Treatment for a Metacarpal Shaft Fracture using Locked Wire Fixator: A Case Report of New Surgical Technique
INTRODUCTION: This article reports a case of metacarpal shaft fracture using a low-invasive simple locked wires fixator with a high degree of flexibility. A new surgical technique for this injury will also be presented. CASE REPORT: A 27-year-old female with the right 3rd metacarpal shaft fracture c...