Cargando…

Multiacquisition Variable-Resonance Image Combination Magnetic Resonance Imaging Used to Study Detailed Bone Apposition and Fixation of an Additively Manufactured Cementless Acetabular Shell

BACKGROUND: The ability to utilize magnetic resonance imaging (MRI) to assess bony fixation in 3 dimensions may allow a better understanding of the implant design and bony integration. We hypothesized that a new 3-dimensionally printed cementless highly porous acetabular component (Stryker Trident I...

Descripción completa

Detalles Bibliográficos
Autores principales: Alamanda, Vignesh K., Demartino, Ivan, Potter, Hollis G., Koff, Matthew F., Lin, Bin, Muskat, Ahava, Westrich, Geoffrey H.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7475047/
https://www.ncbi.nlm.nih.gov/pubmed/32923552
http://dx.doi.org/10.1016/j.artd.2020.07.019
_version_ 1783579441774985216
author Alamanda, Vignesh K.
Demartino, Ivan
Potter, Hollis G.
Koff, Matthew F.
Lin, Bin
Muskat, Ahava
Westrich, Geoffrey H.
author_facet Alamanda, Vignesh K.
Demartino, Ivan
Potter, Hollis G.
Koff, Matthew F.
Lin, Bin
Muskat, Ahava
Westrich, Geoffrey H.
author_sort Alamanda, Vignesh K.
collection PubMed
description BACKGROUND: The ability to utilize magnetic resonance imaging (MRI) to assess bony fixation in 3 dimensions may allow a better understanding of the implant design and bony integration. We hypothesized that a new 3-dimensionally printed cementless highly porous acetabular component (Stryker Trident II Tritanium(TM)) would show better fixation than an earlier cup from the same manufacturer as assessed by the noninvasive technique of multispectral MRI. METHODS: Multiacquisition variable-resonance image combination selective metal suppression MRI was performed in 19 patients implanted with a new 3-dimensionally printed cup and 20 patients who had received a previous-generation cup from the same manufacturer at 1-year follow-up. Each cup was graded globally as well as by 9 specific zones. Integration grades were performed for each zone: 0, full bone integration; 1, fibrous membrane present; 2, osteolysis; and 3, fluid present. A mixed-effects logistic regression model was used to compare fixation between the 2 groups. RESULTS: All cups in both cohorts showed greater than 90% estimated global bony integration (3-dimensionally printed cups, 99.4%; regular cups 91.6%) with no osteolysis or fluid observed in any cup. The 3-dimensionally printed cup had 1 of 171 zones (0.6%) graded as fibrous membrane present, while the 2-dimensional group had 15 of 180 zones (8.3%) graded as fibrous. Of note, screw hole regions were omitted but may be read as fibrous membrane areas. CONCLUSION: Using multiacquisition variable-resonance image combination selective MRI, our analysis showed greater osteointegration and less fibrous membrane formation in the 3-dimensionally printed cups than the control group at 1-year follow-up.
format Online
Article
Text
id pubmed-7475047
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-74750472020-09-11 Multiacquisition Variable-Resonance Image Combination Magnetic Resonance Imaging Used to Study Detailed Bone Apposition and Fixation of an Additively Manufactured Cementless Acetabular Shell Alamanda, Vignesh K. Demartino, Ivan Potter, Hollis G. Koff, Matthew F. Lin, Bin Muskat, Ahava Westrich, Geoffrey H. Arthroplast Today Original Research BACKGROUND: The ability to utilize magnetic resonance imaging (MRI) to assess bony fixation in 3 dimensions may allow a better understanding of the implant design and bony integration. We hypothesized that a new 3-dimensionally printed cementless highly porous acetabular component (Stryker Trident II Tritanium(TM)) would show better fixation than an earlier cup from the same manufacturer as assessed by the noninvasive technique of multispectral MRI. METHODS: Multiacquisition variable-resonance image combination selective metal suppression MRI was performed in 19 patients implanted with a new 3-dimensionally printed cup and 20 patients who had received a previous-generation cup from the same manufacturer at 1-year follow-up. Each cup was graded globally