Cargando…

Impaired bone quality characterized by apatite orientation under stress shielding following fixing of a fracture of the radius with a 3D printed Ti-6Al-4V custom-made bone plate in dogs

Custom-made implants have recently gained attention in veterinary medicine because of their ability to properly fit animal bones having a wide variety of shapes and sizes. The effect of custom-made implants on bone soundness and the regeneration process is not yet clear. We fabricated a 3D printed T...

Descripción completa

Detalles Bibliográficos
Autores principales: Mie, Keiichiro, Ishimoto, Takuya, Okamoto, Mari, Iimori, Yasumasa, Ashida, Kazuna, Yoshizaki, Karin, Nishida, Hidetaka, Nakano, Takayoshi, Akiyoshi, Hideo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7467283/
https://www.ncbi.nlm.nih.gov/pubmed/32877422
http://dx.doi.org/10.1371/journal.pone.0237678
_version_ 1783577979233763328
author Mie, Keiichiro
Ishimoto, Takuya
Okamoto, Mari
Iimori, Yasumasa
Ashida, Kazuna
Yoshizaki, Karin
Nishida, Hidetaka
Nakano, Takayoshi
Akiyoshi, Hideo
author_facet Mie, Keiichiro
Ishimoto, Takuya
Okamoto, Mari
Iimori, Yasumasa
Ashida, Kazuna
Yoshizaki, Karin
Nishida, Hidetaka
Nakano, Takayoshi
Akiyoshi, Hideo
author_sort Mie, Keiichiro
collection PubMed
description Custom-made implants have recently gained attention in veterinary medicine because of their ability to properly fit animal bones having a wide variety of shapes and sizes. The effect of custom-made implants on bone soundness and the regeneration process is not yet clear. We fabricated a 3D printed Ti-6Al-4V custom-made bone plate that fits the shape of the dog radius, and placed it into the radius where an osteotomy had been made. The preferential orientation of the apatite c-axis contributes to the mechanical integrity of the bone and is a reliable measure of bone quality. We determined this parameter as well as the bone shape and bone mineral density (BMD). The bone portion which lies parallel to the bone plate exhibited bone resorption, decreased BMD, and significant degradation of apatite orientation, relative to the portion outside the plate, at 7 months after the operation. This demonstrates the presence of stress shielding in which applied stress is not transmitted to bone due to the insertion of a stiff bone plate. This reduced stress condition clearly influences the bone regeneration process. The apatite orientation in the regenerated site remained different even after 7 months of regeneration, indicating insufficient mechanical function in the regenerated portion. This is the first study in which the apatite orientation and BMD of the radius were evaluated under conditions of stress shielding in dogs. Our results suggest that assessment of bone repair by radiography can indicate the degree of restoration of BMD, but not the apatite orientation.
format Online
Article
Text
id pubmed-7467283
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-74672832020-09-11 Impaired bone quality characterized by apatite orientation under stress shielding following fixing of a fracture of the radius with a 3D printed Ti-6Al-4V custom-made bone plate in dogs Mie, Keiichiro Ishimoto, Takuya Okamoto, Mari Iimori, Yasumasa Ashida, Kazuna Yoshizaki, Karin Nishida, Hidetaka Nakano, Takayoshi Akiyoshi, Hideo PLoS One Research Article Custom-made implants have recently gained attention in veterinary medicine because of their ability to properly fit animal bones having a wide variety of shapes and sizes. The effect of custom-made implants on bone soundness and the regeneration process is not yet clear. We fabricated a 3D printed Ti-6Al-4V custom-made bone plate that fits the shape of the dog radius, and placed it into the radius where an osteotomy had been made. The preferential orientation of the apatite c-axis contributes to the mechanical integrity of the bone and is a reliable measure of bone quality. We determined this parameter as well as the bone shape and bone mineral density (BMD). The bone portion which lies parallel to the bone plate exhibited bone resorption, decreased BMD, and significant degradation of apatite orientation, relative to the portion outside