Cargando…

Influence of Implant Connection, Abutment Design and Screw Insertion Torque on Implant-Abutment Misfit

Background: An accurate fit at the implant-abutment interface is an important factor to avoid biological and mechanical complications. The aim of this study was to evaluate the marginal misfit at the implant-abutment interface on external and Morse taper connection, with straight and angulated abutm...

Descripción completa

Detalles Bibliográficos
Autores principales: Vélez, Jorge, Peláez, Jesús, López-Suárez, Carlos, Agustín-Panadero, Rubén, Tobar, Celia, Suárez, María J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7463581/
https://www.ncbi.nlm.nih.gov/pubmed/32722131
http://dx.doi.org/10.3390/jcm9082365
_version_ 1783577165135085568
author Vélez, Jorge
Peláez, Jesús
López-Suárez, Carlos
Agustín-Panadero, Rubén
Tobar, Celia
Suárez, María J.
author_facet Vélez, Jorge
Peláez, Jesús
López-Suárez, Carlos
Agustín-Panadero, Rubén
Tobar, Celia
Suárez, María J.
author_sort Vélez, Jorge
collection PubMed
description Background: An accurate fit at the implant-abutment interface is an important factor to avoid biological and mechanical complications. The aim of this study was to evaluate the marginal misfit at the implant-abutment interface on external and Morse taper connection, with straight and angulated abutments under different insertion torque loads. Materials and Methods: A total of 120 implants were used, 60 with external connection (EC) and 60 with Morse taper connection (IC). Straight (SA) (n = 60) and angulated abutments (AA) (n = 60) were randomly screwed to each connection at different torque levels (n = 10 each): 10, 20 and 30 Ncm. All specimens were subjected to thermal and cyclic loading and the misfit was measured by scanning electron microscopy. Data were analyzed with one-way ANOVA, t-test and Kruskal-Wallis test. Results: Significant differences (p < 0.001) were found between connections and abutments regardless of the torque applied. Morse taper connections with straight and angulated abutments showed the lowest misfit values (0.6 µm). Misfit values decreased as torque increased. Conclusions: The misfit was affected by the type of connection. The type of abutment did not influence the fit in the Morse taper connection. The higher the tightening torque applied the increase in the fit of the implant-abutment interface.
format Online
Article
Text
id pubmed-7463581
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-74635812020-09-02 Influence of Implant Connection, Abutment Design and Screw Insertion Torque on Implant-Abutment Misfit Vélez, Jorge Peláez, Jesús López-Suárez, Carlos Agustín-Panadero, Rubén Tobar, Celia Suárez, María J. J Clin Med Article Background: An accurate fit at the implant-abutment interface is an important factor to avoid biological and mechanical complications. The aim of this study was to evaluate the marginal misfit at the implant-abutment interface on external and Morse taper connection, with straight and angulated abutments under different insertion torque loads. Materials and Methods: A total of 120 implants were used, 60 with external connection (EC) and 60 with Morse taper connection (IC). Straight (SA) (n = 60) and angulated abutments (AA) (n = 60) were randomly screwed to each connection at different torque levels (n = 10 each): 10, 20 and 30 Ncm. All specimens were subjected to thermal and cyclic loading and the misfit was measured by scanning electron microscopy. Data were analyzed with one-way ANOVA, t-test and Kruskal-Wallis test. Results: Significant differences (p < 0.001) were found between connections and abutments regardless of the torque applied. Morse taper connections with straight and angulated abutments showed the lowest misfit values (0.6 µm). Misfit values decreased as torque increased. Conclusions: The misfit was affected by the type of connection. The type of abutment did not influence the fit in the Morse taper connection. The higher the tightening torque applied the increase in the fit of the implant-abutment interface. MDPI 2020-07-24 /pmc/articles/PMC7463581/ /pubmed/32722131 http://dx.doi.org/10.3390/jcm9082365 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Vélez, Jorge
Peláez, Jesús
López-Suárez, Carlos
Agustín-Panadero, Rubén
Tobar, Celia
Suárez, María J.
Influence of Implant Connection, Abutment Design and Screw Insertion Torque on Implant-Abutment Misfit
title Influence of Implant Connection, Abutment Design and Screw Insertion Torque on Implant-Abutment Misfit
title_full Influence of Implant Connection, Abutment Design and Screw Insertion Torque on Implant-Abutment Misfit
title_fullStr Influence of Implant Connection, Abutment Design and Screw Insertion Torque on Implant-Abutment Misfit
title_full_unstemmed Influence of Implant Connection, Abutment Design and Screw Insertion Torque on Implant-Abutment Misfit
title_short Influence of Implant Connection, Abutment Design and Screw Insertion Torque on Implant-Abutment Misfit
title_sort influence of implant connection, abutment design and screw insertion torque on implant-abutment misfit
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7463581/
https://www.ncbi.nlm.nih.gov/pubmed/32722131
http://dx.doi.org/10.3390/jcm9082365
work_keys_str_mv AT velezjorge influenceofimplantconnectionabutmentdesignandscrewinsertiontorqueonimplantabutmentmisfit
AT pelaezjesus influenceofimplantconnectionabutmentdesignandscrewinsertiontorqueonimplantabutmentmisfit
AT lopezsuarezcarlos influenceofimplantconnectionabutmentdesignandscrewinsertiontorqueonimplantabutmentmisfit
AT agustinpanaderoruben influenceofimplantconnectionabutmentdesignandscrewinsertiontorqueonimplantabutmentmisfit
AT tobarcelia influenceofimplantconnectionabutmentdesignandscrewinsertiontorqueonimplantabutmentmisfit
AT suarezmariaj influenceofimplantconnectionabutmentdesignandscrewinsertiontorqueonimplantabutmentmisfit