Effectiveness of personal protective equipment in preventing severe acute respiratory syndrome coronavirus 2 infection among healthcare workers()

INTRODUCTION: Information on the effectiveness of personal protective equipment (PPE) for preventing severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection among healthcare workers (HCWs), especially among HCWs with frequent contact with patients with SARS-CoV-2, is limited. METHODS:...

Descripción completa

Detalles Bibliográficos
Autores principales: Suzuki, Tetsuya, Hayakawa, Kayoko, Ainai, Akira, Iwata-Yoshikawa, Naoko, Sano, Kaori, Nagata, Noriyo, Suzuki, Tadaki, Wakimoto, Yuji, Akiyama, Yutaro, Miyazato, Yusuke, Nakamura, Keiji, Ide, Satoshi, Nomoto, Hidetoshi, Nakamoto, Takato, Ota, Masayuki, Moriyama, Yuki, Sugiki, Yuko, Saito, Sho, Morioka, Shinichiro, Ishikane, Masahiro, Kinoshita, Noriko, Kutsuna, Satoshi, Ohmagari, Norio
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7480255/
https://www.ncbi.nlm.nih.gov/pubmed/32988731
http://dx.doi.org/10.1016/j.jiac.2020.09.006
Descripción
Sumario:INTRODUCTION: Information on the effectiveness of personal protective equipment (PPE) for preventing severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection among healthcare workers (HCWs), especially among HCWs with frequent contact with patients with SARS-CoV-2, is limited. METHODS: We conducted a prospective cohort study on 49 HCWs who worked in close contact with patients with SARS-CoV-2 infection. HCWs had blood samples taken every 2 weeks to test for SARS-CoV-2 antibodies using two different types of assay. RESULTS: Forty-nine participants (31 nurses, 15 doctors, 3 other workers) were enrolled. In total, 112 blood samples are obtained from participants. The median work days in 2 weeks was 9 (interquartile range (IQR): 5–10) days. In a single work day, 30 of the 49 participants (61.5%) had contact with patients with suspected or conformed SARS-CoV-2 at least 8 times, and approximately 60% of participants had more than 10 min of contact with a single patient. The median self-reported compliance to PPE was 90% (IQR: 80–100%). Seven participants tested positive for SARS-CoV-2 antibody using enzyme-linked immunosorbent assay (ELISA); however, none were seropositive for SARS-CoV-2 neutralizing antibody, so the positive ELISA results were assumed to be false-positive. CONCLUSIONS: The study provides evidence that appropriate PPE is sufficient to prevent infection amongHCWs. It is necessary to establish a system that provides a stable supply of PPE for HCWs to perform their duties.