the main bone substitute materials. However, many bone scaffold microstructure topologies exist and it is still unclear which topology to use when designing scaffold for a specific application. The aim of the present study was to reveal the mechanism of the microstructure-driven performance of bone scaffold and thus to provide guideline on scaffold design. Finite element (FE) models of five TPMS (Diamond, Gyroid, Schwarz P, Fischer-Koch S and F-RD) and three traditional (Cube, FD-Cube and Octa) scaffolds were generated. The effective compressive and shear moduli of scaffolds were calculated from the mechanical analysis using the FE unit cell models with the periodic boundary condition. The scaffold permeability was calculated from the computational fluid dynamics (CFD) analysis using the 4×4×4 FE models. It is revealed that the surface-to-volume ratio of the Fischer-Koch S-based scaffold is the highest among the scaffolds investigated. The mechanical analysis revealed that the bending deformation dominated structures (e.g., the Diamond, the Gyroid, the Schwarz P) have higher effective shear moduli. The stretching deformation dominated structures (e.g., the Schwarz P, the Cube) have higher effective compressive moduli. For all the scaffolds, when the same amount of change in scaffold porosity is made, the corresponding change in the scaffold relative shear modulus is larger than that in the relative compressive modulus. The CFD analysis revealed that the structures with the simple and straight pores (e.g., Cube) have higher permeability than the structures with the complex pores (e.g., Fischer-Koch S). The main contribution of the present study is that the relationship between scaffold properties and the underlying microstructure is systematically investigated and thus some guidelines on the design of bone scaffolds are provided, for example, in the scenario where a high surface-to-volume ratio is required, it is suggested to use the Fischer-Koch S based scaffold.
format Online
Article
Text
id pubmed-7462274
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-74622742020-09-04 Relationship between the morphological, mechanical and permeability properties of porous bone scaffolds and the underlying microstructure Lu, Yongtao Cheng, LiangLiang Yang, Zhuoyue Li, Junyan Zhu, Hanxing PLoS One Research Article Bone scaffolds are widely used as one of the main bone substitute materials. However, many bone scaffold microstructure topologies exist and it is still unclear which topology to use when designing scaffold for a specific application. The aim of the present study was to reveal the mechanism of the microstructure-driven performance of bone scaffold and thus to provide guideline on scaffold design. Finite element (FE) models of five TPMS (Diamond, Gyroid, Schwarz P, Fischer-Koch S and F-RD) and three traditional (Cube, FD-Cube and Octa) scaffolds were generated. The effective compressive and shear moduli of scaffolds were calculated from the mechanical analysis using the FE unit cell models with the periodic boundary condition. The scaffold permeability was calculated from the computational fluid dynamics (CFD) analysis using the 4×4×4 FE models. It is revealed that the surface-to-volume ratio of the Fischer-Koch S-based scaffold is the highest among the scaffolds investigated. The mechanical analysis revealed that the bending deformation dominated structures (e.g., the Diamond, the Gyroid, the Schwarz P) have higher effective shear moduli. The stretching deformation dominated structures (e.g., the Schwarz P, the Cube) have higher effective compressive moduli. For all the scaffolds, when the same amount of change in scaffold porosity is made, the corresponding change in the scaffold relative shear modulus is larger than that in the relative compressive modulus. The CFD analysis revealed that the structures with the simple and straight pores (e.g., Cube) have higher permeability than the structures with the complex pores (e.g., Fischer-Koch S). The main contribution of the present study is that the relationship between scaffold properties and the underlying microstructure is systematically investigated and thus some guidelines on the design of bone scaffolds are provided, for example, in the scenario where a high surface-to-volume ratio is required, it is suggested to use the Fischer-Koch S based scaffold. Public Library of Science 2020-09-01 /pmc/articles/PMC7462274/ /pubmed/32870933 http://dx.doi.org/10.1371/journal.pone.0238471 Text en © 2020 Lu et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Lu, Yongtao
Cheng, LiangLiang
Yang, Zhuoyue
Li, Junyan
Zhu, Hanxing
Relationship between the morphological, mechanical and permeability properties of porous bone scaffolds and the underlying microstructure
title Relationship between the morphological, mechanical and permeability properties of porous bone scaffolds and the underlying microstructure
title_full Relationship between the morphological, mechanical and permeability properties of porous bone scaffolds and the underlying microstructure
title_fullStr Relationship between the morphological, mechanical and permeability properties of porous bone scaffolds and the underlying microstructure
title_full_unstemmed Relationship between the morphological, mechanical and permeability properties of porous bone scaffolds and the underlying microstructure
title_short Relationship between the morphological, mechanical and permeability properties of porous bone scaffolds and the underlying microstructure
title_sort relationship between the morphological, mechanical and permeability properties of porous bone scaffolds and the underlying microstructure
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7462274/
https://www.ncbi.nlm.nih.gov/pubmed/32870933
http://dx.doi.org/10.1371/journal.pone.0238471
work_keys_str_mv AT luyongtao relationshipbetweenthemorphologicalmechanicalandpermeabilitypropertiesofporousbonescaffoldsandtheunderlyingmicrostructure
AT chengliangliang relationshipbetweenthemorphologicalmechanicalandpermeabilitypropertiesofporousbonescaffoldsandtheunderlyingmicrostructure
AT yangzhuoyue relationshipbetweenthemorphologicalmechanicalandpermeabilitypropertiesofporousbonescaffoldsandtheunderlyingmicrostructure
AT lijunyan relationshipbetweenthemorphologicalmechanicalandpermeabilitypropertiesofporousbonescaffoldsandtheunderlyingmicrostructure
AT zhuhanxing relationshipbetweenthemorphologicalmechanicalandpermeabilitypropertiesofporousbonescaffoldsandtheunderlyingmicrostructure