Custom 3D Printed Jigs in Salvage Reverse Shoulder Arthroplasty for Failed Four-Part Proximal Humerus Fracture Fixation: A Case Report

INTRODUCTION: Complications of open reduction and internal fixation (ORIF) in four-part proximal humerus fractures (PHFs) include non-union, malunion, avascular necrosis of humeral head, and glenoid defect due to implant failure. Reverse total shoulder arthroplasty is a salvage procedure for cases o...

Descripción completa

Detalles Bibliográficos
Autores principales: Thati, Bharath, Bodanki, Chandrasekhar, Badam, Vamshi Kiran, Reddy, M V, Reddy, A V Gurava
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Indian Orthopaedic Research Group 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7476707/
https://www.ncbi.nlm.nih.gov/pubmed/32953650
http://dx.doi.org/10.13107/jocr.2020.v10.i02.1682
_version_ 1783579753852174336
author Thati, Bharath
Bodanki, Chandrasekhar
Badam, Vamshi Kiran
Reddy, M V
Reddy, A V Gurava
author_facet Thati, Bharath
Bodanki, Chandrasekhar
Badam, Vamshi Kiran
Reddy, M V
Reddy, A V Gurava
author_sort Thati, Bharath
collection PubMed
description INTRODUCTION: Complications of open reduction and internal fixation (ORIF) in four-part proximal humerus fractures (PHFs) include non-union, malunion, avascular necrosis of humeral head, and glenoid defect due to implant failure. Reverse total shoulder arthroplasty is a salvage procedure for cases of failed fixation. In cases with significant abnormal glenoid anatomy, custom-made patient-specific 3D printed jigs play a major role in pre-operative planning and accurate positioning of the glenoid component, thereby improving the final outcome. We report a case of salvage reverse shoulder arthroplasty done using the patient-specific custom-made 3D printed jig. CASE REPORT: A 58-year-old female sustained bilateral PHF due to electrocution and was treated with bilateral ORIF in single stage in February 2018.At 4 months from the time of surgery, the fracture on the left side had united, but there was non-union on the right side with screw penetration eroding the glenoid. Reverse shoulder arthroplasty was planned as a salvage procedure. Intraoperative, the glenoid was found to be small (2.7cm × 1.72cm) and there was a posterior glenoid defect due to screw penetration. During drilling for central peg, an iatrogenic glenoid fracture occurred. The procedure was deferred. After 4 months of conservative treatment, the glenoid fracture had united and then a definitive procedure with the reverse shoulder prosthesis was planned. 3D glenoid bone model was made based on the computed tomography scan and custom-made jigs are designed and 3D printed, which are specific for the patient. Reverse shoulder arthroplasty was done, and surgery went uneventful. The patient achieved active forward elevation of 110°, lateral elevation of 90°, and an external rotation of 10° at 1-year follow-up. CONCLUSION: Reverse shoulder arthroplasty can be considered as a salvage procedure for failed fixation of PHF with predictable outcomes. Custom-made patient-specific 3D printed jigs in reverse shoulder arthroplasty are useful in assessing the position and direction of central peg in case of small glenoid and glenoid bone defects. 3D bone models are useful in implant selection also.
format Online
Article
Text
id pubmed-7476707
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Indian Orthopaedic Research Group
record_format MEDLINE/PubMed
