Cargando…

Photogrammetry-based stereoscopic optode registration method for functional near-infrared spectroscopy

Significance: Functional near-infrared spectroscopy (fNIRS) is an emerging brain imaging technique due to its small size, low cost, minimum scanning sonic noise, and portability. Unfortunately, because this technique does not provide neuroanatomical information to accompany the functional data, its...

Descripción completa

Detalles Bibliográficos
Autores principales: Hu, Xiao-Su, Wagley, Neelima, Rioboo, Akemi Tsutsumi, DaSilva, Alexandre F., Kovelman, Ioulia
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Society of Photo-Optical Instrumentation Engineers 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7463164/
https://www.ncbi.nlm.nih.gov/pubmed/32880124
http://dx.doi.org/10.1117/1.JBO.25.9.095001
_version_ 1783577072488153088
author Hu, Xiao-Su
Wagley, Neelima
Rioboo, Akemi Tsutsumi
DaSilva, Alexandre F.
Kovelman, Ioulia
author_facet Hu, Xiao-Su
Wagley, Neelima
Rioboo, Akemi Tsutsumi
DaSilva, Alexandre F.
Kovelman, Ioulia
author_sort Hu, Xiao-Su
collection PubMed
description Significance: Functional near-infrared spectroscopy (fNIRS) is an emerging brain imaging technique due to its small size, low cost, minimum scanning sonic noise, and portability. Unfortunately, because this technique does not provide neuroanatomical information to accompany the functional data, its data interpretation remains a persistent challenge in fNIRS brain imaging applications. The two most popular approaches for fNIRS anatomical registration are magnetic resonance imaging (MRI) and three-dimensional (3-D) digitization. MRI scanning yields high-precision registration but reduces the cost-effectiveness and accessibility of fNIRS imaging. Alternatively, the low cost and portable 3-D digitizers are affected by magnetic properties of ambient metal objects, including participant clothing, testing equipment, medical implants, and so forth. Aim: To overcome these obstacles and provide accessible and reliable neuroanatomical registration for fNIRS imaging, we developed and explored a photogrammetry optode registration (POR) method. Approach: The POR method uses a consumer-grade camera to reconstruct a 3-D image of the fNIRS optode-set, including light emitters and detectors, on a participant’s head. This reconstruction process uses a linear-time incremental structure from motion (LTI-SfM) algorithm, based on 100 to 150 digital photos. The POR method then aligns the reconstructed image with an anatomical template of the brain. Results: To validate this method, we tested 22 adult and 19 child participants using the POR method and MRI imaging. The results comparisons suggest on average 55% and 46% overlap across all data channel measurements registered by the two methods in adult and children, respectively. Importantly, this overlap reached 65% and 60% in only the frontal channels. Conclusions: These results suggested that the mismatch in registration was partially due to higher variation in backward optode placement rather than the registration efficacy. Therefore, the photo-based registration method can offer an accessible and reliable approach to neuroanatomical registration of fNIRS as well as other surface-based neuroimaging and neuromodulation methods.
format Online
Article
Text
id pubmed-7463164
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Society of Photo-Optical Instrumentation Engineers
record_format MEDLINE/PubMed
spelling pubmed-74631642020-09-03 Photogrammetry-based stereoscopic optode registration method for functional near-infrared spectroscopy Hu, Xiao-Su Wagley, Neelima Rioboo, Akemi Tsutsumi DaSilva, Alexandre F. Kovelman, Ioulia J Biomed Opt General Significance: Functional near-infrared spectroscopy (fNIRS) is an emerging brain imaging technique due to its small size, low cost, minimum scanning sonic noise, and portability. Unfortunately, because this technique does not provide neuroanatomical information to accompany the functional data, its data interpretation remains a persistent challenge in fNIRS brain imaging applications. The two most popular approaches for fNIRS anatomical registration are magnetic resonance imaging (MRI) and three-dimensional (3-D) digitization. MRI scanning yields high-precision registration but reduces the cost-effectiveness and accessibility of fNIRS imaging. Alternatively, the low cost and portable 3-D digitizers are affected by magnetic properties of ambient metal objects, including participant clothing, testing equipment, medical implants, and so forth. Aim: To overcome these obstacles and provide accessible and reliable neuroanatomical registration for fNIRS imaging, we developed and explored a photogrammetry optode registration (POR) method. Approach: The POR method uses a consumer-grade camera to reconstruct a 3-D image of the fNIRS optode-set, including light emitters and detectors, on a participant’s head. This reconstruction process uses a linear-time incremental structure from motion (LTI-SfM) algorithm, based on 100 to 150 digital photos. The POR method then aligns the reconstructed image with an anatomical template of the brain. Results: To validate this method, we tested 22 adult and 19 child participants using the POR method and MRI imaging. The results comparisons suggest on average 55% and 46% overlap across all data channel measurements registered by the two methods in adult and children, respectively. Importantly, this overlap reached 65% and 60% in only the frontal channels. Conclusions: These results suggested that the mismatch in registration was partially due to higher variation in backward optode placement rather than the registration efficacy. Therefore, the photo-based registration method can offer an accessible and reliable approach to neuroanatomical registration of fNIRS as well as other surface-based neuroimaging and neuromodulation methods. Society of Photo-Optical Instrumentation Engineers 2020-09-02 2020-09 /pmc/articles/PMC7463164/ /pubmed/32880124 http://dx.doi.org/10.1117/1.JBO.25.9.095001 Text en © 2020 The Authors https://creativecommons.org/licenses/by/4.0/ Published by SPIE under a Creative Commons Attribution 4.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.
spellingShingle General
Hu, Xiao-Su
Wagley, Neelima
Rioboo, Akemi Tsutsumi
DaSilva, Alexandre F.
Kovelman, Ioulia
Photogrammetry-based stereoscopic optode registration method for functional near-infrared spectroscopy
title Photogrammetry-based stereoscopic optode registration method for functional near-infrared spectroscopy
title_full Photogrammetry-based stereoscopic optode registration method for functional near-infrared spectroscopy
title_fullStr Photogrammetry-based stereoscopic optode registration method for functional near-infrared spectroscopy
title_full_unstemmed Photogrammetry-based stereoscopic optode registration method for functional near-infrared spectroscopy
title_short Photogrammetry-based stereoscopic optode registration method for functional near-infrared spectroscopy
title_sort photogrammetry-based stereoscopic optode registration method for functional near-infrared spectroscopy
topic General
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7463164/
https://www.ncbi.nlm.nih.gov/pubmed/32880124
http://dx.doi.org/10.1117/1.JBO.25.9.095001
work_keys_str_mv AT huxiaosu photogrammetrybasedstereoscopicoptoderegistrationmethodforfunctionalnearinfraredspectroscopy
AT wagleyneelima photogrammetrybasedstereoscopicoptoderegistrationmethodforfunctionalnearinfraredspectroscopy
AT riobooakemitsutsumi photogrammetrybasedstereoscopicoptoderegistrationmethodforfunctionalnearinfraredspectroscopy
AT dasilvaalexandref photogrammetrybasedstereoscopicoptoderegistrationmethodforfunctionalnearinfraredspectroscopy
AT kovelmanioulia photogrammetrybasedstereoscopicoptoderegistrationmethodforfunctionalnearinfraredspectroscopy