Cargando…

How Accurate Is Oral Implant Installation Using Surgical Guides Printed from a Degradable and Steam-Sterilized Biopolymer?

3D printed surgical guides are used for prosthetically-driven oral implant placement. When manufacturing these guides, information regarding suitable printing techniques and materials as well as the necessity for additional, non-printed stock parts such as metal sleeves is scarce. The aim of the inv...

Descripción completa

Detalles Bibliográficos
Autores principales: Pieralli, Stefano, Spies, Benedikt Christopher, Hromadnik, Valentin, Nicic, Robert, Beuer, Florian, Wesemann, Christian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7463912/
https://www.ncbi.nlm.nih.gov/pubmed/32707759
http://dx.doi.org/10.3390/jcm9082322
_version_ 1783577243133411328
author Pieralli, Stefano
Spies, Benedikt Christopher
Hromadnik, Valentin
Nicic, Robert
Beuer, Florian
Wesemann, Christian
author_facet Pieralli, Stefano
Spies, Benedikt Christopher
Hromadnik, Valentin
Nicic, Robert
Beuer, Florian
Wesemann, Christian
author_sort Pieralli, Stefano
collection PubMed
description 3D printed surgical guides are used for prosthetically-driven oral implant placement. When manufacturing these guides, information regarding suitable printing techniques and materials as well as the necessity for additional, non-printed stock parts such as metal sleeves is scarce. The aim of the investigation was to determine the accuracy of a surgical workflow for oral implant placement using guides manufactured by means of fused deposition modeling (FDM) from a biodegradable and sterilizable biopolymer filament. Furthermore, the potential benefit of metal sleeve inserts should be assessed. A surgical guide was designed for the installation of two implants in the region of the second premolar (SP) and second molar (SM) in a mandibular typodont model. For two additive manufacturing techniques (stereolithography [SLA]: reference group, FDM: observational group) n = 10 surgical guides, with (S) and without (NS) metal sleeves, were used. This resulted in 4 groups of 10 samples each (SLA-S/NS, FDM-S/NS). Target and real implant positions were superimposed and compared using a dedicated software. Sagittal, transversal, and vertical discrepancies at the level of the implant shoulder, apex and regarding the main axis were determined. MANOVA with posthoc Tukey tests were performed for statistical analyses. Placed implants showed sagittal and transversal discrepancies of <1 mm, vertical discrepancies of <0.6 mm, and axial deviations of ≤3°. In the vertical dimension, no differences between the four groups were measured (p ≤ 0.054). In the sagittal dimension, SLA groups showed decreased deviations in the implant shoulder region compared to FDM (p ≤ 0.033), whereas no differences in the transversal dimension between the groups were measured (p ≤ 0.054). The use of metal sleeves did not affect axial, vertical, and sagittal accuracy, but resulted in increased transversal deviations (p = 0.001). Regarding accuracy, biopolymer-based surgical guides manufactured by means of FDM present similar accuracy than SLA. Cytotoxicity tests are necessary to confirm their biocompatibility in the oral environment.
format Online
Article
Text
id pubmed-7463912
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-74639122020-09-04 How Accurate Is Oral Implant Installation Using Surgical Guides Printed from a Degradable and Steam-Sterilized Biopolymer? Pieralli, Stefano Spies, Benedikt Christopher Hromadnik, Valentin Nicic, Robert Beuer, Florian Wesemann, Christian J Clin Med Article 3D printed surgical guides are used for prosthetically-driven oral implant placement. When manufacturing these guides, information regarding suitable printing techniques and materials as well as the necessity for additional, non-printed stock parts such as metal sleeves is scarce. The aim of the investigation was to determine the accuracy of a surgical workflow for oral implant placement using guides manufactured by means of fused deposition modeling (FDM) from a biodegradable and sterilizable biopolymer filament. Furthermore, the potential benefit of metal sleeve inserts should be assessed. A surgical guide was designed for the installation of two implants in the region of the second premolar (SP) and second molar (SM) in a mandibular typodont model. For two additive manufacturing techniques (stereolithography [SLA]: reference group, FDM: observational group) n = 10 surgical guides, with (S) and without (NS) metal sleeves, were used. This resulted in 4 groups of 10 samples each (SLA-S/NS, FDM-S/NS). Target and real implant positions were superimposed and compared using a dedicated software. Sagittal, transversal, and vertical discrepancies at the level of the implant shoulder, apex and regarding the main axis were determined. MANOVA with posthoc Tukey tests were performed for statistical analyses. Placed implants showed sagittal and transversal discrepancies of <1 mm, vertical discrepancies of <0.6 mm, and axial deviations of ≤3°. In the vertical dimension, no differences between the four groups were measured (p ≤ 0.054). In the sagittal dimension, SLA groups showed decreased deviations in the implant shoulder region compared to FDM (p ≤ 0.033), whereas no differences in the transversal dimension between the groups were measured (p ≤ 0.054). The use of metal sleeves did not affect axial, vertical, and sagittal accuracy, but resulted in increased transversal deviations (p = 0.001). Regarding accuracy, biopolymer-based surgical guides manufactured by means of FDM present similar accuracy than SLA. Cytotoxicity tests are necessary to confirm their biocompatibility in the oral environment. MDPI 2020-07-22 /pmc/articles/PMC7463912/ /pubmed/32707759 http://dx.doi.org/10.3390/jcm9082322 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Pieralli, Stefano
Spies, Benedikt Christopher
Hromadnik, Valentin
Nicic, Robert
Beuer, Florian
Wesemann, Christian
How Accurate Is Oral Implant Installation Using Surgical Guides Printed from a Degradable and Steam-Sterilized Biopolymer?
title How Accurate Is Oral Implant Installation Using Surgical Guides Printed from a Degradable and Steam-Sterilized Biopolymer?
title_full How Accurate Is Oral Implant Installation Using Surgical Guides Printed from a Degradable and Steam-Sterilized Biopolymer?
title_fullStr How Accurate Is Oral Implant Installation Using Surgical Guides Printed from a Degradable and Steam-Sterilized Biopolymer?
title_full_unstemmed How Accurate Is Oral Implant Installation Using Surgical Guides Printed from a Degradable and Steam-Sterilized Biopolymer?
title_short How Accurate Is Oral Implant Installation Using Surgical Guides Printed from a Degradable and Steam-Sterilized Biopolymer?
title_sort how accurate is oral implant installation using surgical guides printed from a degradable and steam-sterilized biopolymer?
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7463912/
https://www.ncbi.nlm.nih.gov/pubmed/32707759
http://dx.doi.org/10.3390/jcm9082322
work_keys_str_mv AT pierallistefano howaccurateisoralimplantinstallationusingsurgicalguidesprintedfromadegradableandsteamsterilizedbiopolymer
AT spiesbenediktchristopher howaccurateisoralimplantinstallationusingsurgicalguidesprintedfromadegradableandsteamsterilizedbiopolymer
AT hromadnikvalentin howaccurateisoralimplantinstallationusingsurgicalguidesprintedfromadegradableandsteamsterilizedbiopolymer
AT nicicrobert howaccurateisoralimplantinstallationusingsurgicalguidesprintedfromadegradableandsteamsterilizedbiopolymer
AT beuerflorian howaccurateisoralimplantinstallationusingsurgicalguidesprintedfromadegradableandsteamsterilizedbiopolymer
AT wesemannchristian howaccurateisoralimplantinstallationusingsurgicalguidesprintedfromadegradableandsteamsterilizedbiopolymer