OBJECTIVE: To compare the utility and diagnostic performance of automated breast ultrasound system (ABUS) with that of hand-held ultrasound (HHUS) in evaluating pure non-mass enhancement (NME) lesions on breast magnetic resonance imaging (MRI). MATERIALS AND METHODS: One hundred twenty-six consecuti...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Radiology
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7462763/ https://www.ncbi.nlm.nih.gov/pubmed/32729267 http://dx.doi.org/10.3348/kjr.2019.0881 |
_version_ | 1783576985014894592 |
---|---|
author | Kwon, Bo Ra Chang, Jung Min Kim, Soo-Yeon Lee, Su Hyun Shin, Sung Ui Yi, Ann Cho, Nariya Moon, Woo Kyung |
author_facet | Kwon, Bo Ra Chang, Jung Min Kim, Soo-Yeon Lee, Su Hyun Shin, Sung Ui Yi, Ann Cho, Nariya Moon, Woo Kyung |
author_sort | Kwon, Bo Ra |
collection | PubMed |
description | OBJECTIVE: To compare the utility and diagnostic performance of automated breast ultrasound system (ABUS) with that of hand-held ultrasound (HHUS) in evaluating pure non-mass enhancement (NME) lesions on breast magnetic resonance imaging (MRI). MATERIALS AND METHODS: One hundred twenty-six consecutive MRI-visible pure NME lesions of 122 patients with breast cancer were assessed from April 2016 to March 2017. Two radiologists reviewed the preoperative breast MRI, ABUS, and HHUS images along with mammography (MG) findings. The NME correlation rate and diagnostic performance of ABUS were compared with that of HHUS, and the imaging features associated with ABUS visibility were analyzed. RESULTS: Among 126 pure NME lesions, 100 (79.4%) were malignant and 26 (20.6%) were benign. The overall correlation rate was 87.3% (110/126) in ABUS and 92.9% (117/126) in HHUS. The sensitivity and specificity were 87% and 50% for ABUS and 92% and 42.3% for HHUS, respectively, with no significant differences (p = 0.180 and 0.727, respectively). Malignant NME was more frequently visualized than benign NME lesions on ABUS (93% vs. 65.4%, p = 0.001). Significant factors associated with the visibility of ABUS were the size of NME lesions on MRI (p < 0.001), their distribution pattern (p < 0.001), and microcalcifications on MG (p = 0.027). CONCLUSION: ABUS evaluation of pure NME lesions on MRI in patients with breast cancer is a useful technique with high visibility, especially in malignant lesions. The diagnostic performance of ABUS was comparable with that of conventional HHUS in evaluating NME lesions. |
format | Online Article Text |
id | pubmed-7462763 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | The Korean Society of Radiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-74627632020-11-01 Utility and Diagnostic Performance of Automated Breast Ultrasound System in Evaluating Pure Non-Mass Enhancement on Breast Magnetic Resonance Imaging Kwon, Bo Ra Chang, Jung Min Kim, Soo-Yeon Lee, Su Hyun Shin, Sung Ui Yi, Ann Cho, Nariya Moon, Woo Kyung Korean J Radiol Breast Imaging OBJECTIVE: To compare the utility and diagnostic performance of automated breast ultrasound system (ABUS) with that of hand-held ultrasound (HHUS) in evaluating pure non-mass enhancement (NME) lesions on breast magnetic resonance imaging (MRI). MATERIALS AND METHODS: One hundred twenty-six consecutive MRI-visible pure NME lesions of 122 patients with breast cancer were assessed from April 2016 to March 2017. Two radiologists reviewed the preoperative breast MRI, ABUS, and HHUS images along with mammography (MG) findings. The NME correlation rate and diagnostic performance of ABUS were compared with that of HHUS, and the imaging features associated with ABUS visibility were analyzed. RESULTS: Among 126 pure NME lesions, 100 (79.4%) were malignant and 26 (20.6%) were benign. The overall correlation rate was 87.3% (110/126) in ABUS and 92.9% (117/126) in HHUS. The sensitivity and specificity were 87% and 50% for ABUS and 92% and 42.3% for HHUS, respectively, with no significant differences (p = 0.180 and 0.727, respectively). Malignant NME was more frequently visualized than benign NME lesions on ABUS (93% vs. 65.4%, p = 0.001). Significant factors associated with the visibility of ABUS were the size of NME lesions on MRI (p < 0.001), their distribution pattern (p < 0.001), and microcalcifications on MG (p = 0.027). CONCLUSION: ABUS evaluation of pure NME lesions on MRI in patients with breast cancer is a useful technique with high visibility, especially in malignant lesions. The diagnostic performance of ABUS was comparable with that of conventional HHUS in evaluating NME lesions. The Korean Society of Radiology 2020-11 2020-07-22 /pmc/articles/PMC7462763/ /pubmed/32729267 http://dx.doi.org/10.3348/kjr.2019.0881 Text en Copyright © 2020 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Breast Imaging Kwon, Bo Ra Chang, Jung Min Kim, Soo-Yeon Lee, Su Hyun Shin, Sung Ui Yi, Ann Cho, Nariya Moon, Woo Kyung Utility and Diagnostic Performance of Automated Breast Ultrasound System in Evaluating Pure Non-Mass Enhancement on Breast Magnetic Resonance Imaging |
title | Utility and Diagnostic Performance of Automated Breast Ultrasound System in Evaluating Pure Non-Mass Enhancement on Breast Magnetic Resonance Imaging |
title_full | Utility and Diagnostic Performance of Automated Breast Ultrasound System in Evaluating Pure Non-Mass Enhancement on Breast Magnetic Resonance Imaging |
title_fullStr | Utility and Diagnostic Performance of Automated Breast Ultrasound System in Evaluating Pure Non-Mass Enhancement on Breast Magnetic Resonance Imaging |
title_full_unstemmed | Utility and Diagnostic Performance of Automated Breast Ultrasound System in Evaluating Pure Non-Mass Enhancement on Breast Magnetic Resonance Imaging |
title_short | Utility and Diagnostic Performance of Automated Breast Ultrasound System in Evaluating Pure Non-Mass Enhancement on Breast Magnetic Resonance Imaging |
title_sort | utility and diagnostic performance of automated breast ultrasound system in evaluating pure non-mass enhancement on breast magnetic resonance imaging |
topic | Breast Imaging |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7462763/ https://www.ncbi.nlm.nih.gov/pubmed/32729267 http://dx.doi.org/10.3348/kjr.2019.0881 |
work_keys_str_mv | AT kwonbora utilityanddiagnosticperformanceofautomatedbreastultrasoundsysteminevaluatingpurenonmassenhancementonbreastmagneticresonanceimaging AT changjungmin utilityanddiagnosticperformanceofautomatedbreastultrasoundsysteminevaluatingpurenonmassenhancementonbreastmagneticresonanceimaging AT kimsooyeon utilityanddiagnosticperformanceofautomatedbreastultrasoundsysteminevaluatingpurenonmassenhancementonbreastmagneticresonanceimaging AT leesuhyun utilityanddiagnosticperformanceofautomatedbreastultrasoundsysteminevaluatingpurenonmassenhancementonbreastmagneticresonanceimaging AT shinsungui utilityanddiagnosticperformanceofautomatedbreastultrasoundsysteminevaluatingpurenonmassenhancementonbreastmagneticresonanceimaging AT yiann utilityanddiagnosticperformanceofautomatedbreastultrasoundsysteminevaluatingpurenonmassenhancementonbreastmagneticresonanceimaging AT chonariya utilityanddiagnosticperformanceofautomatedbreastultrasoundsysteminevaluatingpurenonmassenhancementonbreastmagneticresonanceimaging AT moonwookyung utilityanddiagnosticperformanceofautomatedbreastultrasoundsysteminevaluatingpurenonmassenhancementonbreastmagneticresonanceimaging |