Cargando…
Cyclic fatigue resistance of reduced-taper nickel-titanium (NiTi) instruments in doubled-curved (S-shaped) canals at body temperature
Background. This study was conducted to compare the cyclic fatigue resistance of VDW.ROTATE, TruNatomy Prime, HyFlex CM, and 2Shape nickel-titanium (NiTi) rotary instruments in double-curved canals in a simulated clinical environment. Methods. Eighty NiTi files were used for the fatigue testing in s...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Tabriz University of Medical Sciences
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7464224/ https://www.ncbi.nlm.nih.gov/pubmed/32908652 http://dx.doi.org/10.34172/joddd.2020.024 |
_version_ | 1783577314885369856 |
---|---|
author | Uslu, Gülşah Gundogar, Mustafa Özyurek, Taha Plotino, Gianluca |
author_facet | Uslu, Gülşah Gundogar, Mustafa Özyurek, Taha Plotino, Gianluca |
author_sort | Uslu, Gülşah |
collection | PubMed |
description | Background. This study was conducted to compare the cyclic fatigue resistance of VDW.ROTATE, TruNatomy Prime, HyFlex CM, and 2Shape nickel-titanium (NiTi) rotary instruments in double-curved canals in a simulated clinical environment. Methods. Eighty NiTi files were used for the fatigue testing in stainless steel canals compatible with instrument sizes until fracture occurred (n=20): VDW.ROTATE (04./25#), TruNatomy Prime (04./26#), HyFlex CM (04./25#) and 2Shape TS04./25#( 1). For each instrument, the number of cycles to fracture (NCF) was calculated, and the fractured fragment length (FL) was measured. To verify that the files were fractured due to cyclic fatigue, the fractured surfaces of the files were evaluated under a scanning electron microscope. Data were statistically analyzed using the Kruskal–Wallis and Student’s t-tests at the %95 confidence level. Results. The failure of the files due to cyclic fatigue was first seen in the apical curvature before the coronal curvature (P<0.05). The highest fatigue resistance was observed in VDW.ROTATE and HyFlex CM files in both curvatures (P<0.05). There were no significant differences in the fatigue resistance between the HyFlex CM and VDW.ROTATE files or between the 2Shape and the TruNatomy files (P>0.05). There was no difference in the fractured lengths of the files between the apical and coronal curvatures (P>0.05). Conclusion. In artificial S-shaped root canals, VDW.ROTATE and HyFlex CM files exhibited higher fatigue resistance compared to 2Shape and TruNatomy files. |
format | Online Article Text |
id | pubmed-7464224 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Tabriz University of Medical Sciences |
record_format | MEDLINE/PubMed |
spelling | pubmed-74642242020-09-08 Cyclic fatigue resistance of reduced-taper nickel-titanium (NiTi) instruments in doubled-curved (S-shaped) canals at body temperature Uslu, Gülşah Gundogar, Mustafa Özyurek, Taha Plotino, Gianluca J Dent Res Dent Clin Dent Prospects Original Article Background. This study was conducted to compare the cyclic fatigue resistance of VDW.ROTATE, TruNatomy Prime, HyFlex CM, and 2Shape nickel-titanium (NiTi) rotary instruments in double-curved canals in a simulated clinical environment. Methods. Eighty NiTi files were used for the fatigue testing in stainless steel canals compatible with instrument sizes until fracture occurred (n=20): VDW.ROTATE (04./25#), TruNatomy Prime (04./26#), HyFlex CM (04./25#) and 2Shape TS04./25#( 1). For each instrument, the number of cycles to fracture (NCF) was calculated, and the fractured fragment length (FL) was measured. To verify that the files were fractured due to cyclic fatigue, the fractured surfaces of the files were evaluated under a scanning electron microscope. Data were statistically analyzed using the Kruskal–Wallis and Student’s t-tests at the %95 confidence level. Results. The failure of the files due to cyclic fatigue was first seen in the apical curvature before the coronal curvature (P<0.05). The highest fatigue resistance was observed in VDW.ROTATE and HyFlex CM files in both curvatures (P<0.05). There were no significant differences in the fatigue resistance between the HyFlex CM and VDW.ROTATE files or between the 2Shape and the TruNatomy files (P>0.05). There was no difference in the fractured lengths of the files between the apical and coronal curvatures (P>0.05). Conclusion. In artificial S-shaped root canals, VDW.ROTATE and HyFlex CM files exhibited higher fatigue resistance compared to 2Shape and TruNatomy files. Tabriz University of Medical Sciences 2020 2020-06-17 /pmc/articles/PMC7464224/ /pubmed/32908652 http://dx.doi.org/10.34172/joddd.2020.024 Text en © 2020 The Authors. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Uslu, Gülşah Gundogar, Mustafa Özyurek, Taha Plotino, Gianluca Cyclic fatigue resistance of reduced-taper nickel-titanium (NiTi) instruments in doubled-curved (S-shaped) canals at body temperature |
title | Cyclic fatigue resistance of reduced-taper nickel-titanium (NiTi) instruments in doubled-curved (S-shaped) canals at body temperature |
title_full | Cyclic fatigue resistance of reduced-taper nickel-titanium (NiTi) instruments in doubled-curved (S-shaped) canals at body temperature |
title_fullStr | Cyclic fatigue resistance of reduced-taper nickel-titanium (NiTi) instruments in doubled-curved (S-shaped) canals at body temperature |
title_full_unstemmed | Cyclic fatigue resistance of reduced-taper nickel-titanium (NiTi) instruments in doubled-curved (S-shaped) canals at body temperature |
title_short | Cyclic fatigue resistance of reduced-taper nickel-titanium (NiTi) instruments in doubled-curved (S-shaped) canals at body temperature |
title_sort | cyclic fatigue resistance of reduced-taper nickel-titanium (niti) instruments in doubled-curved (s-shaped) canals at body temperature |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7464224/ https://www.ncbi.nlm.nih.gov/pubmed/32908652 http://dx.doi.org/10.34172/joddd.2020.024 |
work_keys_str_mv | AT uslugulsah cyclicfatigueresistanceofreducedtapernickeltitaniumnitiinstrumentsindoubledcurvedsshapedcanalsatbodytemperature AT gundogarmustafa cyclicfatigueresistanceofreducedtapernickeltitaniumnitiinstrumentsindoubledcurvedsshapedcanalsatbodytemperature AT ozyurektaha cyclicfatigueresistanceofreducedtapernickeltitaniumnitiinstrumentsindoubledcurvedsshapedcanalsatbodytemperature AT plotinogianluca cyclicfatigueresistanceofreducedtapernickeltitaniumnitiinstrumentsindoubledcurvedsshapedcanalsatbodytemperature |