Cargando…

Membrane-assisted radiant cooling for expanding thermal comfort zones globally without air conditioning

We present results of a radiant cooling system that made the hot and humid tropical climate of Singapore feel cool and comfortable. Thermal radiation exchange between occupants and surfaces in the built environment can augment thermal comfort. The lack of widespread commercial adoption of radiant-co...

Descripción completa

Detalles Bibliográficos
Autores principales: Teitelbaum, Eric, Chen, Kian Wee, Aviv, Dorit, Bradford, Kipp, Ruefenacht, Lea, Sheppard, Denon, Teitelbaum, Megan, Meggers, Forrest, Pantelic, Jovan, Rysanek, Adam
Formato: Online Artículo Texto
Lenguaje:English
Publicado: National Academy of Sciences 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7474686/
https://www.ncbi.nlm.nih.gov/pubmed/32817481
http://dx.doi.org/10.1073/pnas.2001678117
Descripción
Sumario:We present results of a radiant cooling system that made the hot and humid tropical climate of Singapore feel cool and comfortable. Thermal radiation exchange between occupants and surfaces in the built environment can augment thermal comfort. The lack of widespread commercial adoption of radiant-cooling technologies is due to two widely held views: 1) The low temperature required for radiant cooling in humid environments will form condensation; and 2) cold surfaces will still cool adjacent air via convection, limiting overall radiant-cooling effectiveness. This work directly challenges these views and provides proof-of-concept solutions examined for a transient thermal-comfort scenario. We constructed a demonstrative outdoor radiant-cooling pavilion in Singapore that used an infrared-transparent, low-density polyethylene membrane to provide radiant cooling at temperatures below the dew point. Test subjects who experienced the pavilion (n = 37) reported a “satisfactory” thermal sensation 79% of the time, despite experiencing 29.6 [Formula: see text] 0.9 °C air at 66.5 [Formula: see text] 5% relative humidity and with low air movement of 0.26 [Formula: see text] 0.18 m [Formula: see text] s(−1). Comfort was achieved with a coincident mean radiant temperature of 23.9 [Formula: see text] 0.8 °C, requiring a chilled water-supply temperature of 17.0 [Formula: see text] 1.8 °C. The pavilion operated successfully without any observed condensation on exposed surfaces, despite an observed dew-point temperature of 23.7 [Formula: see text] 0.7 °C. The coldest conditions observed without condensation used a chilled water-supply temperature 12.7 °C below the dew point, which resulted in a mean radiant temperature 3.6 °C below the dew point.