Cargando…

Hybrid volumetric-modulated arc therapy for postoperative breast cancer including regional lymph nodes: the advantage of dosimetric data and safety of toxicities

To improve the homogeneity and conformity of the irradiation dose for postoperative breast cancer including regional lymph nodes, we planned Hybrid volumetric-modulated arc therapy (VMAT), which combines conventional tangential field mainly for the chest area and VMAT mainly for the supraclavicular...

Descripción completa

Detalles Bibliográficos
Autores principales: Doi, Yoshiko, Nakao, Minoru, Miura, Hideharu, Ozawa, Shuichi, Kenjo, Masahiro, Nagata, Yasushi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7482153/
https://www.ncbi.nlm.nih.gov/pubmed/32785596
http://dx.doi.org/10.1093/jrr/rraa057
_version_ 1783580744205991936
author Doi, Yoshiko
Nakao, Minoru
Miura, Hideharu
Ozawa, Shuichi
Kenjo, Masahiro
Nagata, Yasushi
author_facet Doi, Yoshiko
Nakao, Minoru
Miura, Hideharu
Ozawa, Shuichi
Kenjo, Masahiro
Nagata, Yasushi
author_sort Doi, Yoshiko
collection PubMed
description To improve the homogeneity and conformity of the irradiation dose for postoperative breast cancer including regional lymph nodes, we planned Hybrid volumetric-modulated arc therapy (VMAT), which combines conventional tangential field mainly for the chest area and VMAT mainly for the supraclavicular area and marginal zone. In this study, we compared the dosimetric impact between traditional 3D conformal radiotherapy (3DCRT) and Hybrid VMAT and observed toxicities following Hybrid VMAT. A total of 70 patients indicated between October 2016 and December 2017 were included. The prescribed dose was 50 Gy/25 fractions. For the dosimetric impact, 3DCRT and Hybrid VMAT plans were compared in each patient with respect to the dosimetric parameters. Toxicities were followed using the Common Terminology Criteria for Adverse Events version 4.0. The median follow-up duration was 319 days. For the dosimetric impact, the homogeneity index (HI) and conformity index (CI) of PTV were significantly improved in the Hybrid VMAT plan compared with that in the 3DCRT plan (HI, 0.15 ± 0.07 in Hybrid VMAT vs 0.41 ± 0.19 in 3DCRT, P < 0.001; CI, 1.61 ± 0.44 in Hybrid VMAT vs 2.10 ± 0.56 in 3DCRT, P < 0.001). The mean irradiated ipsilateral lung dose was not significantly different in both plans (12.0 ± 2.4 Gy in Hybrid VMAT vs 11.8 ± 2.8 Gy in 3DCRT, P < 0.533). Regarding toxicity, there were no patients who developed ≥grade 3 acute toxicity and ≥grade 2 pneumonitis during the follow-up. Hybrid VMAT for postoperative breast cancer including regional lymph nodes was a reasonable technique that improved the homogeneity and conformity of the irradiation dose to the planning target volume while keeping the irradiation dose to organs at risk to a minimum.
format Online
Article
Text
id pubmed-7482153
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-74821532020-09-14 Hybrid volumetric-modulated arc therapy for postoperative breast cancer including regional lymph nodes: the advantage of dosimetric data and safety of toxicities Doi, Yoshiko Nakao, Minoru Miura, Hideharu Ozawa, Shuichi Kenjo, Masahiro Nagata, Yasushi J Radiat Res Regular Paper To improve the homogeneity and conformity of the irradiation dose for postoperative breast cancer including regional lymph nodes, we planned Hybrid volumetric-modulated arc therapy (VMAT), which combines conventional tangential field mainly for the chest area and VMAT mainly for the supraclavicular area and marginal zone. In this study, we compared the dosimetric impact between traditional 3D conformal radiotherapy (3DCRT) and Hybrid VMAT and observed toxicities following Hybrid VMAT. A total of 70 patients indicated between October 2016 and December 2017 were included. The prescribed dose was 50 Gy/25 fractions. For the dosimetric impact, 3DCRT and Hybrid