Cargando…

A synthetic biosensor to detect peroxisomal acetyl-CoA concentration for compartmentalized metabolic engineering

BACKGROUND: Sub-cellular compartmentalization is used by cells to create favorable microenvironments for various metabolic reactions. These compartments concentrate enzymes, separate competing metabolic reactions, and isolate toxic intermediates. Such advantages have been recently harnessed by metab...

Descripción completa

Detalles Bibliográficos
Autores principales: Huttanus, Herbert M., Senger, Ryan S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: PeerJ Inc. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7485502/
https://www.ncbi.nlm.nih.gov/pubmed/33194349
http://dx.doi.org/10.7717/peerj.9805
_version_ 1783581163113152512
author Huttanus, Herbert M.
Senger, Ryan S.
author_facet Huttanus, Herbert M.
Senger, Ryan S.
author_sort Huttanus, Herbert M.
collection PubMed
description BACKGROUND: Sub-cellular compartmentalization is used by cells to create favorable microenvironments for various metabolic reactions. These compartments concentrate enzymes, separate competing metabolic reactions, and isolate toxic intermediates. Such advantages have been recently harnessed by metabolic engineers to improve the production of various high-value chemicals via compartmentalized metabolic engineering. However, measuring sub-cellular concentrations of key metabolites represents a grand challenge for compartmentalized metabolic engineering. METHODS: To this end, we developed a synthetic biosensor to measure a key metabolite, acetyl-CoA, in a representative compartment of yeast, the peroxisome. This synthetic biosensor uses enzyme re-localization via PTS1 signal peptides to construct a metabolic pathway in the peroxisome which converts acetyl-CoA to polyhydroxybutyrate (PHB) via three enzymes. The PHB is then quantified by HPLC. RESULTS: The biosensor demonstrated the difference in relative peroxisomal acetyl-CoA availability under various culture conditions and was also applied to screening a library of single knockout yeast mutants. The screening identified several mutants with drastically reduced peroxisomal acetyl-CoA and one with potentially increased levels. We expect our synthetic biosensors can be widely used to investigate sub-cellular metabolism and facilitate the “design-build-test” cycle of compartmentalized metabolic engineering.
format Online
Article
Text
id pubmed-7485502
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher PeerJ Inc.
record_format MEDLINE/PubMed
spelling pubmed-74855022020-11-12 A synthetic biosensor to detect peroxisomal acetyl-CoA concentration for compartmentalized metabolic engineering Huttanus, Herbert M. Senger, Ryan S. PeerJ Biotechnology BACKGROUND: Sub-cellular compartmentalization is used by cells to create favorable microenvironments for various metabolic reactions. These compartments concentrate enzymes, separate competing metabolic reactions, and isolate toxic intermediates. Such advantages have been recently harnessed by metabolic engineers to improve the production of various high-value chemicals via compartmentalized metabolic engineering. However, measuring sub-cellular concentrations of key metabolites represents a grand challenge for compartmentalized metabolic engineering. METHODS: To this end, we developed a synthetic biosensor to measure a key metabolite, acetyl-CoA, in a representative compartment of yeast, the peroxisome. This synthetic biosensor uses enzyme re-localization via PTS1 signal peptides to construct a metabolic pathway in the peroxisome which converts acetyl-CoA to polyhydroxybutyrate (PHB) via three enzymes. The PHB is then quantified by HPLC. RESULTS: The biosensor demonstrated the difference in relative peroxisomal acetyl-CoA availability under various culture conditions and was also applied to screening a library of single knockout yeast mutants. The screening identified several mutants with drastically reduced peroxisomal acetyl-CoA and one with potentially increased levels. We expect our synthetic biosensors can be widely used to investigate sub-cellular metabolism and facilitate the “design-build-test” cycle of compartmentalized metabolic engineering. PeerJ Inc. 2020-09-08 /pmc/articles/PMC7485502/ /pubmed/33194349 http://dx.doi.org/10.7717/peerj.9805 Text en ©2020 Huttanus and Senger https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, reproduction and adaptation in any medium and for any purpose provided that it is properly attributed. For attribution, the original author(s), title, publication source (PeerJ) and either DOI or URL of the article must be cited.
spellingShingle Biotechnology
Huttanus, Herbert M.
Senger, Ryan S.
A synthetic biosensor to detect peroxisomal acetyl-CoA concentration for compartmentalized metabolic engineering
title A synthetic biosensor to detect peroxisomal acetyl-CoA concentration for compartmentalized metabolic engineering
title_full A synthetic biosensor to detect peroxisomal acetyl-CoA concentration for compartmentalized metabolic engineering
title_fullStr A synthetic biosensor to detect peroxisomal acetyl-CoA concentration for compartmentalized metabolic engineering
title_full_unstemmed A synthetic biosensor to detect peroxisomal acetyl-CoA concentration for compartmentalized metabolic engineering
title_short A synthetic biosensor to detect peroxisomal acetyl-CoA concentration for compartmentalized metabolic engineering
title_sort synthetic biosensor to detect peroxisomal acetyl-coa concentration for compartmentalized metabolic engineering
topic Biotechnology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7485502/
https://www.ncbi.nlm.nih.gov/pubmed/33194349
http://dx.doi.org/10.7717/peerj.9805
work_keys_str_mv AT huttanusherbertm asyntheticbiosensortodetectperoxisomalacetylcoaconcentrationforcompartmentalizedmetabolicengineering
AT sengerryans asyntheticbiosensortodetectperoxisomalacetylcoaconcentrationforcompartmentalizedmetabolicengineering
AT huttanusherbertm syntheticbiosensortodetectperoxisomalacetylcoaconcentrationforcompartmentalizedmetabolicengineering
AT sengerryans syntheticbiosensortodetectperoxisomalacetylcoaconcentrationforcompartmentalizedmetabolicengineering