Multichannel Electrocardiograms Obtained by a Smartwatch for the Diagnosis of ST-Segment Changes

IMPORTANCE: Acute coronary syndromes are the leading cause of death worldwide and the leading cause of disease burden in high-income countries. Quick and accurate diagnosis of acute coronary syndromes is essential to avoid fatal events, for timely intervention, and to improve the prognosis. OBJECTIV...

Descripción completa

Detalles Bibliográficos
Autores principales: Spaccarotella, Carmen Anna Maria, Polimeni, Alberto, Migliarino, Serena, Principe, Elisa, Curcio, Antonio, Mongiardo, Annalisa, Sorrentino, Sabato, De Rosa, Salvatore, Indolfi, Ciro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Medical Association 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7466842/
https://www.ncbi.nlm.nih.gov/pubmed/32865545
http://dx.doi.org/10.1001/jamacardio.2020.3994
_version_ 1783577902103658496
author Spaccarotella, Carmen Anna Maria
Polimeni, Alberto
Migliarino, Serena
Principe, Elisa
Curcio, Antonio
Mongiardo, Annalisa
Sorrentino, Sabato
De Rosa, Salvatore
Indolfi, Ciro
author_facet Spaccarotella, Carmen Anna Maria
Polimeni, Alberto
Migliarino, Serena
Principe, Elisa
Curcio, Antonio
Mongiardo, Annalisa
Sorrentino, Sabato
De Rosa, Salvatore
Indolfi, Ciro
author_sort Spaccarotella, Carmen Anna Maria
collection PubMed
description IMPORTANCE: Acute coronary syndromes are the leading cause of death worldwide and the leading cause of disease burden in high-income countries. Quick and accurate diagnosis of acute coronary syndromes is essential to avoid fatal events, for timely intervention, and to improve the prognosis. OBJECTIVE: To prospectively investigate the feasibility and accuracy of a smartwatch in recording multiple electrocardiographic (ECG) leads and detecting ST-segment changes associated with acute coronary syndromes compared with a standard 12-lead ECG. DESIGN, SETTING, AND PARTICIPANTS: A commercially available smartwatch was used in 100 participants to obtain multiple-channel ECGs. The study was conducted from April 19, 2019, to January 23, 2020. Fifty-four patients with ST elevation myocardial infarction, 27 patients with non-ST elevation myocardial infarction, and 19 healthy individuals were included in the study. The watch was placed in different body positions to obtain 9 bipolar ECG tracings (corresponding to Einthoven leads I, II, and III and precordial leads V1-V6) that were compared with a simultaneous standard 12-lead ECG. MAIN OUTCOMES AND MEASURES: The concordance among the results of the smartwatch and standard ECG recordings was assessed using the Cohen κ coefficient and Bland-Altman analysis. RESULTS: Of the 100 participants in the study, 67 were men (67%); mean (SD) age was 61 (16) years. Agreement was found between the smartwatch and standard ECG for the identification of a normal ECG (Cohen κ coefficient, 0.90; 95% CI, 0.78-1.00), ST-segment elevation changes (Cohen κ coefficient, 0.88; 95% CI, 0.78-0.97), and non–ST-segment elevation changes (Cohen κ coefficient, 0.85; 95% CI, 0.74-0.96). In addition, the Bland-Altman analysis demonstrated agreement between the smartwatch and standard ECG to detect the amplitude of ST-segment changes (bias, −0.003; SD, 0.18; lower limit, −0.36; and upper limit, 0.36). Use of the smartwatch ECG for the diagnosis of normal ECG showed a sensitivity of 84% (95% CI, 60%-97%) and specificity of 100% (95% CI, 95%-100%); for ST elevation, sensitivity was 93% (95% CI, 82%-99%) and specificity was 95% (95% CI, 85%-99%); and for NSTE ECG alterations, sensitivity was 94% (95% CI, 81%-99%) and specificity was 92% (95% CI, 83%-97%). CONCLUSIONS AND RELEVANCE: The findings of this study suggest agreement between the multichannel smartwatch ECG and standard ECG for the identification of ST-segment changes in patients with acute coronary syndromes.
format Online
Article
Text
id pubmed-7466842
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher American Medical Association
record_format MEDLINE/PubMed
