Vascular Stents Coated with Electrospun Drug-Eluting Material: Functioning in Rabbit Iliac Artery

A stenting procedure aimed at blood flow restoration in stenosed arteries significantly improves the efficiency of vascular surgery. However, the current challenge is to prevent neointimal growth, which reduces the vessel lumen, in the stented segments in the long run. We tested in vivo drug-eluting...

Descripción completa

Detalles Bibliográficos
Autores principales: Kuznetsov, Konstantin A., Murashov, Ivan S., Chernonosova, Vera S., Chelobanov, Boris P., Stepanova, Alena O., Sergeevichev, David S., Karpenko, Andrey A., Laktionov, Pavel P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7465440/
https://www.ncbi.nlm.nih.gov/pubmed/32759856
http://dx.doi.org/10.3390/polym12081741
_version_ 1783577588317290496
author Kuznetsov, Konstantin A.
Murashov, Ivan S.
Chernonosova, Vera S.
Chelobanov, Boris P.
Stepanova, Alena O.
Sergeevichev, David S.
Karpenko, Andrey A.
Laktionov, Pavel P.
author_facet Kuznetsov, Konstantin A.
Murashov, Ivan S.
Chernonosova, Vera S.
Chelobanov, Boris P.
Stepanova, Alena O.
Sergeevichev, David S.
Karpenko, Andrey A.
Laktionov, Pavel P.
author_sort Kuznetsov, Konstantin A.
collection PubMed
description A stenting procedure aimed at blood flow restoration in stenosed arteries significantly improves the efficiency of vascular surgery. However, the current challenge is to prevent neointimal growth, which reduces the vessel lumen, in the stented segments in the long run. We tested in vivo drug-eluting coating applied by electrospinning to metal vascular stents to inhibit the overgrowth of neointimal cells via both the drug release and mechanical support of the vascular wall. The blend of polycaprolactone with human serum albumin and paclitaxel was used for stent coating by electrospinning. The drug-eluting stents (DESs) were placed using a balloon catheter to the rabbit common iliac artery for 1, 3, and 6 months. The blood flow rate was ultrasonically determined in vivo. After explantation, the stented arterial segment was visually and histologically examined. Any undesirable biological responses (rejection or hemodynamically significant stenosis) were unobservable in the experimental groups. DESs were less traumatic and induced weaker neointimal growth; over six months, the blood flow increased by 37% versus bare-metal stents, where it increased by at least double the rate. Thus, electrospun-coated DESs demonstrate considerable advantages over the bare-metal variants.
format Online
Article
Text
id pubmed-7465440
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-74654402020-09-04 Vascular Stents Coated with Electrospun Drug-Eluting Material: Functioning in Rabbit Iliac Artery Kuznetsov, Konstantin A. Murashov, Ivan S. Chernonosova, Vera S. Chelobanov, Boris P. Stepanova, Alena O. Sergeevichev, David S. Karpenko, Andrey A. Laktionov, Pavel P. Polymers (Basel) Article A stenting procedure aimed at blood flow restoration in stenosed arteries significantly improves the efficiency of vascular surgery. However, the current challenge is to prevent neointimal growth, which reduces the vessel lumen, in the stented segments in the long run. We tested in vivo drug-eluting coating applied by electrospinning to metal vascular stents to inhibit the overgrowth of neointimal cells via both the drug release and mechanical support of the vascular wall. The blend of polycaprolactone with human serum albumin and paclitaxel was used for stent coating by electrospinning. The drug-eluting stents (DESs) were placed using a balloon catheter to the rabbit common iliac artery for 1, 3, and 6 months. The blood flow rate was ultrasonically determined in vivo. After explantation, the stented arterial segment was visually and histologically examined. Any undesirable biological responses (rejection or hemodynamically significant stenosis) were unobservable in the experimental groups. DESs were less traumatic and induced weaker neointimal growth; over six months, the blood flow increased by 37% versus bare-metal stents, where it increased by at least double the rate. Thus, electrospun-coated DESs demonstrate considerable advantages over the bare-metal variants. MDPI 2020-08-04 /pmc/articles/PMC7465440/ /pubmed/32759856 http://dx.doi.org/10.3390/polym12081741 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Kuznetsov, Konstantin A.
Murashov, Ivan S.
Chernonosova, Vera S.
Chelobanov, Boris P.
Stepanova, Alena O.
Sergeevichev, David S.
Karpenko, Andrey A.
Laktionov, Pavel P.
Vascular Stents Coated with Electrospun Drug-Eluting Material: Functioning in Rabbit Iliac Artery
title Vascular Stents Coated with Electrospun Drug-Eluting Material: Functioning in Rabbit Iliac Artery
title_full Vascular Stents Coated with Electrospun Drug-Eluting Material: Functioning in Rabbit Iliac Artery
title_fullStr Vascular Stents Coated with Electrospun Drug-Eluting Material: Functioning in Rabbit Iliac Artery
title_full_unstemmed Vascular Stents Coated with Electrospun Drug-Eluting Material: Functioning in Rabbit Iliac Artery
title_short Vascular Stents Coated with Electrospun Drug-Eluting Material: Functioning in Rabbit Iliac Artery
title_sort vascular stents coated with electrospun drug-eluting material: functioning in rabbit iliac artery
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7465440/
https://www.ncbi.nlm.nih.gov/pubmed/32759856
http://dx.doi.org/10.3390/polym12081741
work_keys_str_mv AT kuznetsovkonstantina vascularstentscoatedwithelectrospundrugelutingmaterialfunctioninginrabbitiliacartery
AT murashovivans vascularstentscoatedwithelectrospundrugelutingmaterialfunctioninginrabbitiliacartery
AT chernonosovaveras vascularstentscoatedwithelectrospundrugelutingmaterialfunctioninginrabbitiliacartery
AT chelobanovborisp vascularstentscoatedwithelectrospundrugelutingmaterialfunctioninginrabbitiliacartery
AT stepanovaalenao vascularstentscoatedwithelectrospundrugelutingmaterialfunctioninginrabbitiliacartery
AT sergeevichevdavids vascularstentscoatedwithelectrospundrugelutingmaterialfunctioninginrabbitiliacartery
AT karpenkoandreya vascularstentscoatedwithelectrospundrugelutingmaterialfunctioninginrabbitiliacartery
AT laktionovpavelp vascularstentscoatedwithelectrospundrugelutingmaterialfunctioninginrabbitiliacartery