Cargando…

Analysis of the guidance value of 3D ultrasound in evaluating endometrial receptivity for frozen-thawed embryo transfer in patients with repeated implantation failure

BACKGROUND: Repeated implantation failure (RIF) is currently believed by some scholars to be mainly related to the poor endometrial receptivity. Three-dimensional (3D) ultrasound, as a noninvasive examination, has attracted the most attention. This paper further discusses whether 3D ultrasound of th...

Descripción completa

Detalles Bibliográficos
Autores principales: Tong, Ruiqing, Zhou, Ying, He, Qi, Zhuang, Yanyan, Zhou, Weiqin, Xia, Fei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: AME Publishing Company 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7475420/
https://www.ncbi.nlm.nih.gov/pubmed/32953744
http://dx.doi.org/10.21037/atm-20-5463
_version_ 1783579500952420352
author Tong, Ruiqing
Zhou, Ying
He, Qi
Zhuang, Yanyan
Zhou, Weiqin
Xia, Fei
author_facet Tong, Ruiqing
Zhou, Ying
He, Qi
Zhuang, Yanyan
Zhou, Weiqin
Xia, Fei
author_sort Tong, Ruiqing
collection PubMed
description BACKGROUND: Repeated implantation failure (RIF) is currently believed by some scholars to be mainly related to the poor endometrial receptivity. Three-dimensional (3D) ultrasound, as a noninvasive examination, has attracted the most attention. This paper further discusses whether 3D ultrasound of the endometrial receptivity index has guidance value in the evaluation of pregnancy outcomes in patients with RIF following frozen-thawed embryo transfer. METHODS: A total of 79 patients with RIF were retrospectively analyzed. These 79 patients which were confirmed by the transvaginal ultrasonography detection comprised 36 cases of intrauterine pregnancy, which were included in the pregnancy group, and 43 cases with biochemical pregnancy (the HCG in blood or urine is only transient and can be detected by clinical biochemical methods. The pregnancy sac cannot be seen under ultrasound) or negative results of human chorionic gonadotropin (HCG) examination, which were included in the non-pregnancy group. The endometrial thickness, uterine volume, sub-endometrial blood flow type, pulsatility index (PI) and resistance index (RI) of the spiral artery; the RI and PI of the uterine artery; and the peak systolic velocity/end diastolic velocity (S/D) of the two groups were measured and analyzed. RESULTS: (I) There were no significant differences in the age, infertility years, body mass index (BMI), anti-Müllerian hormone (AMH), endometrial thickness on the hCG injection day, estradiol (E2), and progesterone (P) between the pregnant and non-pregnant groups (P>0.05). (II) There were no significant differences in the endometrial thickness, uterine volume, and RI and PI of the uterine artery on the day before the implantation between the two groups (P>0.05). (III) There was statistical difference in the sum of the S/D of the two uterine arteries between the two groups (P<0.05) with a cutoff value of 14.47 (P<0.05). (IV) The RI and PI of the spiral artery in the non-pregnancy group were lower than those in the pregnancy group, and the difference was statistically significant (P<0.05). (V) The differences in the endometrial classification and subendometrial blood flow classification between the two groups were statistically significant (P<0.05). CONCLUSIONS: Ultrasonographic endometrial blood flow classification, spiral artery blood flow parameters, and uterine artery blood flow parameters can be effective indexes for evaluating endometrial receptivity, and they have a certain clinical significance in evaluating the pregnancy outcome of RIF patients after retransplantation.
format Online
Article
Text
id pubmed-7475420
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher AME Publishing Company
record_format MEDLINE/PubMed
spelling pubmed-74754202020-09-17 Analysis of the guidance value of 3D ultrasound in evaluating endometrial receptivity for frozen-thawed embryo transfer in patients with repeated implantation failure Tong, Ruiqing Zhou, Ying He, Qi Zhuang, Yanyan Zhou, Weiqin Xia, Fei Ann Transl Med Original Article BACKGROUND: Repeated implantation failure (RIF) is currently believed by some scholars to be mainly related to the poor endometrial receptivity. Three-dimensional (3D) ultrasound, as a noninvasive examination, has attracted the most attention. This paper further discusses whether 3D ultrasound of the endometrial receptivity index has guidance value in the evaluation of pregnancy outcomes in patients with RIF following frozen-thawed embryo transfer. METHODS: A total of 79 patients with RIF were retrospectively analyzed. These 79 patients which were confirmed