Serum Creatinine Electrochemical Biosensor on Printed Electrodes Using Monoenzymatic Pathway to 1-Methylhydantoin Detection

[Image: see text] The rising prevalence of Chronic Kidney Disease (CKD) has necessitated efforts towards the development of cost-effective and accurate biosensors for serum creatinine, which is a potent biomarker reflecting kidney function. This work presents a novel and cost-effective technique to...

Descripción completa

Detalles Bibliográficos
Autores principales: Dasgupta, Pallavi, Kumar, Vinay, Krishnaswamy, Patnam R., Bhat, Navakanta
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Chemical Society 2020
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7482293/
https://www.ncbi.nlm.nih.gov/pubmed/32923804
http://dx.doi.org/10.1021/acsomega.0c02997
_version_ 1783580762917830656
author Dasgupta, Pallavi
Kumar, Vinay
Krishnaswamy, Patnam R.
Bhat, Navakanta
author_facet Dasgupta, Pallavi
Kumar, Vinay
Krishnaswamy, Patnam R.
Bhat, Navakanta
author_sort Dasgupta, Pallavi
collection PubMed
description [Image: see text] The rising prevalence of Chronic Kidney Disease (CKD) has necessitated efforts towards the development of cost-effective and accurate biosensors for serum creatinine, which is a potent biomarker reflecting kidney function. This work presents a novel and cost-effective technique to estimate serum creatinine without any sample preprocessing. The technique involves the conversion of creatinine by a monoenzymatic pathway to 1-methylhydantoin. The concentration of 1-methylhydantoin is then quantified by utilizing its innate ability to form a complex with transition metals such as cobalt. The complex formation has been validated using optical spectroscopy and the transmittance at 290 nm wavelength is used to identify the optimum concentration of cobalt chloride in sensing chemistry. This chemical assay is shown to be robust against interference from serum albumin, the abundant plasma protein that can potentially influence the sensor response. The electrochemical biosensor developed using screen-printed electrodes thus provides highly selective creatinine estimation over the range of 0.2–4 mg/dL in a sample volume of 300 μL with no preprocessing and hence can be easily translated into a viable point-of-care (POC) device.
format Online
Article
Text
id pubmed-7482293
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher American Chemical Society
record_format MEDLINE/PubMed
spelling pubmed-74822932020-09-11 Serum Creatinine Electrochemical Biosensor on Printed Electrodes Using Monoenzymatic Pathway to 1-Methylhydantoin Detection Dasgupta, Pallavi Kumar, Vinay Krishnaswamy, Patnam R. Bhat, Navakanta ACS Omega [Image: see text] The rising prevalence of Chronic Kidney Disease (CKD) has necessitated efforts towards the development of cost-effective and accurate biosensors for serum creatinine, which is a potent biomarker reflecting kidney function. This work presents a novel and cost-effective technique to estimate serum creatinine without any sample preprocessing. The technique involves the conversion of creatinine by a monoenzymatic pathway to 1-methylhydantoin. The concentration of 1-methylhydantoin is then quantified by utilizing its innate ability to form a complex with transition metals such as cobalt. The complex formation has been validated using optical spectroscopy and the transmittance at 290 nm wavelength is used to identify the optimum concentration of cobalt chloride in sensing chemistry. This chemical assay is shown to be robust against interference from serum albumin, the abundant plasma protein that can potentially influence the sensor response. The electrochemical biosensor developed using screen-printed electrodes thus provides highly selective creatinine estimation over the range of 0.2–4 mg/dL in a sample volume of 300 μL with no preprocessing and hence can be easily translated into a viable point-of-care (POC) device. American Chemical Society 2020-08-27 /pmc/articles/PMC7482293/ /pubmed/32923804 http://dx.doi.org/10.1021/acsomega.0c02997 Text en Copyright © 2020 American Chemical Society This is an open access article published under an ACS AuthorChoice License (http://pubs.acs.org/page/policy/authorchoice_termsofuse.html) , which permits copying and redistribution of the article or any adaptations for non-commercial purposes.
spellingShingle Dasgupta, Pallavi
Kumar, Vinay
Krishnaswamy, Patnam R.
Bhat, Navakanta
Serum Creatinine Electrochemical Biosensor on Printed Electrodes Using Monoenzymatic Pathway to 1-Methylhydantoin Detection
title Serum Creatinine Electrochemical Biosensor on Printed Electrodes Using Monoenzymatic Pathway to 1-Methylhydantoin Detection
title_full Serum Creatinine Electrochemical Biosensor on Printed Electrodes Using Monoenzymatic Pathway to 1-Methylhydantoin Detection
title_fullStr Serum Creatinine Electrochemical Biosensor on Printed Electrodes Using Monoenzymatic Pathway to 1-Methylhydantoin Detection
title_full_unstemmed Serum Creatinine Electrochemical Biosensor on Printed Electrodes Using Monoenzymatic Pathway to 1-Methylhydantoin Detection
title_short Serum Creatinine Electrochemical Biosensor on Printed Electrodes Using Monoenzymatic Pathway to 1-Methylhydantoin Detection
title_sort serum creatinine electrochemical biosensor on printed electrodes using monoenzymatic pathway to 1-methylhydantoin detection
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7482293/
https://www.ncbi.nlm.nih.gov/pubmed/32923804
http://dx.doi.org/10.1021/acsomega.0c02997
work_keys_str_mv AT dasguptapallavi serumcreatinineelectrochemicalbiosensoronprintedelectrodesusingmonoenzymaticpathwayto1methylhydantoindetection
AT kumarvinay serumcreatinineelectrochemicalbiosensoronprintedelectrodesusingmonoenzymaticpathwayto1methylhydantoindetection
AT krishnaswamypatnamr serumcreatinineelectrochemicalbiosensoronprintedelectrodesusingmonoenzymaticpathwayto1methylhydantoindetection
AT bhatnavakanta serumcreatinineelectrochemicalbiosensoronprintedelectrodesusingmonoenzymaticpathwayto1methylhydantoindetection