the plate, at 7 months after the operation. This demonstrates the presence of stress shielding in which applied stress is not transmitted to bone due to the insertion of a stiff bone plate. This reduced stress condition clearly influences the bone regeneration process. The apatite orientation in the regenerated site remained different even after 7 months of regeneration, indicating insufficient mechanical function in the regenerated portion. This is the first study in which the apatite orientation and BMD of the radius were evaluated under conditions of stress shielding in dogs. Our results suggest that assessment of bone repair by radiography can indicate the degree of restoration of BMD, but not the apatite orientation. Public Library of Science 2020-09-02 /pmc/articles/PMC7467283/ /pubmed/32877422 http://dx.doi.org/10.1371/journal.pone.0237678 Text en © 2020 Mie et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Mie, Keiichiro
Ishimoto, Takuya
Okamoto, Mari
Iimori, Yasumasa
Ashida, Kazuna
Yoshizaki, Karin
Nishida, Hidetaka
Nakano, Takayoshi
Akiyoshi, Hideo
Impaired bone quality characterized by apatite orientation under stress shielding following fixing of a fracture of the radius with a 3D printed Ti-6Al-4V custom-made bone plate in dogs
title Impaired bone quality characterized by apatite orientation under stress shielding following fixing of a fracture of the radius with a 3D printed Ti-6Al-4V custom-made bone plate in dogs
title_full Impaired bone quality characterized by apatite orientation under stress shielding following fixing of a fracture of the radius with a 3D printed Ti-6Al-4V custom-made bone plate in dogs
title_fullStr Impaired bone quality characterized by apatite orientation under stress shielding following fixing of a fracture of the radius with a 3D printed Ti-6Al-4V custom-made bone plate in dogs
title_full_unstemmed Impaired bone quality characterized by apatite orientation under stress shielding following fixing of a fracture of the radius with a 3D printed Ti-6Al-4V custom-made bone plate in dogs
title_short Impaired bone quality characterized by apatite orientation under stress shielding following fixing of a fracture of the radius with a 3D printed Ti-6Al-4V custom-made bone plate in dogs
title_sort impaired bone quality characterized by apatite orientation under stress shielding following fixing of a fracture of the radius with a 3d printed ti-6al-4v custom-made bone plate in dogs
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7467283/
https://www.ncbi.nlm.nih.gov/pubmed/32877422
http://dx.doi.org/10.1371/journal.pone.0237678
work_keys_str_mv AT miekeiichiro impairedbonequalitycharacterizedbyapatiteorientationunderstressshieldingfollowingfixingofafractureoftheradiuswitha3dprintedti6al4vcustommadeboneplateindogs
AT ishimototakuya impairedbonequalitycharacterizedbyapatiteorientationunderstressshieldingfollowingfixingofafractureoftheradiuswitha3dprintedti6al4vcustommadeboneplateindogs
AT okamotomari impairedbonequalitycharacterizedbyapatiteorientationunderstressshieldingfollowingfixingofafractureoftheradiuswitha3dprintedti6al4vcustommadeboneplateindogs
AT iimoriyasumasa impairedbonequalitycharacterizedbyapatiteorientationunderstressshieldingfollowingfixingofafractureoftheradiuswitha3dprintedti6al4vcustommadeboneplateindogs
AT ashidakazuna impairedbonequalitycharacterizedbyapatiteorientationunderstressshieldingfollowingfixingofafractureoftheradiuswitha3dprintedti6al4vcustommadeboneplateindogs
AT yoshizakikarin impairedbonequalitycharacterizedbyapatiteorientationunderstressshieldingfollowingfixingofafractureoftheradiuswitha3dprintedti6al4vcustommadeboneplateindogs
AT nishidahidetaka impairedbonequalitycharacterizedbyapatiteorientationunderstressshieldingfollowingfixingofafractureoftheradiuswitha3dprintedti6al4vcustommadeboneplateindogs
AT nakanotakayoshi impairedbonequalitycharacterizedbyapatiteorientationunderstressshieldingfollowingfixingofafractureoftheradiuswitha3dprintedti6al4vcustommadeboneplateindogs
AT akiyoshihideo impairedbonequalitycharacterizedbyapatiteorientationunderstressshieldingfollowingfixingofafractureoftheradiuswitha3dprintedti6al4vcustommadeboneplateindogs