Cargando…

Caesarean delivery rates and analgesia effectiveness following injections of sterile water for back pain in labour: A multicentre, randomised placebo controlled trial

BACKGROUND: About a third of women experience severe back pain during labour. Injecting small volumes of intracutaneous sterile water into the lumbar region can be used to relieve this pain, however the procedure is controversial and previous reviews call for high quality trials to establish efficac...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Nigel, Gao, Yu, Collins, Sally L., Mårtensson, Lena B., Randall, Wendy, Rowe, Toni-Marie, Kildea, Sue
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7486301/
https://www.ncbi.nlm.nih.gov/pubmed/32954233
http://dx.doi.org/10.1016/j.eclinm.2020.100447
_version_ 1783581310847025152
author Lee, Nigel
Gao, Yu
Collins, Sally L.
Mårtensson, Lena B.
Randall, Wendy
Rowe, Toni-Marie
Kildea, Sue
author_facet Lee, Nigel
Gao, Yu
Collins, Sally L.
Mårtensson, Lena B.
Randall, Wendy
Rowe, Toni-Marie
Kildea, Sue
author_sort Lee, Nigel
collection PubMed
description BACKGROUND: About a third of women experience severe back pain during labour. Injecting small volumes of intracutaneous sterile water into the lumbar region can be used to relieve this pain, however the procedure is controversial and previous reviews call for high quality trials to establish efficacy. We evaluated the impact on birth outcomes and analgesic effects of sterile water injections. METHODS: A multicentre, double-blind trial undertaken between December 2012 and December 2017 in one British and 15 Australian maternity units. Women experiencing severe back-pain in labour were assigned (1:1) by an independently generated randomisation schedule stratified by site to injections of either sterile water or saline placebo. Participants and caregivers were blinded to group allocation. The primary outcome was caesarean delivery rate. Main secondary outcomes included at least 30% or 50% reduction in self-reported pain scores at 30, 60 and 90 minutes after treatment. Intention to treat analysis were used and the level of significance for the multiple clinical outcomes was set at p<0.001 with the Bonferroni correction applied. The study is registered with the ACTRN Registry number, ACTRN1261100022195 FINDINGS: Between December 9, 2012, and December 15, 2017, 1166 women were recruited and randomised: 587 women received sterile water injections (SWI) and 579 a saline placebo. Seven women in the SWI group and 12 in the placebo group were excluded as consent was not completed, leaving 580 and 567, respectively, included in the analysis. The proportions of caesarean delivery were 17·1% (82 of 580) in the SWI group and 14·8% (82 of 567) in the placebo (RR 1·16, 95% CI 0·88–1.51; p = 0·293). At 30 min post treatment 60·8% (330 of 543) of women in the SWI group reported a 30% reduction in self-reported pain compared to 31·4% (163 of 520) placebo (RR 1·94, 95% CI 1·68–2·24; p=<0·001) and 43·3% (235 of 534) SWI reported a 50% reduction versus 18·1% (94 of 520) placebo (RR 2·39, 95% CI 1·95–2·94; p=<0·001). The analgesic effect of SWI compared to placebo remained significant at 60 and 90 min post-treatment. There were no significant differences in other maternal or neonatal outcomes. INTERPRETATION: Compared to placebo, injections of sterile water did not reduce rates of caesarean delivery. For the main secondary outcome of pain relief the intervention did result in significantly more women reporting at least 30% and 50% reduction in pain for up to 90 min. Water injections have no effect on birth outcomes though can be an effective treatment for the relief of labour-related back pain. Funded by the National Health and Medical Research Council.
