Cargando…

In vitro comparison of surgical techniques in times of the SARS-CoV-2 pandemic: electrocautery generates more droplets and aerosol than laser surgery or drilling

INTRODUCTION: Based on current knowledge, the SARS-CoV-2 is transmitted via droplet, aerosols and smear infection. Due to a confirmed high virus load in the upper respiratory tract of COVID-19 patients, there is a potential risk of infection for health care professionals when performing surgical pro...

Descripción completa

Detalles Bibliográficos
Autores principales: Guderian, Daniela B., Loth, Andreas G., Weiß, Roxanne, Diensthuber, Marc, Stöver, Timo, Leinung, Martin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7476645/
https://www.ncbi.nlm.nih.gov/pubmed/32895799
http://dx.doi.org/10.1007/s00405-020-06330-y
_version_ 1783579740625436672
author Guderian, Daniela B.
Loth, Andreas G.
Weiß, Roxanne
Diensthuber, Marc
Stöver, Timo
Leinung, Martin
author_facet Guderian, Daniela B.
Loth, Andreas G.
Weiß, Roxanne
Diensthuber, Marc
Stöver, Timo
Leinung, Martin
author_sort Guderian, Daniela B.
collection PubMed
description INTRODUCTION: Based on current knowledge, the SARS-CoV-2 is transmitted via droplet, aerosols and smear infection. Due to a confirmed high virus load in the upper respiratory tract of COVID-19 patients, there is a potential risk of infection for health care professionals when performing surgical procedures in this area. The aim of this study was the semi-quantitative comparison of ENT-typical interventions in the head and neck area with regard to particle and aerosol generation. These data can potentially contribute to a better risk assessment of aerogenic SARS-CoV-2-transmission caused by medical procedures. MATERIALS AND METHODS: As a model, a test chamber was created to examine various typical surgical interventions on porcine soft and hard tissues. Simultaneously, particle and aerosol release were recorded and semi-quantitatively evaluated time-dependently. Five typical surgical intervention techniques (mechanical stress with a passive instrument with and without suction, CO(2) laser treatment, drilling and bipolar electrocoagulation) were examined and compared regarding resulting particle release. RESULTS: Neither aerosols nor particles could be detected during mechanical manipulation with and without suction. The use of laser technique showed considerable formation of aerosol. During drilling, mainly solid tissue particles were scattered into the environment (18.2 ± 15.7 particles/cm(2)/min). The strongest particle release was determined during electrocoagulation (77.2 ± 30.4 particles/cm(2)/min). The difference in particle release between electrocoagulation and drilling was significant (p < 0.05), while particle diameter was comparable. In addition, relevant amounts of aerosol were released during electrocoagulation (79.6% of the maximum flue gas emission during laser treatment). DISCUSSION: Our results demonstrated clear differences comparing surgical model interventions. In contrast to sole mechanical stress with passive instruments, all active instruments (laser, drilling and electrocoagulation) released particles and aerosols. Assuming that particle and aerosol exposure is clinically correlated to the risk of SARS-CoV-2-transmission from the patient to the physician, a potential risk for health care professionals for infection cannot be excluded. Especially electrocautery is frequently used for emergency treatment, e.g., nose bleeding. The use of this technique may, therefore, be considered particularly critical in potentially infectious patients. Alternative methods may be given preference and personal protective equipment should be used consequently.
format Online
Article
Text
id pubmed-7476645
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-74766452020-09-08 In vitro comparison of surgical techniques in times of the SARS-CoV-2 pandemic: electrocautery generates more droplets and aerosol than laser surgery or drilling Guderian, Daniela B. Loth, Andreas G. Weiß, Roxanne Diensthuber, Marc Stöver, Timo Leinung, Martin Eur Arch Otorhinolaryngol Miscellaneous INTRODUCTION: Based on current knowledge, the SARS-CoV-2 is transmitted via droplet, aerosols and smear infection. Due to a confirmed high virus load in the upper respiratory tract of COVID-19 patients, there is a potential risk of infection for health care professionals when performing surgical procedures in this area. The aim of this study was the semi-quantitative comparison of ENT-typical interventions in the head and neck area with regard to particle and aerosol generation. These data can potentially contribute to a better risk assessment of aerogenic SARS-CoV-2-transmission caused by medical procedures. MATERIALS AND METHODS: As a