Three‐dimensional printed navigational template for localizing small pulmonary nodules: A case‐controlled study

BACKGROUND: Localization of small pulmonary nodules is an inevitable challenge for the thoracic surgeon. This study aimed to investigate the accuracy of three‐dimensional (3D) printing technology for localizing small pulmonary nodules, especially ground‐glass nodules (GGNs). METHODS: This study enro...

Descripción completa

Detalles Bibliográficos
Autores principales: Fu, Rui, Chai, Yun‐Fei, Zhang, Jia‐Tao, Zhang, Tao, Chen, Xiao‐Kun, Dong, Song, Yan, Hong‐Hong, Yang, Xue‐Ning, Huang, Mei‐Ping, Wu, Yi‐Long, Zhuang, Jian, Zhong, Wen‐Zhao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley & Sons Australia, Ltd 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7471015/
https://www.ncbi.nlm.nih.gov/pubmed/32686309
http://dx.doi.org/10.1111/1759-7714.13550
_version_ 1783578692542267392
author Fu, Rui
Chai, Yun‐Fei
Zhang, Jia‐Tao
Zhang, Tao
Chen, Xiao‐Kun
Dong, Song
Yan, Hong‐Hong
Yang, Xue‐Ning
Huang, Mei‐Ping
Wu, Yi‐Long
Zhuang, Jian
Zhong, Wen‐Zhao
author_facet Fu, Rui
Chai, Yun‐Fei
Zhang, Jia‐Tao
Zhang, Tao
Chen, Xiao‐Kun
Dong, Song
Yan, Hong‐Hong
Yang, Xue‐Ning
Huang, Mei‐Ping
Wu, Yi‐Long
Zhuang, Jian
Zhong, Wen‐Zhao
author_sort Fu, Rui
collection PubMed
description BACKGROUND: Localization of small pulmonary nodules is an inevitable challenge for the thoracic surgeon. This study aimed to investigate the accuracy of three‐dimensional (3D) printing technology for localizing small pulmonary nodules, especially ground‐glass nodules (GGNs). METHODS: This study enrolled patients with peripheral small pulmonary nodules (≤ 2 cm) who required preoperative localization. In the comparison period, patients underwent both computed tomography‐guided (CT‐G) and 3D‐printing template guided (3D‐G) localization to compare the accuracies of the two methods. In the testing period, the 3D‐printing technique was implemented alone. The 3D‐printing physical navigational template was designed based on data from perioperative CT images. Clinical data, imaging data, surgical data, and evaluation index were collected for further analysis. The learning curve of the 3D‐printing localization technique was assessed using cumulative sum (CUSUM) analysis and multiple linear regression analysis. RESULTS: In the comparison period (n = 14), the success rates of CT‐G and 3D‐G were 100% and 92.9% (P = 0.31), respectively; in the testing period (n = 23), the success rate of 3D‐G was 95.6%. The localization times of CT‐G, 3D‐G (comparison), and 3D‐G (testing) were 23.6 ± 5.3, 19.3 ± 6.8, and 9.8 ± 4.6 minutes, respectively. The CUSUM learning curve was modeled using the equation: Y = 0.48X(2) − 0.013X − 0.454 (R(2) = 0.89). The learning curve was composed of two phases, phase 1 (the initial 20 patients) and phase 2 (the remaining 17 patients). CONCLUSIONS: 3D printing localization has adequate accuracy and is a feasible and accessible strategy for use in localizing small pulmonary nodules, especially in right upper lobe. The use of this technique could facilitate lung nodule localization prior to surgery.
format Online
Article
Text
id pubmed-7471015
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher John Wiley & Sons Australia, Ltd
record_format MEDLINE/PubMed
spelling pubmed-74710152020-09-09 Three‐dimensional printed navigational template for localizing small pulmonary nodules: A case‐controlled study Fu, Rui Chai, Yun‐Fei Zhang, Jia‐Tao Zhang, Tao Chen, Xiao‐Kun Dong, Song Yan, Hong‐Hong Yang, Xue‐Ning Huang, Mei‐Ping Wu, Yi‐Long Zhuang, Jian Zhong, Wen‐Zhao Thorac Cancer Brief Reports BACKGROUND: Localization of small pulmonary nodules is an inevitable challenge for the thoracic surgeon. This study aimed to investigate the accuracy of three‐dimensional (3D) printing technology for localizing small pulmonary nodules, especially ground‐glass nodules (GGNs). METHODS: This study enrolled patients with peripheral small pulmonary nodules (≤ 2 cm) who required preoperative localization. In the comparison period, patients underwent both computed tomography‐guided (CT‐G) and 3D‐printing template guided (3D‐G) localization to compare the accuracies of