Cargando…

Safe Coated Microneedles with Reduced Puncture Occurrence after Administration

The goal of this study is the preparation of safer coated microneedles so that tips remaining after the initial use are less likely to be reinserted on a second use. Twelve groups of uncoated microneedles (u-MNs) were prepared from the combination of three different aspect ratios (height to base wid...

Descripción completa

Detalles Bibliográficos
Autores principales: Jeong, Hye-Rin, Jun, Hyesun, Cha, Hye-Ran, Lee, Jae Myun, Park, Jung-Hwan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7464251/
https://www.ncbi.nlm.nih.gov/pubmed/32707873
http://dx.doi.org/10.3390/mi11080710
_version_ 1783577321505030144
author Jeong, Hye-Rin
Jun, Hyesun
Cha, Hye-Ran
Lee, Jae Myun
Park, Jung-Hwan
author_facet Jeong, Hye-Rin
Jun, Hyesun
Cha, Hye-Ran
Lee, Jae Myun
Park, Jung-Hwan
author_sort Jeong, Hye-Rin
collection PubMed
description The goal of this study is the preparation of safer coated microneedles so that tips remaining after the initial use are less likely to be reinserted on a second use. Twelve groups of uncoated microneedles (u-MNs) were prepared from the combination of three different aspect ratios (height to base width) and four kinds of polymer (polyethylene (PE), polypropylene (PP), nylon and polylactic acid (PLA)). After coating the u-MNs with polyvinyl alcohol formulation to make coated MNs (c-MNs), the force displacement of the u-MNs and the c-MNs was measured. The aspect ratio was reduced from 2.2, 2.5 and 3.0 with u-MNs to 1.3, 1.4 and 1.6 with c-MNs, respectively, after the coating formulation was applied to the MNs. All PLA MNs had a puncture performance of more than 95%. However, the puncture performance of u-MNs made of PE and of PP with a 3.0 aspect ratio was only 8% and 53%, respectively, whereas the rates of c-MNs made of PE and of PP were 82% and 95%, respectively. In animal experiments with PP MNs with a 3.0 aspect ratio, the 59% rate of puncture performance with u-MNs increased to above 96% with c-MNs and fell to 13% for r-MNs. Safe c-MNs can overcome the disadvantages of standard c-MNs by reducing the probable contamination of remaining tips after use. Safe c-MNs have advantages over standard c-MNs in terms of humidity resistance, reasonable cost, sterilization process and short processing time through the separate process of u-MN preparation and simple dip-coating.
format Online
Article
Text
id pubmed-7464251
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-74642512020-09-04 Safe Coated Microneedles with Reduced Puncture Occurrence after Administration Jeong, Hye-Rin Jun, Hyesun Cha, Hye-Ran Lee, Jae Myun Park, Jung-Hwan Micromachines (Basel) Article The goal of this study is the preparation of safer coated microneedles so that tips remaining after the initial use are less likely to be reinserted on a second use. Twelve groups of uncoated microneedles (u-MNs) were prepared from the combination of three different aspect ratios (height to base width) and four kinds of polymer (polyethylene (PE), polypropylene (PP), nylon and polylactic acid (PLA)). After coating the u-MNs with polyvinyl alcohol formulation to make coated MNs (c-MNs), the force displacement of the u-MNs and the c-MNs was measured. The aspect ratio was reduced from 2.2, 2.5 and 3.0 with u-MNs to 1.3, 1.4 and 1.6 with c-MNs, respectively, after the coating formulation was applied to the MNs. All PLA MNs had a puncture performance of more than 95%. However, the puncture performance of u-MNs made of PE and of PP with a 3.0 aspect ratio was only 8% and 53%, respectively, whereas the rates of c-MNs made of PE and of PP were 82% and 95%, respectively. In animal experiments with PP MNs with a 3.0 aspect ratio, the 59% rate of puncture performance with u-MNs increased to above 96% with c-MNs and fell to 13% for r-MNs. Safe c-MNs can overcome the disadvantages of standard c-MNs by reducing the probable contamination of remaining tips after use. Safe c-MNs have advantages over standard c-MNs in terms of humidity resistance, reasonable cost, sterilization process and short processing time through the separate process of u-MN preparation and simple dip-coating. MDPI 2020-07-22 /pmc/articles/PMC7464251/ /pubmed/32707873 http://dx.doi.org/10.3390/mi11080710 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Jeong, Hye-Rin
Jun, Hyesun
Cha, Hye-Ran
Lee, Jae Myun
Park, Jung-Hwan
Safe Coated Microneedles with Reduced Puncture Occurrence after Administration
title Safe Coated Microneedles with Reduced Puncture Occurrence after Administration
title_full Safe Coated Microneedles with Reduced Puncture Occurrence after Administration
title_fullStr Safe Coated Microneedles with Reduced Puncture Occurrence after Administration
title_full_unstemmed Safe Coated Microneedles with Reduced Puncture Occurrence after Administration
title_short Safe Coated Microneedles with Reduced Puncture Occurrence after Administration
title_sort safe coated microneedles with reduced puncture occurrence after administration
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7464251/
https://www.ncbi.nlm.nih.gov/pubmed/32707873
http://dx.doi.org/10.3390/mi11080710
work_keys_str_mv AT jeonghyerin safecoatedmicroneedleswithreducedpunctureoccurrenceafteradministration
AT junhyesun safecoatedmicroneedleswithreducedpunctureoccurrenceafteradministration
AT chahyeran safecoatedmicroneedleswithreducedpunctureoccurrenceafteradministration
AT leejaemyun safecoatedmicroneedleswithreducedpunctureoccurrenceafteradministration
AT parkjunghwan safecoatedmicroneedleswithreducedpunctureoccurrenceafteradministration