Cargando…

Total Knee Arthroplasty with Concomitant Corrective Tibial Osteotomy Using Patient-Specific Instrumentation and Computed Tomography–Based Navigation in Severe Post–High Tibial Osteotomy Valgus Collapse

We report the case of a 78-year-old woman with lateral knee osteoarthritis and severe valgus knee deformity after high tibial osteotomy. The patient's severe valgus tibial deformity with a valgus angle of 45° was evaluated using a 3-dimensional bone model, and a closing-wedge osteotomy was plan...

Descripción completa

Detalles Bibliográficos
Autores principales: Shibano, Koji, Kunugiza, Yasuo, Kawashima, Kunihiko, Tomita, Tetsuya
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7476213/
https://www.ncbi.nlm.nih.gov/pubmed/32923561
http://dx.doi.org/10.1016/j.artd.2020.07.029
_version_ 1783579662389084160
author Shibano, Koji
Kunugiza, Yasuo
Kawashima, Kunihiko
Tomita, Tetsuya
author_facet Shibano, Koji
Kunugiza, Yasuo
Kawashima, Kunihiko
Tomita, Tetsuya
author_sort Shibano, Koji
collection PubMed
description We report the case of a 78-year-old woman with lateral knee osteoarthritis and severe valgus knee deformity after high tibial osteotomy. The patient's severe valgus tibial deformity with a valgus angle of 45° was evaluated using a 3-dimensional bone model, and a closing-wedge osteotomy was planned. Combined total knee arthroplasty and closing-wedge tibial osteotomy were performed using patient-specific instrumentation and a computed tomography–based navigation system. A semiconstrained total knee system with a long stem was implanted for fixation of the osteotomy site in the tibia. The patient was able to walk without pain 2 years postoperatively. The Knee Society Score improved from 13 to 73 points, and the functional score improved from 30 to 65 points. This preoperative planning method and the treatment procedure would be beneficial for clinical decision-making and treatment of severe valgus knee deformities.
format Online
Article
Text
id pubmed-7476213
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-74762132020-09-11 Total Knee Arthroplasty with Concomitant Corrective Tibial Osteotomy Using Patient-Specific Instrumentation and Computed Tomography–Based Navigation in Severe Post–High Tibial Osteotomy Valgus Collapse Shibano, Koji Kunugiza, Yasuo Kawashima, Kunihiko Tomita, Tetsuya Arthroplast Today Case Report We report the case of a 78-year-old woman with lateral knee osteoarthritis and severe valgus knee deformity after high tibial osteotomy. The patient's severe valgus tibial deformity with a valgus angle of 45° was evaluated using a 3-dimensional bone model, and a closing-wedge osteotomy was planned. Combined total knee arthroplasty and closing-wedge tibial osteotomy were performed using patient-specific instrumentation and a computed tomography–based navigation system. A semiconstrained total knee system with a long stem was implanted for fixation of the osteotomy site in the tibia. The patient was able to walk without pain 2 years postoperatively. The Knee Society Score improved from 13 to 73 points, and the functional score improved from 30 to 65 points. This preoperative planning method and the treatment procedure would be beneficial for clinical decision-making and treatment of severe valgus knee deformities. Elsevier 2020-08-31 /pmc/articles/PMC7476213/ /pubmed/32923561 http://dx.doi.org/10.1016/j.artd.2020.07.029 Text en © 2020 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case Report
Shibano, Koji
Kunugiza, Yasuo
Kawashima, Kunihiko
Tomita, Tetsuya
Total Knee Arthroplasty with Concomitant Corrective Tibial Osteotomy Using Patient-Specific Instrumentation and Computed Tomography–Based Navigation in Severe Post–High Tibial Osteotomy Valgus Collapse
title Total Knee Arthroplasty with Concomitant Corrective Tibial Osteotomy Using Patient-Specific Instrumentation and Computed Tomography–Based Navigation in Severe Post–High Tibial Osteotomy Valgus Collapse
title_full Total Knee Arthroplasty with Concomitant Corrective Tibial Osteotomy Using Patient-Specific Instrumentation and Computed Tomography–Based Navigation in Severe Post–High Tibial Osteotomy Valgus Collapse
title_fullStr Total Knee Arthroplasty with Concomitant Corrective Tibial Osteotomy Using Patient-Specific Instrumentation and Computed Tomography–Based Navigation in Severe Post–High Tibial Osteotomy Valgus Collapse
title_full_unstemmed Total Knee Arthroplasty with Concomitant Corrective Tibial Osteotomy Using Patient-Specific Instrumentation and Computed Tomography–Based Navigation in Severe Post–High Tibial Osteotomy Valgus Collapse
title_short Total Knee Arthroplasty with Concomitant Corrective Tibial Osteotomy Using Patient-Specific Instrumentation and Computed Tomography–Based Navigation in Severe Post–High Tibial Osteotomy Valgus Collapse
title_sort total knee arthroplasty with concomitant corrective tibial osteotomy using patient-specific instrumentation and computed tomography–based navigation in severe post–high tibial osteotomy valgus collapse
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7476213/
https://www.ncbi.nlm.nih.gov/pubmed/32923561
http://dx.doi.org/10.1016/j.artd.2020.07.029
work_keys_str_mv AT shibanokoji totalkneearthroplastywithconcomitantcorrectivetibialosteotomyusingpatientspecificinstrumentationandcomputedtomographybasednavigationinsevereposthightibialosteotomyvalguscollapse
AT kunugizayasuo totalkneearthroplastywithconcomitantcorrectivetibialosteotomyusingpatientspecificinstrumentationandcomputedtomographybasednavigationinsevereposthightibialosteotomyvalguscollapse
AT kawashimakunihiko totalkneearthroplastywithconcomitantcorrectivetibialosteotomyusingpatientspecificinstrumentationandcomputedtomographybasednavigationinsevereposthightibialosteotomyvalguscollapse
AT tomitatetsuya totalkneearthroplastywithconcomitantcorrectivetibialosteotomyusingpatientspecificinstrumentationandcomputedtomographybasednavigationinsevereposthightibialosteotomyvalguscollapse