Cargando…

Cement augmentation of calcar screws may provide the greatest reduction in predicted screw cut-out risk for proximal humerus plating based on validated parametric computational modelling: Augmenting proximal humerus fracture plating

AIMS: Fixation of osteoporotic proximal humerus fractures remains challenging even with state-of-the-art locking plates. Despite the demonstrated biomechanical benefit of screw tip augmentation with bone cement, the clinical findings have remained unclear, potentially as the optimal augmentation com...

Descripción completa

Detalles Bibliográficos
Autores principales: Varga, Peter, Inzana, Jason A., Fletcher, James W. A., Hofmann-Fliri, Ladina, Runer, Armin, Südkamp, Norbert P., Windolf, Markus
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The British Editorial Society of Bone & Joint Surgery 2020
Materias:
Hip
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7469511/
https://www.ncbi.nlm.nih.gov/pubmed/32922762
http://dx.doi.org/10.1302/2046-3758.99.BJR-2020-0053.R1
_version_ 1783578432536313856
author Varga, Peter
Inzana, Jason A.
Fletcher, James W. A.
Hofmann-Fliri, Ladina
Runer, Armin
Südkamp, Norbert P.
Windolf, Markus
author_facet Varga, Peter
Inzana, Jason A.
Fletcher, James W. A.
Hofmann-Fliri, Ladina
Runer, Armin
Südkamp, Norbert P.
Windolf, Markus
author_sort Varga, Peter
collection PubMed
description AIMS: Fixation of osteoporotic proximal humerus fractures remains challenging even with state-of-the-art locking plates. Despite the demonstrated biomechanical benefit of screw tip augmentation with bone cement, the clinical findings have remained unclear, potentially as the optimal augmentation combinations are unknown. The aim of this study was to systematically evaluate the biomechanical benefits of the augmentation options in a humeral locking plate using finite element analysis (FEA). METHODS: A total of 64 cement augmentation configurations were analyzed using six screws of a locking plate to virtually fix unstable three-part fractures in 24 low-density proximal humerus models under three physiological loading cases (4,608 simulations). The biomechanical benefit of augmentation was evaluated through an established FEA methodology using the average peri-screw bone strain as a validated predictor of cyclic cut-out failure. RESULTS: The biomechanical benefit was already significant with a single cemented screw and increased with the number of augmented screws, but the configuration was highly influential. The best two-screw (mean 23%, SD 3% reduction) and the worst four-screw (mean 22%, SD 5%) combinations performed similarly. The largest benefits were achieved with augmenting screws purchasing into the calcar and having posteriorly located tips. Local bone mineral density was not directly related to the improvement. CONCLUSION: The number and configuration of cemented screws strongly determined how augmentation can alleviate the predicted risk of cut-out failure. Screws purchasing in the calcar and posterior humeral head regions may be prioritized. Although requiring clinical corroborations, these findings may explain the controversial results of previous clinical studies not controlling the choices of screw augmentation.
format Online
Article
Text
id pubmed-7469511
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher The British Editorial Society of Bone & Joint Surgery
record_format MEDLINE/PubMed
spelling pubmed-74695112020-09-10 Cement augmentation of calcar screws may provide the greatest reduction in predicted screw cut-out risk for proximal humerus plating based on validated parametric computational modelling: Augmenting proximal humerus fracture plating Varga, Peter Inzana, Jason A. Fletcher, James W. A. Hofmann-Fliri, Ladina Runer, Armin Südkamp, Norbert P. Windolf, Markus Bone Joint Res Hip AIMS: Fixation of osteoporotic proximal humerus fractures remains challenging even with state-of-the-art locking plates. Despite the demonstrated biomechanical benefit of screw tip augmentation with bone cement, the clinical findings have remained unclear, potentially as the optimal augmentation combinations are unknown. The aim of this study was to systematically evaluate the biomechanical benefits of the augmentation options in a humeral locking plate using finite element analysis (FEA). METHODS: A total of 64 cement augmentation configurations were analyzed using six screws of a locking plate to virtually fix unstable three-part fractures in 24 low-density proximal humerus models under three physiological loading cases (4,608 simulations). The biomechanical benefit of augmentation was evaluated through an established FEA methodology using the average peri-screw bone strain as a validated predictor of cyclic cut-out failure. RESULTS: The biomechanical benefit was already significant with