The impact of frame numbers on cardiac ECG-gated SPECT images with interpolated extra frames using echocardiography

Background: Cardiac echocardiography and cardiac ECG-gated single-photon emission computed tomography (SPECT) are the most common modalities for left ventricle (LV) volumes and function assessment. The temporal resolution of SPECT images is limited and an ECG provides better temporal resolution. Thi...

Descripción completa

Detalles Bibliográficos
Autores principales: Sarebani, Maghsoud, Shiran, Mohammad Bagher, Bitarafan-Rajabi, Ahmad, Rastgou, Feridoon, Ojaghi Haghighi, Zahra, Abbasian Ardakani, Ali
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Iran University of Medical Sciences 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7481855/
https://www.ncbi.nlm.nih.gov/pubmed/32934946
http://dx.doi.org/10.34171/mjiri.34.57
_version_ 1783580694098739200
author Sarebani, Maghsoud
Shiran, Mohammad Bagher
Bitarafan-Rajabi, Ahmad
Rastgou, Feridoon
Ojaghi Haghighi, Zahra
Abbasian Ardakani, Ali
author_facet Sarebani, Maghsoud
Shiran, Mohammad Bagher
Bitarafan-Rajabi, Ahmad
Rastgou, Feridoon
Ojaghi Haghighi, Zahra
Abbasian Ardakani, Ali
author_sort Sarebani, Maghsoud
collection PubMed
description Background: Cardiac echocardiography and cardiac ECG-gated single-photon emission computed tomography (SPECT) are the most common modalities for left ventricle (LV) volumes and function assessment. The temporal resolution of SPECT images is limited and an ECG provides better temporal resolution. This study investigates the impact of frame numbers on images in terms of qualitative and quantitative assessments. Methods: In this study, 5 patients underwent echocardiography and cardiac ECG-gated SPECT imaging, and 5 standard views of the LV were recorded to determine LV walls boundaries and volumes. Also, 2 original images with 8 frames and 16 frames per cardiac cycle were recorded simultaneously in a single gantry orbit. Using the data extracted from the LV model, 8 extra new frames were created with interpolation between existing frames of the original 8-frame image. Three series of images (8 and 16 original and 16 interpolated) were reconstructed separately. LV volumes and ejection fraction (EF) were calculated using Quantitative Gated SPECT (QGS) software. Results: Compared to the original 8-frame gating, original 16-frame gated images resulted in larger end-diastole volume (EDV) (mean ± SD: 68.6 ± 27.11 mL vs 66.2±25.41 mL, p<0.001), smaller end-systole volume (ESV) (mean ± SD: 24.6±8.7 mL vs 26±7.3 mL, p<0.001), and higher EF (64% vs 60.2%, p<0.001). The results for the interpolated series were also different from the original images (closer to the original 16-frame series rather than 8-frame). Conclusion: Changing the frame number from 8 to 16 in cardiac ECG-gated SPECT images caused a significant change in LV volumes and EF. Frame interpolation with sophisticated algorithms can be used to improve the temporal resolution of SPECT images.
format Online
Article
Text
id pubmed-7481855
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Iran University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-74818552020-09-14 The impact of frame numbers on cardiac ECG-gated SPECT images with interpolated extra frames using echocardiography Sarebani, Maghsoud Shiran, Mohammad Bagher Bitarafan-Rajabi, Ahmad Rastgou, Feridoon Ojaghi Haghighi, Zahra Abbasian Ardakani, Ali Med J Islam Repub Iran Original Article Background: Cardiac echocardiography and cardiac ECG-gated single-photon emission computed tomography (SPECT) are the most common modalities for left ventricle (LV) volumes and function assessment. The temporal resolution of SPECT images is limited and an ECG provides better temporal resolution. This study investigates the impact of frame numbers on images in terms of qualitative and quantitative assessments. Methods: In this study, 5 patients underwent echocardiography and cardiac ECG-gated SPECT imaging, and 5 standard views of the LV were recorded to determine LV walls boundaries and volumes. Also, 2 original images with 8 frames and 16 frames per cardiac cycle were recorded simultaneously in a single gantry orbit. Using the