VMAT plans were compared in each patient with respect to the dosimetric parameters. Toxicities were followed using the Common Terminology Criteria for Adverse Events version 4.0. The median follow-up duration was 319 days. For the dosimetric impact, the homogeneity index (HI) and conformity index (CI) of PTV were significantly improved in the Hybrid VMAT plan compared with that in the 3DCRT plan (HI, 0.15 ± 0.07 in Hybrid VMAT vs 0.41 ± 0.19 in 3DCRT, P < 0.001; CI, 1.61 ± 0.44 in Hybrid VMAT vs 2.10 ± 0.56 in 3DCRT, P < 0.001). The mean irradiated ipsilateral lung dose was not significantly different in both plans (12.0 ± 2.4 Gy in Hybrid VMAT vs 11.8 ± 2.8 Gy in 3DCRT, P < 0.533). Regarding toxicity, there were no patients who developed ≥grade 3 acute toxicity and ≥grade 2 pneumonitis during the follow-up. Hybrid VMAT for postoperative breast cancer including regional lymph nodes was a reasonable technique that improved the homogeneity and conformity of the irradiation dose to the planning target volume while keeping the irradiation dose to organs at risk to a minimum. Oxford University Press 2020-08-12 /pmc/articles/PMC7482153/ /pubmed/32785596 http://dx.doi.org/10.1093/jrr/rraa057 Text en © The Author(s) 2020. Published by Oxford University Press on behalf of The Japanese Radiation Research Society and Japanese Society for Radiation Oncology. http://creativecommons.org/licenses/by/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Regular Paper
Doi, Yoshiko
Nakao, Minoru
Miura, Hideharu
Ozawa, Shuichi
Kenjo, Masahiro
Nagata, Yasushi
Hybrid volumetric-modulated arc therapy for postoperative breast cancer including regional lymph nodes: the advantage of dosimetric data and safety of toxicities
title Hybrid volumetric-modulated arc therapy for postoperative breast cancer including regional lymph nodes: the advantage of dosimetric data and safety of toxicities
title_full Hybrid volumetric-modulated arc therapy for postoperative breast cancer including regional lymph nodes: the advantage of dosimetric data and safety of toxicities
title_fullStr Hybrid volumetric-modulated arc therapy for postoperative breast cancer including regional lymph nodes: the advantage of dosimetric data and safety of toxicities
title_full_unstemmed Hybrid volumetric-modulated arc therapy for postoperative breast cancer including regional lymph nodes: the advantage of dosimetric data and safety of toxicities
title_short Hybrid volumetric-modulated arc therapy for postoperative breast cancer including regional lymph nodes: the advantage of dosimetric data and safety of toxicities
title_sort hybrid volumetric-modulated arc therapy for postoperative breast cancer including regional lymph nodes: the advantage of dosimetric data and safety of toxicities
topic Regular Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7482153/
https://www.ncbi.nlm.nih.gov/pubmed/32785596
http://dx.doi.org/10.1093/jrr/rraa057
work_keys_str_mv AT doiyoshiko hybridvolumetricmodulatedarctherapyforpostoperativebreastcancerincludingregionallymphnodestheadvantageofdosimetricdataandsafetyoftoxicities
AT nakaominoru hybridvolumetricmodulatedarctherapyforpostoperativebreastcancerincludingregionallymphnodestheadvantageofdosimetricdataandsafetyoftoxicities
AT miurahideharu hybridvolumetricmodulatedarctherapyforpostoperativebreastcancerincludingregionallymphnodestheadvantageofdosimetricdataandsafetyoftoxicities
AT ozawashuichi hybridvolumetricmodulatedarctherapyforpostoperativebreastcancerincludingregionallymphnodestheadvantageofdosimetricdataandsafetyoftoxicities
AT kenjomasahiro hybridvolumetricmodulatedarctherapyforpostoperativebreastcancerincludingregionallymphnodestheadvantageofdosimetricdataandsafetyoftoxicities
AT nagatayasushi hybridvolumetricmodulatedarctherapyforpostoperativebreastcancerincludingregionallymphnodestheadvantageofdosimetricdataandsafetyoftoxicities