a single cemented screw and increased with the number of augmented screws, but the configuration was highly influential. The best two-screw (mean 23%, SD 3% reduction) and the worst four-screw (mean 22%, SD 5%) combinations performed similarly. The largest benefits were achieved with augmenting screws purchasing into the calcar and having posteriorly located tips. Local bone mineral density was not directly related to the improvement. CONCLUSION: The number and configuration of cemented screws strongly determined how augmentation can alleviate the predicted risk of cut-out failure. Screws purchasing in the calcar and posterior humeral head regions may be prioritized. Although requiring clinical corroborations, these findings may explain the controversial results of previous clinical studies not controlling the choices of screw augmentation. The British Editorial Society of Bone & Joint Surgery 2020-09-03 /pmc/articles/PMC7469511/ /pubmed/32922762 http://dx.doi.org/10.1302/2046-3758.99.BJR-2020-0053.R1 Text en © 2020 Author(s) et al. https://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivatives (CC BY-NC-ND 4.0) licence, which permits the copying and redistribution of the work only, and provided the original author and source are credited.
spellingShingle Hip
Varga, Peter
Inzana, Jason A.
Fletcher, James W. A.
Hofmann-Fliri, Ladina
Runer, Armin
Südkamp, Norbert P.
Windolf, Markus
Cement augmentation of calcar screws may provide the greatest reduction in predicted screw cut-out risk for proximal humerus plating based on validated parametric computational modelling: Augmenting proximal humerus fracture plating
title Cement augmentation of calcar screws may provide the greatest reduction in predicted screw cut-out risk for proximal humerus plating based on validated parametric computational modelling: Augmenting proximal humerus fracture plating
title_full Cement augmentation of calcar screws may provide the greatest reduction in predicted screw cut-out risk for proximal humerus plating based on validated parametric computational modelling: Augmenting proximal humerus fracture plating
title_fullStr Cement augmentation of calcar screws may provide the greatest reduction in predicted screw cut-out risk for proximal humerus plating based on validated parametric computational modelling: Augmenting proximal humerus fracture plating
title_full_unstemmed Cement augmentation of calcar screws may provide the greatest reduction in predicted screw cut-out risk for proximal humerus plating based on validated parametric computational modelling: Augmenting proximal humerus fracture plating
title_short Cement augmentation of calcar screws may provide the greatest reduction in predicted screw cut-out risk for proximal humerus plating based on validated parametric computational modelling: Augmenting proximal humerus fracture plating
title_sort cement augmentation of calcar screws may provide the greatest reduction in predicted screw cut-out risk for proximal humerus plating based on validated parametric computational modelling: augmenting proximal humerus fracture plating
topic Hip
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7469511/
https://www.ncbi.nlm.nih.gov/pubmed/32922762
http://dx.doi.org/10.1302/2046-3758.99.BJR-2020-0053.R1
work_keys_str_mv AT vargapeter cementaugmentationofcalcarscrewsmayprovidethegreatestreductioninpredictedscrewcutoutriskforproximalhumerusplatingbasedonvalidatedparametriccomputationalmodellingaugmentingproximalhumerusfractureplating
AT inzanajasona cementaugmentationofcalcarscrewsmayprovidethegreatestreductioninpredictedscrewcutoutriskforproximalhumerusplatingbasedonvalidatedparametriccomputationalmodellingaugmentingproximalhumerusfractureplating
AT fletcherjameswa cementaugmentationofcalcarscrewsmayprovidethegreatestreductioninpredictedscrewcutoutriskforproximalhumerusplatingbasedonvalidatedparametriccomputationalmodellingaugmentingproximalhumerusfractureplating
AT hofmannfliriladina cementaugmentationofcalcarscrewsmayprovidethegreatestreductioninpredictedscrewcutoutriskforproximalhumerusplatingbasedonvalidatedparametriccomputationalmodellingaugmentingproximalhumerusfractureplating
AT runerarmin cementaugmentationofcalcarscrewsmayprovidethegreatestreductioninpredictedscrewcutoutriskforproximalhumerusplatingbasedonvalidatedparametriccomputationalmodellingaugmentingproximalhumerusfractureplating
AT sudkampnorbertp cementaugmentationofcalcarscrewsmayprovidethegreatestreductioninpredictedscrewcutoutriskforproximalhumerusplatingbasedonvalidatedparametriccomputationalmodellingaugmentingproximalhumerusfractureplating
AT windolfmarkus cementaugmentationofcalcarscrewsmayprovidethegreatestreductioninpredictedscrewcutoutriskforproximalhumerusplatingbasedonvalidatedparametriccomputationalmodellingaugmentingproximalhumerusfractureplating