Cargando…

Effect of (Mis)Matched Compression Speed on Speech Recognition in Bimodal Listeners

Automatic gain control (AGC) compresses the wide dynamic range of sounds to the narrow dynamic range of hearing-impaired listeners. Setting AGC parameters (time constants and knee points) is an important part of the fitting of hearing devices. These parameters do not only influence overall loudness...

Descripción completa

Detalles Bibliográficos
Autores principales: Spirrov, Dimitar, Kludt, Eugen, Verschueren, Eline, Büchner, Andreas, Francart, Tom
Formato: Online Artículo Texto
Lenguaje:English
Publicado: SAGE Publications 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7466877/
https://www.ncbi.nlm.nih.gov/pubmed/32865486
http://dx.doi.org/10.1177/2331216520948974
_version_ 1783577908368900096
author Spirrov, Dimitar
Kludt, Eugen
Verschueren, Eline
Büchner, Andreas
Francart, Tom
author_facet Spirrov, Dimitar
Kludt, Eugen
Verschueren, Eline
Büchner, Andreas
Francart, Tom
author_sort Spirrov, Dimitar
collection PubMed
description Automatic gain control (AGC) compresses the wide dynamic range of sounds to the narrow dynamic range of hearing-impaired listeners. Setting AGC parameters (time constants and knee points) is an important part of the fitting of hearing devices. These parameters do not only influence overall loudness elicited by the hearing devices but can also affect the recognition of speech in noise. We investigated whether matching knee points and time constants of the AGC between the cochlear implant and the hearing aid of bimodal listeners would improve speech recognition in noise. We recruited 18 bimodal listeners and provided them all with the same cochlear-implant processor and hearing aid. We compared the matched AGCs with the default device settings with mismatched AGCs. As a baseline, we also included a condition with the mismatched AGCs of the participants’ own devices. We tested speech recognition in quiet and in noise presented from different directions. The time constants affected outcomes in the monaural testing condition with the cochlear implant alone. There were no specific binaural performance differences between the two AGC settings. Therefore, the performance was mostly dependent on the monaural cochlear implant alone condition.
format Online
Article
Text
id pubmed-7466877
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher SAGE Publications
record_format MEDLINE/PubMed
spelling pubmed-74668772020-09-16 Effect of (Mis)Matched Compression Speed on Speech Recognition in Bimodal Listeners Spirrov, Dimitar Kludt, Eugen Verschueren, Eline Büchner, Andreas Francart, Tom Trends Hear Original Article Automatic gain control (AGC) compresses the wide dynamic range of sounds to the narrow dynamic range of hearing-impaired listeners. Setting AGC parameters (time constants and knee points) is an important part of the fitting of hearing devices. These parameters do not only influence overall loudness elicited by the hearing devices but can also affect the recognition of speech in noise. We investigated whether matching knee points and time constants of the AGC between the cochlear implant and the hearing aid of bimodal listeners would improve speech recognition in noise. We recruited 18 bimodal listeners and provided them all with the same cochlear-implant processor and hearing aid. We compared the matched AGCs with the default device settings with mismatched AGCs. As a baseline, we also included a condition with the mismatched AGCs of the participants’ own devices. We tested speech recognition in quiet and in noise presented from different directions. The time constants affected outcomes in the monaural testing condition with the cochlear implant alone. There were no specific binaural performance differences between the two AGC settings. Therefore, the performance was mostly dependent on the monaural cochlear implant alone condition. SAGE Publications 2020-08-31 /pmc/articles/PMC7466877/ /pubmed/32865486 http://dx.doi.org/10.1177/2331216520948974 Text en © The Author(s) 2020 https://creativecommons.org/licenses/by-nc/4.0/ Creative Commons Non Commercial CC BY-NC: This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage).
spellingShingle Original Article
Spirrov, Dimitar
Kludt, Eugen
Verschueren, Eline
Büchner, Andreas
Francart, Tom
Effect of (Mis)Matched Compression Speed on Speech Recognition in Bimodal Listeners
title Effect of (Mis)Matched Compression Speed on Speech Recognition in Bimodal Listeners
title_full Effect of (Mis)Matched Compression Speed on Speech Recognition in Bimodal Listeners
title_fullStr Effect of (Mis)Matched Compression Speed on Speech Recognition in Bimodal Listeners
title_full_unstemmed Effect of (Mis)Matched Compression Speed on Speech Recognition in Bimodal Listeners
title_short Effect of (Mis)Matched Compression Speed on Speech Recognition in Bimodal Listeners
title_sort effect of (mis)matched compression speed on speech recognition in bimodal listeners
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7466877/
https://www.ncbi.nlm.nih.gov/pubmed/32865486
http://dx.doi.org/10.1177/2331216520948974
work_keys_str_mv AT spirrovdimitar effectofmismatchedcompressionspeedonspeechrecognitioninbimodallisteners
AT kludteugen effectofmismatchedcompressionspeedonspeechrecognitioninbimodallisteners
AT verschuereneline effectofmismatchedcompressionspeedonspeechrecognitioninbimodallisteners
AT buchnerandreas effectofmismatchedcompressionspeedonspeechrecognitioninbimodallisteners
AT francarttom effectofmismatchedcompressionspeedonspeechrecognitioninbimodallisteners