Evaluation of the PTW microDiamond in edge‐on orientation for dosimetry in small fields
PURPOSE: The PTW microDiamond has an enhanced spatial resolution when operated in an edge‐on orientation but is not typically utilized in this orientation due to the specifications of the IAEA TRS‐483 code of practice for small field dosimetry. In this work the suitability of an edge‐on orientation...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7484886/ https://www.ncbi.nlm.nih.gov/pubmed/32441884 http://dx.doi.org/10.1002/acm2.12906 |
_version_ | 1783581064740995072 |
---|---|
author | Brace, Owen J. Alhujaili, Sultan F. Paino, Jason R. Butler, Duncan J. Wilkinson, Dean Oborn, Brad M. Rosenfeld, Anatoly B. Lerch, Michael L. F. Petasecca, Marco Davis, Jeremy A. |
author_facet | Brace, Owen J. Alhujaili, Sultan F. Paino, Jason R. Butler, Duncan J. Wilkinson, Dean Oborn, Brad M. Rosenfeld, Anatoly B. Lerch, Michael L. F. Petasecca, Marco Davis, Jeremy A. |
author_sort | Brace, Owen J. |
collection | PubMed |
description | PURPOSE: The PTW microDiamond has an enhanced spatial resolution when operated in an edge‐on orientation but is not typically utilized in this orientation due to the specifications of the IAEA TRS‐483 code of practice for small field dosimetry. In this work the suitability of an edge‐on orientation and advantages over the recommended face‐on orientation will be presented. METHODS: The PTW microDiamond in both orientations was compared on a Varian TrueBeam linac for: machine output factor (OF), percentage depth dose (PDD), and beam profile measurements from 10 × 10 cm(2) to a 0.5 × 0.5 cm(2) field size for 6X and 6FFF beam energies in a water tank. A quantification of the stem effect was performed in edge‐on orientation along with tissue to phantom ratio (TPR) measurements. An extensive angular dependence study for the two orientations was also undertaken within two custom PMMA plastic cylindrical phantoms. RESULTS: The OF of the PTW microDiamond in both orientations agrees within 1% down to the 2 × 2 cm(2) field size. The edge‐on orientation overresponds in the build‐up region but provides improved penumbra and has a maximum observed stem effect of 1%. In the edge‐on orientation there is an angular independent response with a maximum of 2% variation down to a 2 × 2 cm(2) field. The PTW microDiamond in edge‐on orientation for TPR measurements agreed to the CC01 ionization chamber within 1% for all field sizes. CONCLUSIONS: The microDiamond was shown to be suitable for small field dosimetry when operated in edge‐on orientation. When edge‐on, a significantly reduced angular dependence is observed with no significant stem effect, making it a more versatile QA instrument for rotational delivery techniques. |
format | Online Article Text |
id | pubmed-7484886 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-74848862020-09-18 Evaluation of the PTW microDiamond in edge‐on orientation for dosimetry in small fields Brace, Owen J. Alhujaili, Sultan F. Paino, Jason R. Butler, Duncan J. Wilkinson, Dean Oborn, Brad M. Rosenfeld, Anatoly B. Lerch, Michael L. F. Petasecca, Marco Davis, Jeremy A. J Appl Clin Med Phys Radiation Measurements PURPOSE: The PTW microDiamond has an enhanced spatial resolution when operated in an edge‐on orientation but is not typically utilized in this orientation due to the specifications of the IAEA TRS‐483 code of practice for small field dosimetry. In this work the suitability of an edge‐on orientation and advantages over the recommended face‐on orientation will be presented. METHODS: The PTW microDiamond in both orientations was compared on a Varian TrueBeam linac for: machine output factor (OF), percentage depth dose (PDD), and beam profile measurements from 10 × 10 cm(2) to a 0.5 × 0.5 cm(2) field size for 6X and 6FFF beam energies in a water tank. A quantification of the stem effect was performed in edge‐on orientation along with tissue to phantom ratio (TPR) measurements. An extensive angular dependence study for the two orientations was also undertaken within two custom PMMA plastic cylindrical phantoms. RESULTS: The OF of the PTW microDiamond in both orientations agrees within 1% down to the 2 × 2 cm(2) field size. The edge‐on orientation overresponds in the build‐up region but provides improved penumbra and has a maximum observed stem effect of 1%. In the edge‐on orientation there is an angular independent response with a maximum of 2% variation down to a 2 × 2 cm(2) field. The PTW microDiamond in edge‐on orientation for TPR measurements agreed to the CC01 ionization chamber within 1% for all field sizes. CONCLUSIONS: The microDiamond was shown to be suitable for small field dosimetry when operated in edge‐on orientation. When edge‐on, a significantly reduced angular dependence is observed with no significant stem effect, making it a more versatile QA instrument for rotational delivery techniques. John Wiley and Sons Inc. 2020-05-22 /pmc/articles/PMC7484886/ /pubmed/32441884 http://dx.doi.org/10.1002/acm2.12906 Text en © 2020 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Radiation Measurements Brace, Owen J. Alhujaili, Sultan F. Paino, Jason R. Butler, Duncan J. Wilkinson, Dean Oborn, Brad M. Rosenfeld, Anatoly B. Lerch, Michael L. F. Petasecca, Marco Davis, Jeremy A. Evaluation of the PTW microDiamond in edge‐on orientation for dosimetry in small fields |
title | Evaluation of the PTW microDiamond in edge‐on orientation for dosimetry in small fields |
title_full | Evaluation of the PTW microDiamond in edge‐on orientation for dosimetry in small fields |
title_fullStr | Evaluation of the PTW microDiamond in edge‐on orientation for dosimetry in small fields |
title_full_unstemmed | Evaluation of the PTW microDiamond in edge‐on orientation for dosimetry in small fields |
title_short | Evaluation of the PTW microDiamond in edge‐on orientation for dosimetry in small fields |
title_sort | evaluation of the ptw microdiamond in edge‐on orientation for dosimetry in small fields |
topic | Radiation Measurements |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7484886/ https://www.ncbi.nlm.nih.gov/pubmed/32441884 http://dx.doi.org/10.1002/acm2.12906 |
work_keys_str_mv | AT braceowenj evaluationoftheptwmicrodiamondinedgeonorientationfordosimetryinsmallfields AT alhujailisultanf evaluationoftheptwmicrodiamondinedgeonorientationfordosimetryinsmallfields AT painojasonr evaluationoftheptwmicrodiamondinedgeonorientationfordosimetryinsmallfields AT butlerduncanj evaluationoftheptwmicrodiamondinedgeonorientationfordosimetryinsmallfields AT wilkinsondean evaluationoftheptwmicrodiamondinedgeonorientationfordosimetryinsmallfields AT obornbradm evaluationoftheptwmicrodiamondinedgeonorientationfordosimetryinsmallfields AT rosenfeldanatolyb evaluationoftheptwmicrodiamondinedgeonorientationfordosimetryinsmallfields AT lerchmichaellf evaluationoftheptwmicrodiamondinedgeonorientationfordosimetryinsmallfields AT petaseccamarco evaluationoftheptwmicrodiamondinedgeonorientationfordosimetryinsmallfields AT davisjeremya evaluationoftheptwmicrodiamondinedgeonorientationfordosimetryinsmallfields |