Cargando…

Preliminary Experiment Using Sensors for Cow Health Monitoring after Surgical Treatment for the Left Displacement of the Abomasum

The aim of the current study was to determine the effectiveness of two surgical techniques regarding cow respiratory rates, heart rates, and rumination time using two sensors: an experimental device created by the Institute of Biomedical Engineering of Kaunas University of Technology (Lithuania) and...

Descripción completa

Detalles Bibliográficos
Autores principales: Antanaitis, Ramūnas, Juozaitienė, Vida, Televičius, Mindaugas, Malašauskienė, Dovilė, Merkis, Mantvydas, Merkis, Eitvydas, Baumgartner, Walter
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7472475/
https://www.ncbi.nlm.nih.gov/pubmed/32784759
http://dx.doi.org/10.3390/s20164416
_version_ 1783578991826829312
author Antanaitis, Ramūnas
Juozaitienė, Vida
Televičius, Mindaugas
Malašauskienė, Dovilė
Merkis, Mantvydas
Merkis, Eitvydas
Baumgartner, Walter
author_facet Antanaitis, Ramūnas
Juozaitienė, Vida
Televičius, Mindaugas
Malašauskienė, Dovilė
Merkis, Mantvydas
Merkis, Eitvydas
Baumgartner, Walter
author_sort Antanaitis, Ramūnas
collection PubMed
description The aim of the current study was to determine the effectiveness of two surgical techniques regarding cow respiratory rates, heart rates, and rumination time using two sensors: an experimental device created by the Institute of Biomedical Engineering of Kaunas University of Technology (Lithuania) and the Hi-Tag rumination monitoring system (SCR) produced by SCR Engineers Ltd., Netanya, Israel. The cows were divided into two groups: the PA1 group, containing cows treated by percutaneous abomasopexy (n = 10), and the RSO2 group, containing cows treated by right side omentopexy (n = 8). For the control group (KH), according to the principle of analogs (number of lactations, breed, and days in milk), we selected clinically healthy cows (n = 9). After the surgical treatment for the abomasal displacement, the experimental device was applied for the recording of the heart and breathing rates, 12 h tracking of the rumination time was implemented using the SCR, and the body temperature was measured. After 12 h, the blood was taken for biochemical and morphological tests. With the help of experimental sensors, we found that the more efficient abomasal displacement surgical method was the right side omentopexy: During the first 12 h after right side omentopexy, we found a 5.19 beats/min lower (1.10 times lower) average value of the respiratory rate, a 1.13 times higher level of the heart rate, a 0.15 °C higher temperature, and a 3.29 times lower rumination time compared to the clinically healthy cows. During the first 12 h after percutaneous abomasopexy, we found a 5.19 beats/min higher (1.07 times) average value of heart rate, a 0.02 °C higher temperature, a 6.21 times lower rumination time, and a 0.12 beats/min lower (1.01 times lower) average value of respiratory rate compared to the clinically healthy cows.
format Online
Article
Text
id pubmed-7472475
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-74724752020-09-17 Preliminary Experiment Using Sensors for Cow Health Monitoring after Surgical Treatment for the Left Displacement of the Abomasum Antanaitis, Ramūnas Juozaitienė, Vida Televičius, Mindaugas Malašauskienė, Dovilė Merkis, Mantvydas Merkis, Eitvydas Baumgartner, Walter Sensors (Basel) Article The aim of the current study was to determine the effectiveness of two surgical techniques regarding cow respiratory rates, heart rates, and rumination time using two sensors: an experimental device created by the Institute of Biomedical Engineering of Kaunas University of Technology (Lithuania) and the Hi-Tag rumination monitoring system (SCR) produced by SCR Engineers Ltd., Netanya, Israel. The cows were divided into two groups: the PA1 group, containing cows treated by percutaneous abomasopexy (n = 10), and the RSO2 group, containing cows treated by right side omentopexy (n = 8). For the control group (KH), according to the principle of analogs (number of lactations, breed, and days in milk), we selected clinically healthy cows (n = 9). After the surgical treatment for the abomasal displacement, the experimental device was applied for the recording of the heart and breathing rates, 12 h tracking of the rumination time was implemented using the SCR, and the body temperature was measured. After 12 h, the blood was taken for biochemical and morphological tests. With the help of experimental sensors, we found that the more efficient abomasal displacement surgical method was the right side omentopexy: During the first 12 h after right side omentopexy, we found a 5.19 beats/min lower (1.10 times lower) average value of the respiratory rate, a 1.13 times higher level of the heart rate, a 0.15 °C higher temperature, and a 3.29 times lower rumination time compared to the clinically healthy cows. During the first 12 h after percutaneous abomasopexy, we found a 5.19 beats/min higher (1.07 times) average value of heart rate, a 0.02 °C higher temperature, a 6.21 times lower rumination time, and a 0.12 beats/min lower (1.01 times lower) average value of respiratory rate compared to the clinically healthy cows. MDPI 2020-08-07 /pmc/articles/PMC7472475/ /pubmed/32784759 http://dx.doi.org/10.3390/s20164416 Text en © 2020 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Antanaitis, Ramūnas
Juozaitienė, Vida
Televičius, Mindaugas
Malašauskienė, Dovilė
Merkis, Mantvydas
Merkis, Eitvydas
Baumgartner, Walter
Preliminary Experiment Using Sensors for Cow Health Monitoring after Surgical Treatment for the Left Displacement of the Abomasum
title Preliminary Experiment Using Sensors for Cow Health Monitoring after Surgical Treatment for the Left Displacement of the Abomasum
title_full Preliminary Experiment Using Sensors for Cow Health Monitoring after Surgical Treatment for the Left Displacement of the Abomasum
title_fullStr Preliminary Experiment Using Sensors for Cow Health Monitoring after Surgical Treatment for the Left Displacement of the Abomasum
title_full_unstemmed Preliminary Experiment Using Sensors for Cow Health Monitoring after Surgical Treatment for the Left Displacement of the Abomasum
title_short Preliminary Experiment Using Sensors for Cow Health Monitoring after Surgical Treatment for the Left Displacement of the Abomasum
title_sort preliminary experiment using sensors for cow health monitoring after surgical treatment for the left displacement of the abomasum
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7472475/
https://www.ncbi.nlm.nih.gov/pubmed/32784759
http://dx.doi.org/10.3390/s20164416
work_keys_str_mv AT antanaitisramunas preliminaryexperimentusingsensorsforcowhealthmonitoringaftersurgicaltreatmentfortheleftdisplacementoftheabomasum
AT juozaitienevida preliminaryexperimentusingsensorsforcowhealthmonitoringaftersurgicaltreatmentfortheleftdisplacementoftheabomasum
AT televiciusmindaugas preliminaryexperimentusingsensorsforcowhealthmonitoringaftersurgicaltreatmentfortheleftdisplacementoftheabomasum
AT malasauskienedovile preliminaryexperimentusingsensorsforcowhealthmonitoringaftersurgicaltreatmentfortheleftdisplacementoftheabomasum
AT merkismantvydas preliminaryexperimentusingsensorsforcowhealthmonitoringaftersurgicaltreatmentfortheleftdisplacementoftheabomasum
AT merkiseitvydas preliminaryexperimentusingsensorsforcowhealthmonitoringaftersurgicaltreatmentfortheleftdisplacementoftheabomasum
AT baumgartnerwalter preliminaryexperimentusingsensorsforcowhealthmonitoringaftersurgicaltreatmentfortheleftdisplacementoftheabomasum