the two methods. In the testing period, the 3D‐printing technique was implemented alone. The 3D‐printing physical navigational template was designed based on data from perioperative CT images. Clinical data, imaging data, surgical data, and evaluation index were collected for further analysis. The learning curve of the 3D‐printing localization technique was assessed using cumulative sum (CUSUM) analysis and multiple linear regression analysis. RESULTS: In the comparison period (n = 14), the success rates of CT‐G and 3D‐G were 100% and 92.9% (P = 0.31), respectively; in the testing period (n = 23), the success rate of 3D‐G was 95.6%. The localization times of CT‐G, 3D‐G (comparison), and 3D‐G (testing) were 23.6 ± 5.3, 19.3 ± 6.8, and 9.8 ± 4.6 minutes, respectively. The CUSUM learning curve was modeled using the equation: Y = 0.48X(2) − 0.013X − 0.454 (R(2) = 0.89). The learning curve was composed of two phases, phase 1 (the initial 20 patients) and phase 2 (the remaining 17 patients). CONCLUSIONS: 3D printing localization has adequate accuracy and is a feasible and accessible strategy for use in localizing small pulmonary nodules, especially in right upper lobe. The use of this technique could facilitate lung nodule localization prior to surgery. John Wiley & Sons Australia, Ltd 2020-07-19 2020-09 /pmc/articles/PMC7471015/ /pubmed/32686309 http://dx.doi.org/10.1111/1759-7714.13550 Text en © 2020 The Authors. Thoracic Cancer published by China Lung Oncology Group and John Wiley & Sons Australia, Ltd This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc-nd/4.0/ License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Brief Reports
Fu, Rui
Chai, Yun‐Fei
Zhang, Jia‐Tao
Zhang, Tao
Chen, Xiao‐Kun
Dong, Song
Yan, Hong‐Hong
Yang, Xue‐Ning
Huang, Mei‐Ping
Wu, Yi‐Long
Zhuang, Jian
Zhong, Wen‐Zhao
Three‐dimensional printed navigational template for localizing small pulmonary nodules: A case‐controlled study
title Three‐dimensional printed navigational template for localizing small pulmonary nodules: A case‐controlled study
title_full Three‐dimensional printed navigational template for localizing small pulmonary nodules: A case‐controlled study
title_fullStr Three‐dimensional printed navigational template for localizing small pulmonary nodules: A case‐controlled study
title_full_unstemmed Three‐dimensional printed navigational template for localizing small pulmonary nodules: A case‐controlled study
title_short Three‐dimensional printed navigational template for localizing small pulmonary nodules: A case‐controlled study
title_sort three‐dimensional printed navigational template for localizing small pulmonary nodules: a case‐controlled study
topic Brief Reports
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7471015/
https://www.ncbi.nlm.nih.gov/pubmed/32686309
http://dx.doi.org/10.1111/1759-7714.13550
work_keys_str_mv AT furui threedimensionalprintednavigationaltemplateforlocalizingsmallpulmonarynodulesacasecontrolledstudy
AT chaiyunfei threedimensionalprintednavigationaltemplateforlocalizingsmallpulmonarynodulesacasecontrolledstudy
AT zhangjiatao threedimensionalprintednavigationaltemplateforlocalizingsmallpulmonarynodulesacasecontrolledstudy
AT zhangtao threedimensionalprintednavigationaltemplateforlocalizingsmallpulmonarynodulesacasecontrolledstudy
AT chenxiaokun threedimensionalprintednavigationaltemplateforlocalizingsmallpulmonarynodulesacasecontrolledstudy
AT dongsong threedimensionalprintednavigationaltemplateforlocalizingsmallpulmonarynodulesacasecontrolledstudy
AT yanhonghong threedimensionalprintednavigationaltemplateforlocalizingsmallpulmonarynodulesacasecontrolledstudy
AT yangxuening threedimensionalprintednavigationaltemplateforlocalizingsmallpulmonarynodulesacasecontrolledstudy
AT huangmeiping threedimensionalprintednavigationaltemplateforlocalizingsmallpulmonarynodulesacasecontrolledstudy
AT wuyilong threedimensionalprintednavigationaltemplateforlocalizingsmallpulmonarynodulesacasecontrolledstudy
AT zhuangjian threedimensionalprintednavigationaltemplateforlocalizingsmallpulmonarynodulesacasecontrolledstudy
AT zhongwenzhao threedimensionalprintednavigationaltemplateforlocalizingsmallpulmonarynodulesacasecontrolledstudy