spelling pubmed-74668422020-09-25 Multichannel Electrocardiograms Obtained by a Smartwatch for the Diagnosis of ST-Segment Changes Spaccarotella, Carmen Anna Maria Polimeni, Alberto Migliarino, Serena Principe, Elisa Curcio, Antonio Mongiardo, Annalisa Sorrentino, Sabato De Rosa, Salvatore Indolfi, Ciro JAMA Cardiol Brief Report IMPORTANCE: Acute coronary syndromes are the leading cause of death worldwide and the leading cause of disease burden in high-income countries. Quick and accurate diagnosis of acute coronary syndromes is essential to avoid fatal events, for timely intervention, and to improve the prognosis. OBJECTIVE: To prospectively investigate the feasibility and accuracy of a smartwatch in recording multiple electrocardiographic (ECG) leads and detecting ST-segment changes associated with acute coronary syndromes compared with a standard 12-lead ECG. DESIGN, SETTING, AND PARTICIPANTS: A commercially available smartwatch was used in 100 participants to obtain multiple-channel ECGs. The study was conducted from April 19, 2019, to January 23, 2020. Fifty-four patients with ST elevation myocardial infarction, 27 patients with non-ST elevation myocardial infarction, and 19 healthy individuals were included in the study. The watch was placed in different body positions to obtain 9 bipolar ECG tracings (corresponding to Einthoven leads I, II, and III and precordial leads V1-V6) that were compared with a simultaneous standard 12-lead ECG. MAIN OUTCOMES AND MEASURES: The concordance among the results of the smartwatch and standard ECG recordings was assessed using the Cohen κ coefficient and Bland-Altman analysis. RESULTS: Of the 100 participants in the study, 67 were men (67%); mean (SD) age was 61 (16) years. Agreement was found between the smartwatch and standard ECG for the identification of a normal ECG (Cohen κ coefficient, 0.90; 95% CI, 0.78-1.00), ST-segment elevation changes (Cohen κ coefficient, 0.88; 95% CI, 0.78-0.97), and non–ST-segment elevation changes (Cohen κ coefficient, 0.85; 95% CI, 0.74-0.96). In addition, the Bland-Altman analysis demonstrated agreement between the smartwatch and standard ECG to detect the amplitude of ST-segment changes (bias, −0.003; SD, 0.18; lower limit, −0.36; and upper limit, 0.36). Use of the smartwatch ECG for the diagnosis of normal ECG showed a sensitivity of 84% (95% CI, 60%-97%) and specificity of 100% (95% CI, 95%-100%); for ST elevation, sensitivity was 93% (95% CI, 82%-99%) and specificity was 95% (95% CI, 85%-99%); and for NSTE ECG alterations, sensitivity was 94% (95% CI, 81%-99%) and specificity was 92% (95% CI, 83%-97%). CONCLUSIONS AND RELEVANCE: The findings of this study suggest agreement between the multichannel smartwatch ECG and standard ECG for the identification of ST-segment changes in patients with acute coronary syndromes. American Medical Association 2020-10 2020-08-31 /pmc/articles/PMC7466842/ /pubmed/32865545 http://dx.doi.org/10.1001/jamacardio.2020.3994 Text en Copyright 2020 Spaccarotella CAM et al. JAMA Cardiology. http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the CC-BY License.
spellingShingle Brief Report
Spaccarotella, Carmen Anna Maria
Polimeni, Alberto
Migliarino, Serena
Principe, Elisa
Curcio, Antonio
Mongiardo, Annalisa
Sorrentino, Sabato
De Rosa, Salvatore
Indolfi, Ciro
Multichannel Electrocardiograms Obtained by a Smartwatch for the Diagnosis of ST-Segment Changes
title Multichannel Electrocardiograms Obtained by a Smartwatch for the Diagnosis of ST-Segment Changes
title_full Multichannel Electrocardiograms Obtained by a Smartwatch for the Diagnosis of ST-Segment Changes
title_fullStr Multichannel Electrocardiograms Obtained by a Smartwatch for the Diagnosis of ST-Segment Changes
title_full_unstemmed Multichannel Electrocardiograms Obtained by a Smartwatch for the Diagnosis of ST-Segment Changes
title_short Multichannel Electrocardiograms Obtained by a Smartwatch for the Diagnosis of ST-Segment Changes
title_sort multichannel electrocardiograms obtained by a smartwatch for the diagnosis of st-segment changes
topic Brief Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7466842/
https://www.ncbi.nlm.nih.gov/pubmed/32865545
http://dx.doi.org/10.1001/jamacardio.2020.3994
work_keys_str_mv AT spaccarotellacarmenannamaria multichannelelectrocardiogramsobtainedbyasmartwatchforthediagnosisofstsegmentchanges
AT polimenialberto multichannelelectrocardiogramsobtainedbyasmartwatchforthediagnosisofstsegmentchanges
AT migliarinoserena multichannelelectrocardiogramsobtainedbyasmartwatchforthediagnosisofstsegmentchanges
AT principeelisa multichannelelectrocardiogramsobtainedbyasmartwatchforthediagnosisofstsegmentchanges
AT curcioantonio multichannelelectrocardiogramsobtainedbyasmartwatchforthediagnosisofstsegmentchanges
AT mongiardoannalisa multichannelelectrocardiogramsobtainedbyasmartwatchforthediagnosisofstsegmentchanges
AT sorrentinosabato multichannelelectrocardiogramsobtainedbyasmartwatchforthediagnosisofstsegmentchanges
AT derosasalvatore multichannelelectrocardiogramsobtainedbyasmartwatchforthediagnosisofstsegmentchanges
AT indolficiro multichannelelectrocardiogramsobtainedbyasmartwatchforthediagnosisofstsegmentchanges