Cargando…
Development of a stereoscopic CT metal artifact management algorithm using gantry angle tilts for head and neck patients
Dental amalgams are a common source of artifacts in head and neck (HN) images. Commercial artifact reduction techniques have been offered, but are substantially ineffectual at reducing artifacts from dental amalgams, can produce additional artifacts, provide inaccurate HU information, or require ext...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7484887/ https://www.ncbi.nlm.nih.gov/pubmed/32506820 http://dx.doi.org/10.1002/acm2.12922 |
_version_ | 1783581064983216128 |
---|---|
author | Branco, Daniela Kry, Stephen Taylor, Paige Rong, John Zhang, Xiaodong Peterson, Christine Frank, Steven Followill, David |
author_facet | Branco, Daniela Kry, Stephen Taylor, Paige Rong, John Zhang, Xiaodong Peterson, Christine Frank, Steven Followill, David |
author_sort | Branco, Daniela |
collection | PubMed |
description | Dental amalgams are a common source of artifacts in head and neck (HN) images. Commercial artifact reduction techniques have been offered, but are substantially ineffectual at reducing artifacts from dental amalgams, can produce additional artifacts, provide inaccurate HU information, or require extensive computation time, and thus offer limited clinically utility. The goal of this work was to define and validate a novel algorithm and provide a phantom‐based testing as proof of principle. An initial clinical comparison to a vendor's current solution was also performed. The algorithm uses two‐angled CT scans in order to generate a single image set with minimal artifacts posterior to the metal implants. The algorithm was evaluated using a phantom simulating a HN patient with dental fillings. Baseline (no artifacts) geometrical measurements of the phantom were taken in the anterior–posterior, left–right, and superior–inferior directions and compared to the metal‐corrected images using our algorithm to evaluate possible distortion from application of the algorithm. Mean HU numbers were also compared between the baseline scan and corrected image sets. A similar analysis was performed on the vendor's algorithm for comparison. The algorithm developed in this work successfully preserved the image geometry and HU and corrected the CT metal artifacts in the region posterior to the metal. The average total distortion for all gantry angles in the AP, LR, and SI directions was 0.17, 0.12, and 0.14 mm, respectively. The HU measurements showed significant consistency throughout the different reconstructed images when compared to the baseline image sets. The vendor's algorithm also showed no geometrical distortion but performed inferiorly in the HU number analysis compared to our technique. Our novel metal artifact management algorithm, using CT gantry angle tilts, provides a promising technique for clinical management of metal artifacts from dental amalgam. |
format | Online Article Text |
id | pubmed-7484887 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-74848872020-09-18 Development of a stereoscopic CT metal artifact management algorithm using gantry angle tilts for head and neck patients Branco, Daniela Kry, Stephen Taylor, Paige Rong, John Zhang, Xiaodong Peterson, Christine Frank, Steven Followill, David J Appl Clin Med Phys Radiation Oncology Physics Dental amalgams are a common source of artifacts in head and neck (HN) images. Commercial artifact reduction techniques have been offered, but are substantially ineffectual at reducing artifacts from dental amalgams, can produce additional artifacts, provide inaccurate HU information, or require extensive computation time, and thus offer limited clinically utility. The goal of this work was to define and validate a novel algorithm and provide a phantom‐based testing as proof of principle. An initial clinical comparison to a vendor's current solution was also performed. The algorithm uses two‐angled CT scans in order to generate a single image set with minimal artifacts posterior to the metal implants. The algorithm was evaluated using a phantom simulating a HN patient with dental fillings. Baseline (no artifacts) geometrical measurements of the phantom were taken in the anterior–posterior, left–right, and superior–inferior directions and compared to the metal‐corrected images using our algorithm to evaluate possible distortion from application of the algorithm. Mean HU numbers were also compared between the baseline scan and corrected image sets. A similar analysis was performed on the vendor's algorithm for comparison. The algorithm developed in this work successfully preserved the image geometry and HU and corrected the CT metal artifacts in the region posterior to the metal. The average total distortion for all gantry angles in the AP, LR, and SI directions was 0.17, 0.12, and 0.14 mm, respectively. The HU measurements showed significant consistency throughout the different reconstructed images when compared to the baseline image sets. The vendor's algorithm also showed no geometrical distortion but performed inferiorly in the HU number analysis compared to our technique. Our novel metal artifact management algorithm, using CT gantry angle tilts, provides a promising technique for clinical management of metal artifacts from dental amalgam. John Wiley and Sons Inc. 2020-06-07 /pmc/articles/PMC7484887/ /pubmed/32506820 http://dx.doi.org/10.1002/acm2.12922 Text en © 2020 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Radiation Oncology Physics Branco, Daniela Kry, Stephen Taylor, Paige Rong, John Zhang, Xiaodong Peterson, Christine Frank, Steven Followill, David Development of a stereoscopic CT metal artifact management algorithm using gantry angle tilts for head and neck patients |
title | Development of a stereoscopic CT metal artifact management algorithm using gantry angle tilts for head and neck patients |
title_full | Development of a stereoscopic CT metal artifact management algorithm using gantry angle tilts for head and neck patients |
title_fullStr | Development of a stereoscopic CT metal artifact management algorithm using gantry angle tilts for head and neck patients |
title_full_unstemmed | Development of a stereoscopic CT metal artifact management algorithm using gantry angle tilts for head and neck patients |
title_short | Development of a stereoscopic CT metal artifact management algorithm using gantry angle tilts for head and neck patients |
title_sort | development of a stereoscopic ct metal artifact management algorithm using gantry angle tilts for head and neck patients |
topic | Radiation Oncology Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7484887/ https://www.ncbi.nlm.nih.gov/pubmed/32506820 http://dx.doi.org/10.1002/acm2.12922 |
work_keys_str_mv | AT brancodaniela developmentofastereoscopicctmetalartifactmanagementalgorithmusinggantryangletiltsforheadandneckpatients AT krystephen developmentofastereoscopicctmetalartifactmanagementalgorithmusinggantryangletiltsforheadandneckpatients AT taylorpaige developmentofastereoscopicctmetalartifactmanagementalgorithmusinggantryangletiltsforheadandneckpatients AT rongjohn developmentofastereoscopicctmetalartifactmanagementalgorithmusinggantryangletiltsforheadandneckpatients AT zhangxiaodong developmentofastereoscopicctmetalartifactmanagementalgorithmusinggantryangletiltsforheadandneckpatients AT petersonchristine developmentofastereoscopicctmetalartifactmanagementalgorithmusinggantryangletiltsforheadandneckpatients AT franksteven developmentofastereoscopicctmetalartifactmanagementalgorithmusinggantryangletiltsforheadandneckpatients AT followilldavid developmentofastereoscopicctmetalartifactmanagementalgorithmusinggantryangletiltsforheadandneckpatients |