spelling pubmed-74767072020-09-18 Custom 3D Printed Jigs in Salvage Reverse Shoulder Arthroplasty for Failed Four-Part Proximal Humerus Fracture Fixation: A Case Report Thati, Bharath Bodanki, Chandrasekhar Badam, Vamshi Kiran Reddy, M V Reddy, A V Gurava J Orthop Case Rep Case Report INTRODUCTION: Complications of open reduction and internal fixation (ORIF) in four-part proximal humerus fractures (PHFs) include non-union, malunion, avascular necrosis of humeral head, and glenoid defect due to implant failure. Reverse total shoulder arthroplasty is a salvage procedure for cases of failed fixation. In cases with significant abnormal glenoid anatomy, custom-made patient-specific 3D printed jigs play a major role in pre-operative planning and accurate positioning of the glenoid component, thereby improving the final outcome. We report a case of salvage reverse shoulder arthroplasty done using the patient-specific custom-made 3D printed jig. CASE REPORT: A 58-year-old female sustained bilateral PHF due to electrocution and was treated with bilateral ORIF in single stage in February 2018.At 4 months from the time of surgery, the fracture on the left side had united, but there was non-union on the right side with screw penetration eroding the glenoid. Reverse shoulder arthroplasty was planned as a salvage procedure. Intraoperative, the glenoid was found to be small (2.7cm × 1.72cm) and there was a posterior glenoid defect due to screw penetration. During drilling for central peg, an iatrogenic glenoid fracture occurred. The procedure was deferred. After 4 months of conservative treatment, the glenoid fracture had united and then a definitive procedure with the reverse shoulder prosthesis was planned. 3D glenoid bone model was made based on the computed tomography scan and custom-made jigs are designed and 3D printed, which are specific for the patient. Reverse shoulder arthroplasty was done, and surgery went uneventful. The patient achieved active forward elevation of 110°, lateral elevation of 90°, and an external rotation of 10° at 1-year follow-up. CONCLUSION: Reverse shoulder arthroplasty can be considered as a salvage procedure for failed fixation of PHF with predictable outcomes. Custom-made patient-specific 3D printed jigs in reverse shoulder arthroplasty are useful in assessing the position and direction of central peg in case of small glenoid and glenoid bone defects. 3D bone models are useful in implant selection also. Indian Orthopaedic Research Group 2020 /pmc/articles/PMC7476707/ /pubmed/32953650 http://dx.doi.org/10.13107/jocr.2020.v10.i02.1682 Text en Copyright: © Indian Orthopaedic Research Group http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Thati, Bharath
Bodanki, Chandrasekhar
Badam, Vamshi Kiran
Reddy, M V
Reddy, A V Gurava
Custom 3D Printed Jigs in Salvage Reverse Shoulder Arthroplasty for Failed Four-Part Proximal Humerus Fracture Fixation: A Case Report
title Custom 3D Printed Jigs in Salvage Reverse Shoulder Arthroplasty for Failed Four-Part Proximal Humerus Fracture Fixation: A Case Report
title_full Custom 3D Printed Jigs in Salvage Reverse Shoulder Arthroplasty for Failed Four-Part Proximal Humerus Fracture Fixation: A Case Report
title_fullStr Custom 3D Printed Jigs in Salvage Reverse Shoulder Arthroplasty for Failed Four-Part Proximal Humerus Fracture Fixation: A Case Report
title_full_unstemmed Custom 3D Printed Jigs in Salvage Reverse Shoulder Arthroplasty for Failed Four-Part Proximal Humerus Fracture Fixation: A Case Report
title_short Custom 3D Printed Jigs in Salvage Reverse Shoulder Arthroplasty for Failed Four-Part Proximal Humerus Fracture Fixation: A Case Report
title_sort custom 3d printed jigs in salvage reverse shoulder arthroplasty for failed four-part proximal humerus fracture fixation: a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7476707/
https://www.ncbi.nlm.nih.gov/pubmed/32953650
http://dx.doi.org/10.13107/jocr.2020.v10.i02.1682
work_keys_str_mv AT thatibharath custom3dprintedjigsinsalvagereverseshoulderarthroplastyforfailedfourpartproximalhumerusfracturefixationacasereport
AT bodankichandrasekhar custom3dprintedjigsinsalvagereverseshoulderarthroplastyforfailedfourpartproximalhumerusfracturefixationacasereport
AT badamvamshikiran custom3dprintedjigsinsalvagereverseshoulderarthroplastyforfailedfourpartproximalhumerusfracturefixationacasereport
AT reddymv custom3dprintedjigsinsalvagereverseshoulderarthroplastyforfailedfourpartproximalhumerusfracturefixationacasereport
AT reddyavgurava custom3dprintedjigsinsalvagereverseshoulderarthroplastyforfailedfourpartproximalhumerusfracturefixationacasereport