as well as by 9 specific zones. Integration grades were performed for each zone: 0, full bone integration; 1, fibrous membrane present; 2, osteolysis; and 3, fluid present. A mixed-effects logistic regression model was used to compare fixation between the 2 groups. RESULTS: All cups in both cohorts showed greater than 90% estimated global bony integration (3-dimensionally printed cups, 99.4%; regular cups 91.6%) with no osteolysis or fluid observed in any cup. The 3-dimensionally printed cup had 1 of 171 zones (0.6%) graded as fibrous membrane present, while the 2-dimensional group had 15 of 180 zones (8.3%) graded as fibrous. Of note, screw hole regions were omitted but may be read as fibrous membrane areas. CONCLUSION: Using multiacquisition variable-resonance image combination selective MRI, our analysis showed greater osteointegration and less fibrous membrane formation in the 3-dimensionally printed cups than the control group at 1-year follow-up. Elsevier 2020-08-26 /pmc/articles/PMC7475047/ /pubmed/32923552 http://dx.doi.org/10.1016/j.artd.2020.07.019 Text en © 2020 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Research
Alamanda, Vignesh K.
Demartino, Ivan
Potter, Hollis G.
Koff, Matthew F.
Lin, Bin
Muskat, Ahava
Westrich, Geoffrey H.
Multiacquisition Variable-Resonance Image Combination Magnetic Resonance Imaging Used to Study Detailed Bone Apposition and Fixation of an Additively Manufactured Cementless Acetabular Shell
title Multiacquisition Variable-Resonance Image Combination Magnetic Resonance Imaging Used to Study Detailed Bone Apposition and Fixation of an Additively Manufactured Cementless Acetabular Shell
title_full Multiacquisition Variable-Resonance Image Combination Magnetic Resonance Imaging Used to Study Detailed Bone Apposition and Fixation of an Additively Manufactured Cementless Acetabular Shell
title_fullStr Multiacquisition Variable-Resonance Image Combination Magnetic Resonance Imaging Used to Study Detailed Bone Apposition and Fixation of an Additively Manufactured Cementless Acetabular Shell
title_full_unstemmed Multiacquisition Variable-Resonance Image Combination Magnetic Resonance Imaging Used to Study Detailed Bone Apposition and Fixation of an Additively Manufactured Cementless Acetabular Shell
title_short Multiacquisition Variable-Resonance Image Combination Magnetic Resonance Imaging Used to Study Detailed Bone Apposition and Fixation of an Additively Manufactured Cementless Acetabular Shell
title_sort multiacquisition variable-resonance image combination magnetic resonance imaging used to study detailed bone apposition and fixation of an additively manufactured cementless acetabular shell
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7475047/
https://www.ncbi.nlm.nih.gov/pubmed/32923552
http://dx.doi.org/10.1016/j.artd.2020.07.019
work_keys_str_mv AT alamandavigneshk multiacquisitionvariableresonanceimagecombinationmagneticresonanceimagingusedtostudydetailedboneappositionandfixationofanadditivelymanufacturedcementlessacetabularshell
AT demartinoivan multiacquisitionvariableresonanceimagecombinationmagneticresonanceimagingusedtostudydetailedboneappositionandfixationofanadditivelymanufacturedcementlessacetabularshell
AT potterhollisg multiacquisitionvariableresonanceimagecombinationmagneticresonanceimagingusedtostudydetailedboneappositionandfixationofanadditivelymanufacturedcementlessacetabularshell
AT koffmatthewf multiacquisitionvariableresonanceimagecombinationmagneticresonanceimagingusedtostudydetailedboneappositionandfixationofanadditivelymanufacturedcementlessacetabularshell
AT linbin multiacquisitionvariableresonanceimagecombinationmagneticresonanceimagingusedtostudydetailedboneappositionandfixationofanadditivelymanufacturedcementlessacetabularshell
AT muskatahava multiacquisitionvariableresonanceimagecombinationmagneticresonanceimagingusedtostudydetailedboneappositionandfixationofanadditivelymanufacturedcementlessacetabularshell
AT westrichgeoffreyh multiacquisitionvariableresonanceimagecombinationmagneticresonanceimagingusedtostudydetailedboneappositionandfixationofanadditivelymanufacturedcementlessacetabularshell