Comparative Evaluation of In-House and Commercial Real-Time PCR Methods for the Detection of the BK and JC Viruses in Clinical Samples

Aim  The two most common human polyomaviruses are the BK (BKV) and JC viruses (JCV). Diseases associated with polyomavirus usually occur in cases of severe cellular immunosuppression. BKV and JCV can cause many diseases, especially if they are reactivated in an immunosuppressed host. The aim of this...

Descripción completa

Detalles Bibliográficos
Autores principales: Özdemir, Mehmet, Ayan, Uğur, Şevik, Murat
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Thieme Medical and Scientific Publishers Private Ltd. 2020
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7467832/
https://www.ncbi.nlm.nih.gov/pubmed/32905317
http://dx.doi.org/10.1055/s-0040-1716603
_version_ 1783578093639696384
author Özdemir, Mehmet
Ayan, Uğur
Şevik, Murat
author_facet Özdemir, Mehmet
Ayan, Uğur
Şevik, Murat
author_sort Özdemir, Mehmet
collection PubMed
description Aim  The two most common human polyomaviruses are the BK (BKV) and JC viruses (JCV). Diseases associated with polyomavirus usually occur in cases of severe cellular immunosuppression. BKV and JCV can cause many diseases, especially if they are reactivated in an immunosuppressed host. The aim of this study is to compare and evaluate the results of real-time polymerase chain reaction (PCR) methods targeting the small and large T gene regions of the viral genome, considering polymorphisms occurring in the viral genome of BKV and JCV. Materials and Methods  Urinary specimens of 82 patients were taken from immunosuppressed patient and sent to molecular microbiology laboratory of Meram Medical Faculty. The small t gene was investigated using a commercial kit (LightMix, Roche) by real-time PCR method. Large T gene was investigated by using the optimized in-house real-time PCR method. Sequence analysis was accepted as the standard method. Results  BKV positivity was detected in 9 samples and JCV positivity in 61 samples by real-time PCR method specific to small t gene region; BKV positivity in 21 samples and JCV positivity in 67 samples were determined by real-time PCR method specific to the large T gene region. Statistically, there was a significant difference for BKV, but not significant difference for JCV detection between the two methods. Conclusion  Different polymorphisms in the target gene regions were responsible for the different outcomes obtained from this study. With this sensitivity and specificity, in-house PCR method which we used is a candidate for routine diagnosis.
format Online
Article
Text
id pubmed-7467832
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Thieme Medical and Scientific Publishers Private Ltd.
record_format MEDLINE/PubMed
spelling pubmed-74678322020-09-03 Comparative Evaluation of In-House and Commercial Real-Time PCR Methods for the Detection of the BK and JC Viruses in Clinical Samples Özdemir, Mehmet Ayan, Uğur Şevik, Murat J Lab Physicians Aim  The two most common human polyomaviruses are the BK (BKV) and JC viruses (JCV). Diseases associated with polyomavirus usually occur in cases of severe cellular immunosuppression. BKV and JCV can cause many diseases, especially if they are reactivated in an immunosuppressed host. The aim of this study is to compare and evaluate the results of real-time polymerase chain reaction (PCR) methods targeting the small and large T gene regions of the viral genome, considering polymorphisms occurring in the viral genome of BKV and JCV. Materials and Methods  Urinary specimens of 82 patients were taken from immunosuppressed patient and sent to molecular microbiology laboratory of Meram Medical Faculty. The small t gene was investigated using a commercial kit (LightMix, Roche) by real-time PCR method. Large T gene was investigated by using the optimized in-house real-time PCR method. Sequence analysis was accepted as the standard method. Results  BKV positivity was detected in 9 samples and JCV positivity in 61 samples by real-time PCR method specific to small t gene region; BKV positivity in 21 samples and JCV positivity in 67 samples were determined by real-time PCR method specific to the large T gene region. Statistically, there was a significant difference for BKV, but not significant difference for JCV detection between the two methods. Conclusion  Different polymorphisms in the target gene regions were responsible for the different outcomes obtained from this study. With this sensitivity and specificity, in-house PCR method which we used is a candidate for routine diagnosis. Thieme Medical and Scientific Publishers Private Ltd. 2020-08 2020-09-02 /pmc/articles/PMC7467832/ /pubmed/32905317 http://dx.doi.org/10.1055/s-0040-1716603 Text en https://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivatives License, which permits unrestricted reproduction and distribution, for non-commercial purposes only; and use and reproduction, but not distribution, of adapted material for non-commercial purposes only, provided the original work is properly cited.
spellingShingle Özdemir, Mehmet
Ayan, Uğur
Şevik, Murat
Comparative Evaluation of In-House and Commercial Real-Time PCR Methods for the Detection of the BK and JC Viruses in Clinical Samples
title Comparative Evaluation of In-House and Commercial Real-Time PCR Methods for the Detection of the BK and JC Viruses in Clinical Samples
title_full Comparative Evaluation of In-House and Commercial Real-Time PCR Methods for the Detection of the BK and JC Viruses in Clinical Samples
title_fullStr Comparative Evaluation of In-House and Commercial Real-Time PCR Methods for the Detection of the BK and JC Viruses in Clinical Samples
title_full_unstemmed Comparative Evaluation of In-House and Commercial Real-Time PCR Methods for the Detection of the BK and JC Viruses in Clinical Samples
title_short Comparative Evaluation of In-House and Commercial Real-Time PCR Methods for the Detection of the BK and JC Viruses in Clinical Samples
title_sort comparative evaluation of in-house and commercial real-time pcr methods for the detection of the bk and jc viruses in clinical samples
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7467832/
https://www.ncbi.nlm.nih.gov/pubmed/32905317
http://dx.doi.org/10.1055/s-0040-1716603
work_keys_str_mv AT ozdemirmehmet comparativeevaluationofinhouseandcommercialrealtimepcrmethodsforthedetectionofthebkandjcvirusesinclinicalsamples
AT ayanugur comparativeevaluationofinhouseandcommercialrealtimepcrmethodsforthedetectionofthebkandjcvirusesinclinicalsamples
AT sevikmurat comparativeevaluationofinhouseandcommercialrealtimepcrmethodsforthedetectionofthebkandjcvirusesinclinicalsamples