Cargando…

Personalized Cup Positioning Guides Improved Cup Positioning and Hip Ranges of Motion in Robotic Assisted Total Hip Arthroplasty

OBJECTIVE: Precise hip cup positioning is essential for the prevention of component impingement and dislocation in robotic assisted total hip arthroplasty (THA). Currently, the robotic system uses a mechanical alignment guide (MAG) for cup placement, which is one-size-fits-all, and the optimal cup p...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Ruoyu, Zheng, Xiaojing, Xu, Tianze, Gong, Song, Liu, Shaokai, Han, Lizhi, Yang, Shuhua, Xu, Weihua
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7471602/
https://www.ncbi.nlm.nih.gov/pubmed/32974316
http://dx.doi.org/10.3389/fbioe.2020.00988
_version_ 1783578802955223040
author Wang, Ruoyu
Zheng, Xiaojing
Xu, Tianze
Gong, Song
Liu, Shaokai
Han, Lizhi
Yang, Shuhua
Xu, Weihua
author_facet Wang, Ruoyu
Zheng, Xiaojing
Xu, Tianze
Gong, Song
Liu, Shaokai
Han, Lizhi
Yang, Shuhua
Xu, Weihua
author_sort Wang, Ruoyu
collection PubMed
description OBJECTIVE: Precise hip cup positioning is essential for the prevention of component impingement and dislocation in robotic assisted total hip arthroplasty (THA). Currently, the robotic system uses a mechanical alignment guide (MAG) for cup placement, which is one-size-fits-all, and the optimal cup positioning is controversial. Robotic assisted THA has not used any personalized cup positioning guides. The goal of this study was to identify an optimal guide for cup placement in robotic assisted THA to improve prognosis and life quality after THA. MATERIALS AND METHODS: Pelvis and femoral CT data of 47 participants were retrospectively collected for preoperative planning of robotic THA. The universal MAG guide and three personalized guides, including acetabular rim labrum guide (ARLG), transverse acetabular ligament guide (TALG), and ischiatic-pubis line guide (IPLG), were used to pose cups in the acetabulum of each participant. The position of cups was evaluated by inclination and anteversion; the function of hip joints was evaluated by hip ranges of motion, including abduction, adduction, extension, flexion, internal rotation, and external rotation. RESULTS: In terms of cup positioning, ARLG provided a bigger cup inclination (p < 0.0001), while IPLG and TALG provided smaller cup inclination (p < 0.001) than MAG; the three personalized guides provided larger cup anteversion (p < 0.0001) than MAG. In terms of HROMs, compared with the use of MAG, the use of three personalized guides significantly decreased abduction (p < 0.0001), extension (p < 0.0001), and external rotation (p < 0.0001), but increased significantly flexion (p < 0.0001) and internal rotation (p < 0.0001); the use of ARLG significantly reduced adduction (p < 0.0001), but the use of IPLG and TALG increased adduction (p < 0.0001). CONCLUSION: Compared with MAG, personalized guides provided greater flexion and internal rotation, which may reduce the risk of posterior dislocation. Among the three personalized guides, IPLG is the most reliable one for the preoperative planning of robotic assisted THA.