model, a test chamber was created to examine various typical surgical interventions on porcine soft and hard tissues. Simultaneously, particle and aerosol release were recorded and semi-quantitatively evaluated time-dependently. Five typical surgical intervention techniques (mechanical stress with a passive instrument with and without suction, CO(2) laser treatment, drilling and bipolar electrocoagulation) were examined and compared regarding resulting particle release. RESULTS: Neither aerosols nor particles could be detected during mechanical manipulation with and without suction. The use of laser technique showed considerable formation of aerosol. During drilling, mainly solid tissue particles were scattered into the environment (18.2 ± 15.7 particles/cm(2)/min). The strongest particle release was determined during electrocoagulation (77.2 ± 30.4 particles/cm(2)/min). The difference in particle release between electrocoagulation and drilling was significant (p < 0.05), while particle diameter was comparable. In addition, relevant amounts of aerosol were released during electrocoagulation (79.6% of the maximum flue gas emission during laser treatment). DISCUSSION: Our results demonstrated clear differences comparing surgical model interventions. In contrast to sole mechanical stress with passive instruments, all active instruments (laser, drilling and electrocoagulation) released particles and aerosols. Assuming that particle and aerosol exposure is clinically correlated to the risk of SARS-CoV-2-transmission from the patient to the physician, a potential risk for health care professionals for infection cannot be excluded. Especially electrocautery is frequently used for emergency treatment, e.g., nose bleeding. The use of this technique may, therefore, be considered particularly critical in potentially infectious patients. Alternative methods may be given preference and personal protective equipment should be used consequently. Springer Berlin Heidelberg 2020-09-07 2021 /pmc/articles/PMC7476645/ /pubmed/32895799 http://dx.doi.org/10.1007/s00405-020-06330-y Text en © Springer-Verlag GmbH Germany, part of Springer Nature 2020 This article is made available via the PMC Open Access Subset for unrestricted research re-use and secondary analysis in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic.
spellingShingle Miscellaneous
Guderian, Daniela B.
Loth, Andreas G.
Weiß, Roxanne
Diensthuber, Marc
Stöver, Timo
Leinung, Martin
In vitro comparison of surgical techniques in times of the SARS-CoV-2 pandemic: electrocautery generates more droplets and aerosol than laser surgery or drilling
title In vitro comparison of surgical techniques in times of the SARS-CoV-2 pandemic: electrocautery generates more droplets and aerosol than laser surgery or drilling
title_full In vitro comparison of surgical techniques in times of the SARS-CoV-2 pandemic: electrocautery generates more droplets and aerosol than laser surgery or drilling
title_fullStr In vitro comparison of surgical techniques in times of the SARS-CoV-2 pandemic: electrocautery generates more droplets and aerosol than laser surgery or drilling
title_full_unstemmed In vitro comparison of surgical techniques in times of the SARS-CoV-2 pandemic: electrocautery generates more droplets and aerosol than laser surgery or drilling
title_short In vitro comparison of surgical techniques in times of the SARS-CoV-2 pandemic: electrocautery generates more droplets and aerosol than laser surgery or drilling
title_sort in vitro comparison of surgical techniques in times of the sars-cov-2 pandemic: electrocautery generates more droplets and aerosol than laser surgery or drilling
topic Miscellaneous
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7476645/
https://www.ncbi.nlm.nih.gov/pubmed/32895799
http://dx.doi.org/10.1007/s00405-020-06330-y
work_keys_str_mv AT guderiandanielab invitrocomparisonofsurgicaltechniquesintimesofthesarscov2pandemicelectrocauterygeneratesmoredropletsandaerosolthanlasersurgeryordrilling
AT lothandreasg invitrocomparisonofsurgicaltechniquesintimesofthesarscov2pandemicelectrocauterygeneratesmoredropletsandaerosolthanlasersurgeryordrilling
AT weißroxanne invitrocomparisonofsurgicaltechniquesintimesofthesarscov2pandemicelectrocauterygeneratesmoredropletsandaerosolthanlasersurgeryordrilling
AT diensthubermarc invitrocomparisonofsurgicaltechniquesintimesofthesarscov2pandemicelectrocauterygeneratesmoredropletsandaerosolthanlasersurgeryordrilling
AT stovertimo invitrocomparisonofsurgicaltechniquesintimesofthesarscov2pandemicelectrocauterygeneratesmoredropletsandaerosolthanlasersurgeryordrilling
AT leinungmartin invitrocomparisonofsurgicaltechniquesintimesofthesarscov2pandemicelectrocauterygeneratesmoredropletsandaerosolthanlasersurgeryordrilling