Cargando…
Radiation doses in CT examinations from the West China Hospital, Sichuan University and setting local diagnostic references levels
BACKGROUND: Our study aims to summarize the data of radiation doses collected from consecutive CT examinations by using the Radiometrics software and contributing to the establishment of the region’s diagnostic reference levels (DRLs). METHODS: The radiation doses in 158,463 CT examinations performe...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
AME Publishing Company
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7475485/ https://www.ncbi.nlm.nih.gov/pubmed/32953810 http://dx.doi.org/10.21037/atm-20-5443 |
_version_ | 1783579516119023616 |
---|---|
author | Li, Zhenlin Zhang, Jinge Xia, Chunchao Zhao, Fei Zhang, Kai Li, Yuming Li, Lei Pu, Jin Peng, Wanlin Liu, Keling Guo, Yingkun |
author_facet | Li, Zhenlin Zhang, Jinge Xia, Chunchao Zhao, Fei Zhang, Kai Li, Yuming Li, Lei Pu, Jin Peng, Wanlin Liu, Keling Guo, Yingkun |
author_sort | Li, Zhenlin |
collection | PubMed |
description | BACKGROUND: Our study aims to summarize the data of radiation doses collected from consecutive CT examinations by using the Radiometrics software and contributing to the establishment of the region’s diagnostic reference levels (DRLs). METHODS: The radiation doses in 158,463 CT examinations performed on 106,275 adults between April 2017 and April 2019 were retrospectively analyzed. The median value and interquartile range (IQR) of volumetric CT dose index (CTDIvol), dose-length product (DLP), effective dose (ED), and size-specific dose estimate (SSDE) were calculated according to the scanning region. RESULTS: The median CTDIvol (mGy) for each scanning region was 42.3 (head), 6.2 (chest), and 9.0 (abdomen). The median DLPs (mGy.cm) for single-phase, multi-phase, and all examinations were as follows: 607, 794, and 641 for the head; 220, 393, and 237 for the chest; 298, 1,141, and 570 for the abdomen. The median EDs (mSv) for single-phase, multi-phase, and all examinations are as follows: 1.6, 2.6, and 1.8 for the head; 5.1, 8.1, and 5.3 for the chest; 5.8, 20.3, and 10.4 for the abdomen. CONCLUSIONS: Our study’s results could provide a basis for the evaluation of CT scanning radiation dosage and supply evidence for the establishment of local DRLs in China’s Sichuan Province. |
format | Online Article Text |
id | pubmed-7475485 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | AME Publishing Company |
record_format | MEDLINE/PubMed |
spelling | pubmed-74754852020-09-17 Radiation doses in CT examinations from the West China Hospital, Sichuan University and setting local diagnostic references levels Li, Zhenlin Zhang, Jinge Xia, Chunchao Zhao, Fei Zhang, Kai Li, Yuming Li, Lei Pu, Jin Peng, Wanlin Liu, Keling Guo, Yingkun Ann Transl Med Original Article BACKGROUND: Our study aims to summarize the data of radiation doses collected from consecutive CT examinations by using the Radiometrics software and contributing to the establishment of the region’s diagnostic reference levels (DRLs). METHODS: The radiation doses in 158,463 CT examinations performed on 106,275 adults between April 2017 and April 2019 were retrospectively analyzed. The median value and interquartile range (IQR) of volumetric CT dose index (CTDIvol), dose-length product (DLP), effective dose (ED), and size-specific dose estimate (SSDE) were calculated according to the scanning region. RESULTS: The median CTDIvol (mGy) for each scanning region was 42.3 (head), 6.2 (chest), and 9.0 (abdomen). The median DLPs (mGy.cm) for single-phase, multi-phase, and all examinations were as follows: 607, 794, and 641 for the head; 220, 393, and 237 for the chest; 298, 1,141, and 570 for the abdomen. The median EDs (mSv) for single-phase, multi-phase, and all examinations are as follows: 1.6, 2.6, and 1.8 for the head; 5.1, 8.1, and 5.3 for the chest; 5.8, 20.3, and 10.4 for the abdomen. CONCLUSIONS: Our study’s results could provide a basis for the evaluation of CT scanning radiation dosage and supply evidence for the establishment of local DRLs in China’s Sichuan Province. AME Publishing Company 2020-08 /pmc/articles/PMC7475485/ /pubmed/32953810 http://dx.doi.org/10.21037/atm-20-5443 Text en 2020 Annals of Translational Medicine. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) . |
spellingShingle | Original Article Li, Zhenlin Zhang, Jinge Xia, Chunchao Zhao, Fei Zhang, Kai Li, Yuming Li, Lei Pu, Jin Peng, Wanlin Liu, Keling Guo, Yingkun Radiation doses in CT examinations from the West China Hospital, Sichuan University and setting local diagnostic references levels |
title | Radiation doses in CT examinations from the West China Hospital, Sichuan University and setting local diagnostic references levels |
title_full | Radiation doses in CT examinations from the West China Hospital, Sichuan University and setting local diagnostic references levels |
title_fullStr | Radiation doses in CT examinations from the West China Hospital, Sichuan University and setting local diagnostic references levels |
title_full_unstemmed | Radiation doses in CT examinations from the West China Hospital, Sichuan University and setting local diagnostic references levels |
title_short | Radiation doses in CT examinations from the West China Hospital, Sichuan University and setting local diagnostic references levels |
title_sort | radiation doses in ct examinations from the west china hospital, sichuan university and setting local diagnostic references levels |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7475485/ https://www.ncbi.nlm.nih.gov/pubmed/32953810 http://dx.doi.org/10.21037/atm-20-5443 |
work_keys_str_mv | AT lizhenlin radiationdosesinctexaminationsfromthewestchinahospitalsichuanuniversityandsettinglocaldiagnosticreferenceslevels AT zhangjinge radiationdosesinctexaminationsfromthewestchinahospitalsichuanuniversityandsettinglocaldiagnosticreferenceslevels AT xiachunchao radiationdosesinctexaminationsfromthewestchinahospitalsichuanuniversityandsettinglocaldiagnosticreferenceslevels AT zhaofei radiationdosesinctexaminationsfromthewestchinahospitalsichuanuniversityandsettinglocaldiagnosticreferenceslevels AT zhangkai radiationdosesinctexaminationsfromthewestchinahospitalsichuanuniversityandsettinglocaldiagnosticreferenceslevels AT liyuming radiationdosesinctexaminationsfromthewestchinahospitalsichuanuniversityandsettinglocaldiagnosticreferenceslevels AT lilei radiationdosesinctexaminationsfromthewestchinahospitalsichuanuniversityandsettinglocaldiagnosticreferenceslevels AT pujin radiationdosesinctexaminationsfromthewestchinahospitalsichuanuniversityandsettinglocaldiagnosticreferenceslevels AT pengwanlin radiationdosesinctexaminationsfromthewestchinahospitalsichuanuniversityandsettinglocaldiagnosticreferenceslevels AT liukeling radiationdosesinctexaminationsfromthewestchinahospitalsichuanuniversityandsettinglocaldiagnosticreferenceslevels AT guoyingkun radiationdosesinctexaminationsfromthewestchinahospitalsichuanuniversityandsettinglocaldiagnosticreferenceslevels |