Cargando…

Evaluation of a Fully Automatic Measurement of Short-Term Variability of Repolarization on Intracardiac Electrograms in the Chronic Atrioventricular Block Dog

Background: Short-term variability (STV) of repolarization of the monophasic action potential duration (MAPD) or activation recovery interval (ARI) on the intracardiac electrogram (EGM) increases abruptly prior to the occurrence of ventricular arrhythmias in the chronic AV-block (CAVB) dog model. Th...

Descripción completa

Detalles Bibliográficos
Autores principales: Smoczyńska, Agnieszka, Sprenkeler, David J., Aranda, Alfonso, Beekman, Jet D.M., Bossu, Alexandre, Dunnink, Albert, Wijers, Sofieke C., Stegemann, Berthold, Meine, Mathias, Vos, Marc A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7472439/
https://www.ncbi.nlm.nih.gov/pubmed/32973549
http://dx.doi.org/10.3389/fphys.2020.01005
Descripción
Sumario:Background: Short-term variability (STV) of repolarization of the monophasic action potential duration (MAPD) or activation recovery interval (ARI) on the intracardiac electrogram (EGM) increases abruptly prior to the occurrence of ventricular arrhythmias in the chronic AV-block (CAVB) dog model. Therefore, this parameter might be suitable for continuous monitoring of imminent arrhythmias using the EGM stored on an implanted device. However, 24/7 monitoring would require automatic STV(ARI) measurement by the device. Objective: To evaluate a newly developed automatic measurement of STV(ARI) for prediction of dofetilide-induced torsade de pointes (TdP) arrhythmias in the CAVB-dog. Methods: Two retrospective analyses were done on data from recently performed dog experiments. (1) In seven anesthetized CAVB-dogs, the new automatic STV(ARI) method was compared with the gold standard STV(MAPD) at baseline and after dofetilide administration (0.025 mg/kg in 5 min). (2) The predictive value of the automatic method was compared to currently used STV(ARI) methods, i.e., slope method and fiducial segment averaging (FSA) method, in 11 inducible (≥3 TdP arrhythmias) and 10 non-inducible CAVB-dogs. Results: (1) The automatic measurement of STV(ARI) had good correlation with STV(MAPD) (r(2) = 0.89; p < 0.001). Bland-Altman analysis showed a small bias of 0.06 ms with limits of agreement between −0.63 and 0.76 ms. (2) STV(ARI) of all three methods was significantly different between inducible and non-inducible dogs after dofetilide. The automatic method showed the highest predictive performance with an area under the ROC-curve of 0.93, compared to 0.85 and 0.87 of the slope and FSA methods, respectively. With a threshold of STV set at 1.69 ms, STV(ARI) measured with the automatic method had a sensitivity of 0.91 and specificity of 0.90 in differentiating inducible from non-inducible subjects. Conclusion: We developed a fully-automatic method for measurement of STV(ARI) on the intracardiac EGM that can accurately predict the occurrence of ventricular arrhythmias in the CAVB-dog. Future integration of this method into implantable devices could provide the opportunity for 24/7 monitoring of arrhythmic risk.