by the transvaginal ultrasonography detection comprised 36 cases of intrauterine pregnancy, which were included in the pregnancy group, and 43 cases with biochemical pregnancy (the HCG in blood or urine is only transient and can be detected by clinical biochemical methods. The pregnancy sac cannot be seen under ultrasound) or negative results of human chorionic gonadotropin (HCG) examination, which were included in the non-pregnancy group. The endometrial thickness, uterine volume, sub-endometrial blood flow type, pulsatility index (PI) and resistance index (RI) of the spiral artery; the RI and PI of the uterine artery; and the peak systolic velocity/end diastolic velocity (S/D) of the two groups were measured and analyzed. RESULTS: (I) There were no significant differences in the age, infertility years, body mass index (BMI), anti-Müllerian hormone (AMH), endometrial thickness on the hCG injection day, estradiol (E2), and progesterone (P) between the pregnant and non-pregnant groups (P>0.05). (II) There were no significant differences in the endometrial thickness, uterine volume, and RI and PI of the uterine artery on the day before the implantation between the two groups (P>0.05). (III) There was statistical difference in the sum of the S/D of the two uterine arteries between the two groups (P<0.05) with a cutoff value of 14.47 (P<0.05). (IV) The RI and PI of the spiral artery in the non-pregnancy group were lower than those in the pregnancy group, and the difference was statistically significant (P<0.05). (V) The differences in the endometrial classification and subendometrial blood flow classification between the two groups were statistically significant (P<0.05). CONCLUSIONS: Ultrasonographic endometrial blood flow classification, spiral artery blood flow parameters, and uterine artery blood flow parameters can be effective indexes for evaluating endometrial receptivity, and they have a certain clinical significance in evaluating the pregnancy outcome of RIF patients after retransplantation. AME Publishing Company 2020-08 /pmc/articles/PMC7475420/ /pubmed/32953744 http://dx.doi.org/10.21037/atm-20-5463 Text en 2020 Annals of Translational Medicine. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) .
spellingShingle Original Article
Tong, Ruiqing
Zhou, Ying
He, Qi
Zhuang, Yanyan
Zhou, Weiqin
Xia, Fei
Analysis of the guidance value of 3D ultrasound in evaluating endometrial receptivity for frozen-thawed embryo transfer in patients with repeated implantation failure
title Analysis of the guidance value of 3D ultrasound in evaluating endometrial receptivity for frozen-thawed embryo transfer in patients with repeated implantation failure
title_full Analysis of the guidance value of 3D ultrasound in evaluating endometrial receptivity for frozen-thawed embryo transfer in patients with repeated implantation failure
title_fullStr Analysis of the guidance value of 3D ultrasound in evaluating endometrial receptivity for frozen-thawed embryo transfer in patients with repeated implantation failure
title_full_unstemmed Analysis of the guidance value of 3D ultrasound in evaluating endometrial receptivity for frozen-thawed embryo transfer in patients with repeated implantation failure
title_short Analysis of the guidance value of 3D ultrasound in evaluating endometrial receptivity for frozen-thawed embryo transfer in patients with repeated implantation failure
title_sort analysis of the guidance value of 3d ultrasound in evaluating endometrial receptivity for frozen-thawed embryo transfer in patients with repeated implantation failure
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7475420/
https://www.ncbi.nlm.nih.gov/pubmed/32953744
http://dx.doi.org/10.21037/atm-20-5463
work_keys_str_mv AT tongruiqing analysisoftheguidancevalueof3dultrasoundinevaluatingendometrialreceptivityforfrozenthawedembryotransferinpatientswithrepeatedimplantationfailure
AT zhouying analysisoftheguidancevalueof3dultrasoundinevaluatingendometrialreceptivityforfrozenthawedembryotransferinpatientswithrepeatedimplantationfailure
AT heqi analysisoftheguidancevalueof3dultrasoundinevaluatingendometrialreceptivityforfrozenthawedembryotransferinpatientswithrepeatedimplantationfailure
AT zhuangyanyan analysisoftheguidancevalueof3dultrasoundinevaluatingendometrialreceptivityforfrozenthawedembryotransferinpatientswithrepeatedimplantationfailure
AT zhouweiqin analysisoftheguidancevalueof3dultrasoundinevaluatingendometrialreceptivityforfrozenthawedembryotransferinpatientswithrepeatedimplantationfailure
AT xiafei analysisoftheguidancevalueof3dultrasoundinevaluatingendometrialreceptivityforfrozenthawedembryotransferinpatientswithrepeatedimplantationfailure