Big Bag IOL Implantation with Scleral Fixation Technique in IOL/Crystalline Lens Subluxation/Luxation Cases and High Myopia

PURPOSE: The aim of this study is to report our experience in the surgical management of over 180° luxation/subluxation of the intraocular lens (IOL). Special cases are high myopic eyes, whose tissues are constitutionally more fragile, and consequently, surgery is more dangerous. PATIENTS AND METHOD...

Descripción completa

Detalles Bibliográficos
Autores principales: Nuzzi, Raffaele, Monteu, Francesca
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7467733/
https://www.ncbi.nlm.nih.gov/pubmed/32943945
http://dx.doi.org/10.2147/IMCRJ.S267180
_version_ 1783578077114138624
author Nuzzi, Raffaele
Monteu, Francesca
author_facet Nuzzi, Raffaele
Monteu, Francesca
author_sort Nuzzi, Raffaele
collection PubMed
description PURPOSE: The aim of this study is to report our experience in the surgical management of over 180° luxation/subluxation of the intraocular lens (IOL). Special cases are high myopic eyes, whose tissues are constitutionally more fragile, and consequently, surgery is more dangerous. PATIENTS AND METHODS: The authors propose the use of the Big Bag, three loops, IOL (Zeiss), to be implanted with the scleral fixation technique, with a double-armed needle. This technique seems to improve IOL stability and visual outcome of these patients. RESULTS: Big Bag IOL implantation with the scleral fixation technique in eyes with subluxation (over 180°) of the cataractous lens, high myopia and subluxation/dislocation of the IOL seems to suggest a possible and optimal management, with good long-term results and it is well tolerated by the patient. CONCLUSION: This specific ocular surgical technique can be used/standardized in all surgical “converted” complicated cases and especially in high myopic eyes.
format Online
Article
Text
id pubmed-7467733
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Dove
record_format MEDLINE/PubMed
spelling pubmed-74677332020-09-16 Big Bag IOL Implantation with Scleral Fixation Technique in IOL/Crystalline Lens Subluxation/Luxation Cases and High Myopia Nuzzi, Raffaele Monteu, Francesca Int Med Case Rep J Case Report PURPOSE: The aim of this study is to report our experience in the surgical management of over 180° luxation/subluxation of the intraocular lens (IOL). Special cases are high myopic eyes, whose tissues are constitutionally more fragile, and consequently, surgery is more dangerous. PATIENTS AND METHODS: The authors propose the use of the Big Bag, three loops, IOL (Zeiss), to be implanted with the scleral fixation technique, with a double-armed needle. This technique seems to improve IOL stability and visual outcome of these patients. RESULTS: Big Bag IOL implantation with the scleral fixation technique in eyes with subluxation (over 180°) of the cataractous lens, high myopia and subluxation/dislocation of the IOL seems to suggest a possible and optimal management, with good long-term results and it is well tolerated by the patient. CONCLUSION: This specific ocular surgical technique can be used/standardized in all surgical “converted” complicated cases and especially in high myopic eyes. Dove 2020-08-26 /pmc/articles/PMC7467733/ /pubmed/32943945 http://dx.doi.org/10.2147/IMCRJ.S267180 Text en © 2020 Nuzzi and Monteu. http://creativecommons.org/licenses/by-nc/3.0/ This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
spellingShingle Case Report
Nuzzi, Raffaele
Monteu, Francesca
Big Bag IOL Implantation with Scleral Fixation Technique in IOL/Crystalline Lens Subluxation/Luxation Cases and High Myopia
title Big Bag IOL Implantation with Scleral Fixation Technique in IOL/Crystalline Lens Subluxation/Luxation Cases and High Myopia
title_full Big Bag IOL Implantation with Scleral Fixation Technique in IOL/Crystalline Lens Subluxation/Luxation Cases and High Myopia
title_fullStr Big Bag IOL Implantation with Scleral Fixation Technique in IOL/Crystalline Lens Subluxation/Luxation Cases and High Myopia
title_full_unstemmed Big Bag IOL Implantation with Scleral Fixation Technique in IOL/Crystalline Lens Subluxation/Luxation Cases and High Myopia
title_short Big Bag IOL Implantation with Scleral Fixation Technique in IOL/Crystalline Lens Subluxation/Luxation Cases and High Myopia
title_sort big bag iol implantation with scleral fixation technique in iol/crystalline lens subluxation/luxation cases and high myopia
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7467733/
https://www.ncbi.nlm.nih.gov/pubmed/32943945
http://dx.doi.org/10.2147/IMCRJ.S267180
work_keys_str_mv AT nuzziraffaele bigbagiolimplantationwithscleralfixationtechniqueiniolcrystallinelenssubluxationluxationcasesandhighmyopia
AT monteufrancesca bigbagiolimplantationwithscleralfixationtechniqueiniolcrystallinelenssubluxationluxationcasesandhighmyopia