data extracted from the LV model, 8 extra new frames were created with interpolation between existing frames of the original 8-frame image. Three series of images (8 and 16 original and 16 interpolated) were reconstructed separately. LV volumes and ejection fraction (EF) were calculated using Quantitative Gated SPECT (QGS) software. Results: Compared to the original 8-frame gating, original 16-frame gated images resulted in larger end-diastole volume (EDV) (mean ± SD: 68.6 ± 27.11 mL vs 66.2±25.41 mL, p<0.001), smaller end-systole volume (ESV) (mean ± SD: 24.6±8.7 mL vs 26±7.3 mL, p<0.001), and higher EF (64% vs 60.2%, p<0.001). The results for the interpolated series were also different from the original images (closer to the original 16-frame series rather than 8-frame). Conclusion: Changing the frame number from 8 to 16 in cardiac ECG-gated SPECT images caused a significant change in LV volumes and EF. Frame interpolation with sophisticated algorithms can be used to improve the temporal resolution of SPECT images. Iran University of Medical Sciences 2020-06-03 /pmc/articles/PMC7481855/ /pubmed/32934946 http://dx.doi.org/10.34171/mjiri.34.57 Text en © 2020 Iran University of Medical Sciences http://creativecommons.org/licenses/by-nc-sa/1.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution NonCommercial-ShareAlike 1.0 License (CC BY-NC-SA 1.0), which allows users to read, copy, distribute and make derivative works for non-commercial purposes from the material, as long as the author of the original work is cited properly.
spellingShingle Original Article
Sarebani, Maghsoud
Shiran, Mohammad Bagher
Bitarafan-Rajabi, Ahmad
Rastgou, Feridoon
Ojaghi Haghighi, Zahra
Abbasian Ardakani, Ali
The impact of frame numbers on cardiac ECG-gated SPECT images with interpolated extra frames using echocardiography
title The impact of frame numbers on cardiac ECG-gated SPECT images with interpolated extra frames using echocardiography
title_full The impact of frame numbers on cardiac ECG-gated SPECT images with interpolated extra frames using echocardiography
title_fullStr The impact of frame numbers on cardiac ECG-gated SPECT images with interpolated extra frames using echocardiography
title_full_unstemmed The impact of frame numbers on cardiac ECG-gated SPECT images with interpolated extra frames using echocardiography
title_short The impact of frame numbers on cardiac ECG-gated SPECT images with interpolated extra frames using echocardiography
title_sort impact of frame numbers on cardiac ecg-gated spect images with interpolated extra frames using echocardiography
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7481855/
https://www.ncbi.nlm.nih.gov/pubmed/32934946
http://dx.doi.org/10.34171/mjiri.34.57
work_keys_str_mv AT sarebanimaghsoud theimpactofframenumbersoncardiacecggatedspectimageswithinterpolatedextraframesusingechocardiography
AT shiranmohammadbagher theimpactofframenumbersoncardiacecggatedspectimageswithinterpolatedextraframesusingechocardiography
AT bitarafanrajabiahmad theimpactofframenumbersoncardiacecggatedspectimageswithinterpolatedextraframesusingechocardiography
AT rastgouferidoon theimpactofframenumbersoncardiacecggatedspectimageswithinterpolatedextraframesusingechocardiography
AT ojaghihaghighizahra theimpactofframenumbersoncardiacecggatedspectimageswithinterpolatedextraframesusingechocardiography
AT abbasianardakaniali theimpactofframenumbersoncardiacecggatedspectimageswithinterpolatedextraframesusingechocardiography
AT sarebanimaghsoud impactofframenumbersoncardiacecggatedspectimageswithinterpolatedextraframesusingechocardiography
AT shiranmohammadbagher impactofframenumbersoncardiacecggatedspectimageswithinterpolatedextraframesusingechocardiography
AT bitarafanrajabiahmad impactofframenumbersoncardiacecggatedspectimageswithinterpolatedextraframesusingechocardiography
AT rastgouferidoon impactofframenumbersoncardiacecggatedspectimageswithinterpolatedextraframesusingechocardiography
AT ojaghihaghighizahra impactofframenumbersoncardiacecggatedspectimageswithinterpolatedextraframesusingechocardiography
AT abbasianardakaniali impactofframenumbersoncardiacecggatedspectimageswithinterpolatedextraframesusingechocardiography