Cargando…

Comparison of Two Commercially Available Immunoassays for the Measurement of Bovine Cardiac Troponin I in Cattle With Induced Myocardial Injury

Background: Multiple cardiac troponin I (cTnI) immunoassays are commercially available. Overall, assays have not been standardized, and inter-assay differences in the detection of the analyte cardiac troponin I can be clinically relevant. Objective: To compare the diagnostic accuracy of the commerci...

Descripción completa

Detalles Bibliográficos
Autores principales: Smith, Joe S., Varga, Anita, Schober, Karsten E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7481330/
https://www.ncbi.nlm.nih.gov/pubmed/33062647
http://dx.doi.org/10.3389/fvets.2020.00531
_version_ 1783580578359017472
author Smith, Joe S.
Varga, Anita
Schober, Karsten E.
author_facet Smith, Joe S.
Varga, Anita
Schober, Karsten E.
author_sort Smith, Joe S.
collection PubMed
description Background: Multiple cardiac troponin I (cTnI) immunoassays are commercially available. Overall, assays have not been standardized, and inter-assay differences in the detection of the analyte cardiac troponin I can be clinically relevant. Objective: To compare the diagnostic accuracy of the commercially available Abbott i-STAT®1 cTnI immunoassay (i-STAT) and the previously validated ADVIA Centaur TnI-Ultra immunoassay (Centaur) in cattle. Hypothesis: There will be significant differences in bovine serum cTnI results measured by the Centaur and i-STAT methods. Animals: Ten dairy cows with experimentally induced myocardial injury due to monensin administration. Thirty apparently healthy dairy cows with no history of monensin exposure served as controls. Methods: Blood was collected at various time points after administration of a single dose of monensin (20 to 50 mg/kg) via orogastric tube. A total of 112 blood samples were collected. Cardiac TnI concentration was analyzed with the two methods and the association between methods analyzed via linear regression. Bland-Altman analysis to evaluate agreement between methods was performed on samples divided into groups (cTnI < 1.0 ng/mL and cTnI ≥ 1.0 ng/mL). Results: Analyzer results were linearly correlated with each other (R(2) = 0.931). Samples with cTnI concentrations <1.0 ng/mL had a bias of −0.13 ± 0.20 ng/mL and samples with cTnI concentrations >1.0 ng/mL had a bias of −9.81 ± 13.26 ng/mL. Conclusions and clinical importance: The results of this study reveal that cTnI concentrations determined with the i-STAT are systematically lower compared to the concentrations determined by the Centaur.
format Online
Article
Text
id pubmed-7481330
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-74813302020-10-13 Comparison of Two Commercially Available Immunoassays for the Measurement of Bovine Cardiac Troponin I in Cattle With Induced Myocardial Injury Smith, Joe S. Varga, Anita Schober, Karsten E. Front Vet Sci Veterinary Science Background: Multiple cardiac troponin I (cTnI) immunoassays are commercially available. Overall, assays have not been standardized, and inter-assay differences in the detection of the analyte cardiac troponin I can be clinically relevant. Objective: To compare the diagnostic accuracy of the commercially available Abbott i-STAT®1 cTnI immunoassay (i-STAT) and the previously validated ADVIA Centaur TnI-Ultra immunoassay (Centaur) in cattle. Hypothesis: There will be significant differences in bovine serum cTnI results measured by the Centaur and i-STAT methods. Animals: Ten dairy cows with experimentally induced myocardial injury due to monensin administration. Thirty apparently healthy dairy cows with no history of monensin exposure served as controls. Methods: Blood was collected at various time points after administration of a single dose of monensin (20 to 50 mg/kg) via orogastric tube. A total of 112 blood samples were collected. Cardiac TnI concentration was analyzed with the two methods and the association between methods analyzed via linear regression. Bland-Altman analysis to evaluate agreement between methods was performed on samples divided into groups (cTnI < 1.0 ng/mL and cTnI ≥ 1.0 ng/mL). Results: Analyzer results were linearly correlated with each other (R(2) = 0.931). Samples with cTnI concentrations <1.0 ng/mL had a bias of −0.13 ± 0.20 ng/mL and samples with cTnI concentrations >1.0 ng/mL had a bias of −9.81 ± 13.26 ng/mL. Conclusions and clinical importance: The results of this study reveal that cTnI concentrations determined with the i-STAT are systematically lower compared to the concentrations determined by the Centaur. Frontiers Media S.A. 2020-08-27 /pmc/articles/PMC7481330/ /pubmed/33062647 http://dx.doi.org/10.3389/fvets.2020.00531 Text en Copyright © 2020 Smith, Varga and Schober. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Veterinary Science
Smith, Joe S.
Varga, Anita
Schober, Karsten E.
Comparison of Two Commercially Available Immunoassays for the Measurement of Bovine Cardiac Troponin I in Cattle With Induced Myocardial Injury
title Comparison of Two Commercially Available Immunoassays for the Measurement of Bovine Cardiac Troponin I in Cattle With Induced Myocardial Injury
title_full Comparison of Two Commercially Available Immunoassays for the Measurement of Bovine Cardiac Troponin I in Cattle With Induced Myocardial Injury
title_fullStr Comparison of Two Commercially Available Immunoassays for the Measurement of Bovine Cardiac Troponin I in Cattle With Induced Myocardial Injury
title_full_unstemmed Comparison of Two Commercially Available Immunoassays for the Measurement of Bovine Cardiac Troponin I in Cattle With Induced Myocardial Injury
title_short Comparison of Two Commercially Available Immunoassays for the Measurement of Bovine Cardiac Troponin I in Cattle With Induced Myocardial Injury
title_sort comparison of two commercially available immunoassays for the measurement of bovine cardiac troponin i in cattle with induced myocardial injury
topic Veterinary Science
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7481330/
https://www.ncbi.nlm.nih.gov/pubmed/33062647
http://dx.doi.org/10.3389/fvets.2020.00531
work_keys_str_mv AT smithjoes comparisonoftwocommerciallyavailableimmunoassaysforthemeasurementofbovinecardiactroponiniincattlewithinducedmyocardialinjury
AT vargaanita comparisonoftwocommerciallyavailableimmunoassaysforthemeasurementofbovinecardiactroponiniincattlewithinducedmyocardialinjury
AT schoberkarstene comparisonoftwocommerciallyavailableimmunoassaysforthemeasurementofbovinecardiactroponiniincattlewithinducedmyocardialinjury