format Online
Article
Text
id pubmed-7486301
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-74863012020-09-17 Caesarean delivery rates and analgesia effectiveness following injections of sterile water for back pain in labour: A multicentre, randomised placebo controlled trial Lee, Nigel Gao, Yu Collins, Sally L. Mårtensson, Lena B. Randall, Wendy Rowe, Toni-Marie Kildea, Sue EClinicalMedicine Research Paper BACKGROUND: About a third of women experience severe back pain during labour. Injecting small volumes of intracutaneous sterile water into the lumbar region can be used to relieve this pain, however the procedure is controversial and previous reviews call for high quality trials to establish efficacy. We evaluated the impact on birth outcomes and analgesic effects of sterile water injections. METHODS: A multicentre, double-blind trial undertaken between December 2012 and December 2017 in one British and 15 Australian maternity units. Women experiencing severe back-pain in labour were assigned (1:1) by an independently generated randomisation schedule stratified by site to injections of either sterile water or saline placebo. Participants and caregivers were blinded to group allocation. The primary outcome was caesarean delivery rate. Main secondary outcomes included at least 30% or 50% reduction in self-reported pain scores at 30, 60 and 90 minutes after treatment. Intention to treat analysis were used and the level of significance for the multiple clinical outcomes was set at p<0.001 with the Bonferroni correction applied. The study is registered with the ACTRN Registry number, ACTRN1261100022195 FINDINGS: Between December 9, 2012, and December 15, 2017, 1166 women were recruited and randomised: 587 women received sterile water injections (SWI) and 579 a saline placebo. Seven women in the SWI group and 12 in the placebo group were excluded as consent was not completed, leaving 580 and 567, respectively, included in the analysis. The proportions of caesarean delivery were 17·1% (82 of 580) in the SWI group and 14·8% (82 of 567) in the placebo (RR 1·16, 95% CI 0·88–1.51; p = 0·293). At 30 min post treatment 60·8% (330 of 543) of women in the SWI group reported a 30% reduction in self-reported pain compared to 31·4% (163 of 520) placebo (RR 1·94, 95% CI 1·68–2·24; p=<0·001) and 43·3% (235 of 534) SWI reported a 50% reduction versus 18·1% (94 of 520) placebo (RR 2·39, 95% CI 1·95–2·94; p=<0·001). The analgesic effect of SWI compared to placebo remained significant at 60 and 90 min post-treatment. There were no significant differences in other maternal or neonatal outcomes. INTERPRETATION: Compared to placebo, injections of sterile water did not reduce rates of caesarean delivery. For the main secondary outcome of pain relief the intervention did result in significantly more women reporting at least 30% and 50% reduction in pain for up to 90 min. Water injections have no effect on birth outcomes though can be an effective treatment for the relief of labour-related back pain. Funded by the National Health and Medical Research Council. Elsevier 2020-07-03 /pmc/articles/PMC7486301/ /pubmed/32954233 http://dx.doi.org/10.1016/j.eclinm.2020.100447 Text en © 2020 The Author(s) http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Research Paper
Lee, Nigel
Gao, Yu
Collins, Sally L.
Mårtensson, Lena B.
Randall, Wendy
Rowe, Toni-Marie
Kildea, Sue
Caesarean delivery rates and analgesia effectiveness following injections of sterile water for back pain in labour: A multicentre, randomised placebo controlled trial
title Caesarean delivery rates and analgesia effectiveness following injections of sterile water for back pain in labour: A multicentre, randomised placebo controlled trial
title_full Caesarean delivery rates and analgesia effectiveness following injections of sterile water for back pain in labour: A multicentre, randomised placebo controlled trial
title_fullStr Caesarean delivery rates and analgesia effectiveness following injections of sterile water for back pain in labour: A multicentre, randomised placebo controlled trial
title_full_unstemmed Caesarean delivery rates and analgesia effectiveness following injections of sterile water for back pain in labour: A multicentre, randomised placebo controlled trial
title_short Caesarean delivery rates and analgesia effectiveness following injections of sterile water for back pain in labour: A multicentre, randomised placebo controlled trial
title_sort caesarean delivery rates and analgesia effectiveness following injections of sterile water for back pain in labour: a multicentre, randomised placebo controlled trial
topic Research Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7486301/
https://www.ncbi.nlm.nih.gov/pubmed/32954233
http://dx.doi.org/10.1016/j.eclinm.2020.100447
work_keys_str_mv AT leenigel caesareandeliveryratesandanalgesiaeffectivenessfollowinginjectionsofsterilewaterforbackpaininlabouramulticentrerandomisedplacebocontrolledtrial
AT gaoyu caesareandeliveryratesandanalgesiaeffectivenessfollowinginjectionsofsterilewaterforbackpaininlabouramulticentrerandomisedplacebocontrolledtrial
AT collinssallyl caesareandeliveryratesandanalgesiaeffectivenessfollowinginjectionsofsterilewaterforbackpaininlabouramulticentrerandomisedplacebocontrolledtrial
AT martenssonlenab caesareandeliveryratesandanalgesiaeffectivenessfollowinginjectionsofsterilewaterforbackpaininlabouramulticentrerandomisedplacebocontrolledtrial
AT randallwendy caesareandeliveryratesandanalgesiaeffectivenessfollowinginjectionsofsterilewaterforbackpaininlabouramulticentrerandomisedplacebocontrolledtrial
AT rowetonimarie caesareandeliveryratesandanalgesiaeffectivenessfollowinginjectionsofsterilewaterforbackpaininlabouramulticentrerandomisedplacebocontrolledtrial
AT kildeasue caesareandeliveryratesandanalgesiaeffectivenessfollowinginjectionsofsterilewaterforbackpaininlabouramulticentrerandomisedplacebocontrolledtrial