format Online
Article
Text
id pubmed-7471602
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-74716022020-09-23 Personalized Cup Positioning Guides Improved Cup Positioning and Hip Ranges of Motion in Robotic Assisted Total Hip Arthroplasty Wang, Ruoyu Zheng, Xiaojing Xu, Tianze Gong, Song Liu, Shaokai Han, Lizhi Yang, Shuhua Xu, Weihua Front Bioeng Biotechnol Bioengineering and Biotechnology OBJECTIVE: Precise hip cup positioning is essential for the prevention of component impingement and dislocation in robotic assisted total hip arthroplasty (THA). Currently, the robotic system uses a mechanical alignment guide (MAG) for cup placement, which is one-size-fits-all, and the optimal cup positioning is controversial. Robotic assisted THA has not used any personalized cup positioning guides. The goal of this study was to identify an optimal guide for cup placement in robotic assisted THA to improve prognosis and life quality after THA. MATERIALS AND METHODS: Pelvis and femoral CT data of 47 participants were retrospectively collected for preoperative planning of robotic THA. The universal MAG guide and three personalized guides, including acetabular rim labrum guide (ARLG), transverse acetabular ligament guide (TALG), and ischiatic-pubis line guide (IPLG), were used to pose cups in the acetabulum of each participant. The position of cups was evaluated by inclination and anteversion; the function of hip joints was evaluated by hip ranges of motion, including abduction, adduction, extension, flexion, internal rotation, and external rotation. RESULTS: In terms of cup positioning, ARLG provided a bigger cup inclination (p < 0.0001), while IPLG and TALG provided smaller cup inclination (p < 0.001) than MAG; the three personalized guides provided larger cup anteversion (p < 0.0001) than MAG. In terms of HROMs, compared with the use of MAG, the use of three personalized guides significantly decreased abduction (p < 0.0001), extension (p < 0.0001), and external rotation (p < 0.0001), but increased significantly flexion (p < 0.0001) and internal rotation (p < 0.0001); the use of ARLG significantly reduced adduction (p < 0.0001), but the use of IPLG and TALG increased adduction (p < 0.0001). CONCLUSION: Compared with MAG, personalized guides provided greater flexion and internal rotation, which may reduce the risk of posterior dislocation. Among the three personalized guides, IPLG is the most reliable one for the preoperative planning of robotic assisted THA. Frontiers Media S.A. 2020-08-21 /pmc/articles/PMC7471602/ /pubmed/32974316 http://dx.doi.org/10.3389/fbioe.2020.00988 Text en Copyright © 2020 Wang, Zheng, Xu, Gong, Liu, Han, Yang and Xu. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Bioengineering and Biotechnology
Wang, Ruoyu
Zheng, Xiaojing
Xu, Tianze
Gong, Song
Liu, Shaokai
Han, Lizhi
Yang, Shuhua
Xu, Weihua
Personalized Cup Positioning Guides Improved Cup Positioning and Hip Ranges of Motion in Robotic Assisted Total Hip Arthroplasty
title Personalized Cup Positioning Guides Improved Cup Positioning and Hip Ranges of Motion in Robotic Assisted Total Hip Arthroplasty
title_full Personalized Cup Positioning Guides Improved Cup Positioning and Hip Ranges of Motion in Robotic Assisted Total Hip Arthroplasty
title_fullStr Personalized Cup Positioning Guides Improved Cup Positioning and Hip Ranges of Motion in Robotic Assisted Total Hip Arthroplasty
title_full_unstemmed Personalized Cup Positioning Guides Improved Cup Positioning and Hip Ranges of Motion in Robotic Assisted Total Hip Arthroplasty
title_short Personalized Cup Positioning Guides Improved Cup Positioning and Hip Ranges of Motion in Robotic Assisted Total Hip Arthroplasty
title_sort personalized cup positioning guides improved cup positioning and hip ranges of motion in robotic assisted total hip arthroplasty
topic Bioengineering and Biotechnology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7471602/
https://www.ncbi.nlm.nih.gov/pubmed/32974316
http://dx.doi.org/10.3389/fbioe.2020.00988
work_keys_str_mv AT wangruoyu personalizedcuppositioningguidesimprovedcuppositioningandhiprangesofmotioninroboticassistedtotalhiparthroplasty
AT zhengxiaojing personalizedcuppositioningguidesimprovedcuppositioningandhiprangesofmotioninroboticassistedtotalhiparthroplasty
AT xutianze personalizedcuppositioningguidesimprovedcuppositioningandhiprangesofmotioninroboticassistedtotalhiparthroplasty
AT gongsong personalizedcuppositioningguidesimprovedcuppositioningandhiprangesofmotioninroboticassistedtotalhiparthroplasty
AT liushaokai personalizedcuppositioningguidesimprovedcuppositioningandhiprangesofmotioninroboticassistedtotalhiparthroplasty
AT hanlizhi personalizedcuppositioningguidesimprovedcuppositioningandhiprangesofmotioninroboticassistedtotalhiparthroplasty
AT yangshuhua personalizedcuppositioningguidesimprovedcuppositioningandhiprangesofmotioninroboticassistedtotalhiparthroplasty
AT xuweihua personalizedcuppositioningguidesimprovedcuppositioningandhiprangesofmotioninroboticassistedtotalhiparthroplasty