Cargando…

Robotic Retinal Surgery Impacts on Scleral Forces: In Vivo Study

PURPOSE: This study aims to map force interaction between instrument and sclera of in vivo rabbits during retinal procedures, and verify if a robotic active force control could prevent unwanted increase of forces on the sclera. METHODS: Experiments consisted in the performance of intraocular movemen...

Descripción completa

Detalles Bibliográficos
Autores principales: Urias, Müller G., Patel, Niravkumar, Ebrahimi, Ali, Iordachita, Iulian, Gehlbach, Peter L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7476674/
https://www.ncbi.nlm.nih.gov/pubmed/32953242
http://dx.doi.org/10.1167/tvst.9.10.2
_version_ 1783579746947301376
author Urias, Müller G.
Patel, Niravkumar
Ebrahimi, Ali
Iordachita, Iulian
Gehlbach, Peter L.
author_facet Urias, Müller G.
Patel, Niravkumar
Ebrahimi, Ali
Iordachita, Iulian
Gehlbach, Peter L.
author_sort Urias, Müller G.
collection PubMed
description PURPOSE: This study aims to map force interaction between instrument and sclera of in vivo rabbits during retinal procedures, and verify if a robotic active force control could prevent unwanted increase of forces on the sclera. METHODS: Experiments consisted in the performance of intraocular movements of a force sensing instrument, adjacent to the retinal surface, in radial directions, from the center to the periphery and back, and compared manual manipulations with robotic assistance and also robotic assistance with an active force control. This protocol was approved by the Animal Use and Ethical Committee and experiments were according to ARVO Statement of Animal Use. RESULTS: Mean forces using manual manipulations were 115 ± 51 mN. Using robotic assistance, mean forces were 118 ± 49 mN. Using an active force control method, overall mean forces reduced to 69 ± 15, with a statistical difference compared with other methods (P < 0.001). Comparing intraocular directions, superior sector required higher forces and the force control method reduced differences in forces between users and retained the same force pattern between them. CONCLUSIONS: Results validate that the introduction of robotic assistance might increase the dynamic interactions between instrument and sclera, and the addition of an active force control method reduces the forces at levels lower than manual manipulations. TRANSLATIONAL RELEVANCE: All marketing benefits from extreme accuracy and stability from robots, however, redundancy of safety mechanisms during intraocular manipulations, especially on force control and surgical awareness, would allow all utility of robotic assistance in ophthalmology.
format Online
Article
Text
id pubmed-7476674
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-74766742020-09-18 Robotic Retinal Surgery Impacts on Scleral Forces: In Vivo Study Urias, Müller G. Patel, Niravkumar Ebrahimi, Ali Iordachita, Iulian Gehlbach, Peter L. Transl Vis Sci Technol Article PURPOSE: This study aims to map force interaction between instrument and sclera of in vivo rabbits during retinal procedures, and verify if a robotic active force control could prevent unwanted increase of forces on the sclera. METHODS: Experiments consisted in the performance of intraocular movements of a force sensing instrument, adjacent to the retinal surface, in radial directions, from the center to the periphery and back, and compared manual manipulations with robotic assistance and also robotic assistance with an active force control. This protocol was approved by the Animal Use and Ethical Committee and experiments were according to ARVO Statement of Animal Use. RESULTS: Mean forces using manual manipulations were 115 ± 51 mN. Using robotic assistance, mean forces were 118 ± 49 mN. Using an active force control method, overall mean forces reduced to 69 ± 15, with a statistical difference compared with other methods (P < 0.001). Comparing intraocular directions, superior sector required higher forces and the force control method reduced differences in forces between users and retained the same force pattern between them. CONCLUSIONS: Results validate that the introduction of robotic assistance might increase the dynamic interactions between instrument and sclera, and the addition of an active force control method reduces the forces at levels lower than manual manipulations. TRANSLATIONAL RELEVANCE: All marketing benefits from extreme accuracy and stability from robots, however, redundancy of safety mechanisms during intraocular manipulations, especially on force control and surgical awareness, would allow all utility of robotic assistance in ophthalmology. The Association for Research in Vision and Ophthalmology 2020-09-01 /pmc/articles/PMC7476674/ /pubmed/32953242 http://dx.doi.org/10.1167/tvst.9.10.2 Text en Copyright 2020 The Authors http://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 International License.
spellingShingle Article
Urias, Müller G.
Patel, Niravkumar
Ebrahimi, Ali
Iordachita, Iulian
Gehlbach, Peter L.
Robotic Retinal Surgery Impacts on Scleral Forces: In Vivo Study
title Robotic Retinal Surgery Impacts on Scleral Forces: In Vivo Study
title_full Robotic Retinal Surgery Impacts on Scleral Forces: In Vivo Study
title_fullStr Robotic Retinal Surgery Impacts on Scleral Forces: In Vivo Study
title_full_unstemmed Robotic Retinal Surgery Impacts on Scleral Forces: In Vivo Study
title_short Robotic Retinal Surgery Impacts on Scleral Forces: In Vivo Study
title_sort robotic retinal surgery impacts on scleral forces: in vivo study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7476674/
https://www.ncbi.nlm.nih.gov/pubmed/32953242
http://dx.doi.org/10.1167/tvst.9.10.2
work_keys_str_mv AT uriasmullerg roboticretinalsurgeryimpactsonscleralforcesinvivostudy
AT patelniravkumar roboticretinalsurgeryimpactsonscleralforcesinvivostudy
AT ebrahimiali roboticretinalsurgeryimpactsonscleralforcesinvivostudy
AT iordachitaiulian roboticretinalsurgeryimpactsonscleralforcesinvivostudy
AT gehlbachpeterl roboticretinalsurgeryimpactsonscleralforcesinvivostudy