Cargando…
Surface‐guided tomotherapy improves positioning and reduces treatment time: A retrospective analysis of 16 835 treatment fractions
PURPOSE: In this study, we have quantified the setup deviation and time gain when using fast surface scanning for daily setup/positioning with weekly megavoltage computed tomography (MVCT) and compared it to daily MVCT. METHODS: A total of 16 835 treatment fractions were analyzed, treated, and posit...
Autores principales: | Haraldsson, André, Ceberg, Sofie, Ceberg, Crister, Bäck, Sven, Engelholm, Silke, Engström, Per E. |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7484821/ https://www.ncbi.nlm.nih.gov/pubmed/32592288 http://dx.doi.org/10.1002/acm2.12936 |
Ejemplares similares
-
A Helical tomotherapy as a robust low‐dose treatment alternative for total skin irradiation
por: Haraldsson, André, et al.
Publicado: (2019) -
Evaluation of single-fraction high dose FLASH radiotherapy in a cohort of canine oral cancer patients
por: Børresen, Betina, et al.
Publicado: (2023) -
Surface guided radiotherapy (SGRT) improves breast cancer patient setup accuracy
por: Kügele, Malin, et al.
Publicado: (2019) -
Dosimetric effects of intrafractional isocenter variation during deep inspiration breath‐hold for breast cancer patients using surface‐guided radiotherapy
por: Kügele, Malin, et al.
Publicado: (2017) -
MR-PROTECT: Clinical feasibility of a prostate MRI-only radiotherapy treatment workflow and investigation of acceptance criteria
por: Persson, Emilia, et al.
Publicado: (2020)