Using the Redundant Convolutional Encoder–Decoder to Denoise QRS Complexes in ECG Signals Recorded with an Armband Wearable Device

Long-term electrocardiogram (ECG) recordings while performing normal daily routines are often corrupted with motion artifacts, which in turn, can result in the incorrect calculation of heart rates. Heart rates are important clinical information, as they can be used for analysis of heart-rate variabi...

Descripción completa

Detalles Bibliográficos
Autores principales: Reljin, Natasa, Lazaro, Jesus, Hossain, Md Billal, Noh, Yeon Sik, Cho, Chae Ho, Chon, Ki H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7472132/
https://www.ncbi.nlm.nih.gov/pubmed/32824420
http://dx.doi.org/10.3390/s20164611
_version_ 1783578918493618176
author Reljin, Natasa
Lazaro, Jesus
Hossain, Md Billal
Noh, Yeon Sik
Cho, Chae Ho
Chon, Ki H.
author_facet Reljin, Natasa
Lazaro, Jesus
Hossain, Md Billal
Noh, Yeon Sik
Cho, Chae Ho
Chon, Ki H.
author_sort Reljin, Natasa
collection PubMed
description Long-term electrocardiogram (ECG) recordings while performing normal daily routines are often corrupted with motion artifacts, which in turn, can result in the incorrect calculation of heart rates. Heart rates are important clinical information, as they can be used for analysis of heart-rate variability and detection of cardiac arrhythmias. In this study, we present an algorithm for denoising ECG signals acquired with a wearable armband device. The armband was worn on the upper left arm by one male participant, and we simultaneously recorded three ECG channels for 24 h. We extracted 10-s sequences from armband recordings corrupted with added noise and motion artifacts. Denoising was performed using the redundant convolutional encoder–decoder (R-CED), a fully convolutional network. We measured the performance by detecting R-peaks in clean, noisy, and denoised sequences and by calculating signal quality indices: signal-to-noise ratio (SNR), ratio of power, and cross-correlation with respect to the clean sequences. The percent of correctly detected R-peaks in denoised sequences was higher than in sequences corrupted with either added noise (70–100% vs. 34–97%) or motion artifacts (91.86% vs. 61.16%). There was notable improvement in SNR values after denoising for signals with noise added (7–19 dB), and when sequences were corrupted with motion artifacts (0.39 dB). The ratio of power for noisy sequences was significantly lower when compared to both clean and denoised sequences. Similarly, cross-correlation between noisy and clean sequences was significantly lower than between denoised and clean sequences. Moreover, we tested our denoising algorithm on 60-s sequences extracted from recordings from the Massachusetts Institute of Technology-Beth Israel Hospital (MIT-BIH) arrhythmia database and obtained improvement in SNR values of 7.08 ± 0.25 dB (mean ± standard deviation (sd)). These results from a diverse set of data suggest that the proposed denoising algorithm improves the quality of the signal and can potentially be applied to most ECG measurement devices.
format Online
Article
Text
id pubmed-7472132
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-74721322020-09-04 Using the Redundant Convolutional Encoder–Decoder to Denoise QRS Complexes in ECG Signals Recorded with an Armband Wearable Device Reljin, Natasa Lazaro, Jesus Hossain, Md Billal Noh, Yeon Sik Cho, Chae Ho Chon, Ki H. Sensors (Basel) Article Long-term electrocardiogram (ECG) recordings while performing normal daily routines are often corrupted with motion artifacts, which in turn, can result in the incorrect calculation of heart rates. Heart rates are important clinical information, as they can be used for analysis of heart-rate variability and detection of cardiac arrhythmias. In this study, we present an algorithm for denoising ECG signals acquired with a wearable armband device. The armband was worn on the upper left arm by one male participant, and we simultaneously recorded three ECG channels for 24 h. We extracted 10-s sequences from armband recordings corrupted with added noise and motion artifacts. Denoising was performed using the redundant convolutional encoder–decoder (R-CED), a fully convolutional network. We measured the performance by detecting R-peaks in clean, noisy, and denoised sequences and by calculating signal quality indices: signal-to-noise ratio (SNR), ratio of power, and cross-correlation with respect to the clean sequences. The percent of correctly detected R-peaks in denoised sequences was higher than in sequences corrupted with either added noise (70–100% vs. 34–97%) or motion artifacts (91.86% vs. 61.16%). There was notable improvement in SNR values after denoising for signals with noise added (7–19 dB), and when sequences were corrupted with motion artifacts (0.39 dB). The ratio of power for noisy sequences was significantly lower when compared to both clean and denoised sequences. Similarly, cross-correlation between noisy and clean sequences was significantly lower than between denoised and clean sequences. Moreover, we tested our denoising algorithm on 60-s sequences extracted from recordings from the Massachusetts Institute of Technology-Beth Israel Hospital (MIT-BIH) arrhythmia database and obtained improvement in SNR values of 7.08 ± 0.25 dB (mean ± standard deviation (sd)). These results from a diverse set of data suggest that the proposed denoising algorithm improves the quality of the signal and can potentially be applied to most ECG measurement devices. MDPI 2020-08-17 /pmc/articles/PMC7472132/ /pubmed/32824420 http://dx.doi.org/10.3390/s20164611 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Reljin, Natasa
Lazaro, Jesus
Hossain, Md Billal
Noh, Yeon Sik
Cho, Chae Ho
Chon, Ki H.
Using the Redundant Convolutional Encoder–Decoder to Denoise QRS Complexes in ECG Signals Recorded with an Armband Wearable Device
title Using the Redundant Convolutional Encoder–Decoder to Denoise QRS Complexes in ECG Signals Recorded with an Armband Wearable Device
title_full Using the Redundant Convolutional Encoder–Decoder to Denoise QRS Complexes in ECG Signals Recorded with an Armband Wearable Device
title_fullStr Using the Redundant Convolutional Encoder–Decoder to Denoise QRS Complexes in ECG Signals Recorded with an Armband Wearable Device
title_full_unstemmed Using the Redundant Convolutional Encoder–Decoder to Denoise QRS Complexes in ECG Signals Recorded with an Armband Wearable Device
title_short Using the Redundant Convolutional Encoder–Decoder to Denoise QRS Complexes in ECG Signals Recorded with an Armband Wearable Device
title_sort using the redundant convolutional encoder–decoder to denoise qrs complexes in ecg signals recorded with an armband wearable device
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7472132/
https://www.ncbi.nlm.nih.gov/pubmed/32824420
http://dx.doi.org/10.3390/s20164611
work_keys_str_mv AT reljinnatasa usingtheredundantconvolutionalencoderdecodertodenoiseqrscomplexesinecgsignalsrecordedwithanarmbandwearabledevice
AT lazarojesus usingtheredundantconvolutionalencoderdecodertodenoiseqrscomplexesinecgsignalsrecordedwithanarmbandwearabledevice
AT hossainmdbillal usingtheredundantconvolutionalencoderdecodertodenoiseqrscomplexesinecgsignalsrecordedwithanarmbandwearabledevice
AT nohyeonsik usingtheredundantconvolutionalencoderdecodertodenoiseqrscomplexesinecgsignalsrecordedwithanarmbandwearabledevice
AT chochaeho usingtheredundantconvolutionalencoderdecodertodenoiseqrscomplexesinecgsignalsrecordedwithanarmbandwearabledevice
AT chonkih usingtheredundantconvolutionalencoderdecodertodenoiseqrscomplexesinecgsignalsrecordedwithanarmbandwearabledevice