Cargando…

Particle release from implantoplasty of dental implants and impact on cells

BACKGROUND: With increasing numbers of dental implants placed annually, complications such as peri-implantitis and the subsequent periprosthetic osteolysis are becoming a major concern. Implantoplasty, a commonly used treatment of peri-implantitis, aims to remove plaque from exposed implants and red...

Descripción completa

Detalles Bibliográficos
Autores principales: Barrak, Fadi N., Li, Siwei, Muntane, Albert M., Jones, Julian R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7486360/
https://www.ncbi.nlm.nih.gov/pubmed/32918144
http://dx.doi.org/10.1186/s40729-020-00247-1
_version_ 1783581318860242944
author Barrak, Fadi N.
Li, Siwei
Muntane, Albert M.
Jones, Julian R.
author_facet Barrak, Fadi N.
Li, Siwei
Muntane, Albert M.
Jones, Julian R.
author_sort Barrak, Fadi N.
collection PubMed
description BACKGROUND: With increasing numbers of dental implants placed annually, complications such as peri-implantitis and the subsequent periprosthetic osteolysis are becoming a major concern. Implantoplasty, a commonly used treatment of peri-implantitis, aims to remove plaque from exposed implants and reduce future microbial adhesion and colonisation by mechanically modifying the implant surface topography, delaying re-infection/colonisation of the site. This in vitro study aims to investigate the release of particles from dental implants and their effects on human gingival fibroblasts (HGFs), following an in vitro mock implantoplasty procedure with a diamond burr. MATERIALS AND METHODS: Commercially available implants made from grade 4 (commercially pure, CP) titanium (G4) and grade 5 Ti-6Al-4 V titanium (G5) alloy implants were investigated. Implant particle compositions were quantified by inductively coupled plasma optical emission spectrometer (ICP-OES) following acid digestion. HGFs were cultured in presence of implant particles, and viability was determined using a metabolic activity assay. RESULTS: Microparticles and nanoparticles were released from both G4 and G5 implants following the mock implantoplasty procedure. A small amount of vanadium ions were released from G5 particles following immersion in both simulated body fluid and cell culture medium, resulting in significantly reduced viability of HGFs after 10 days of culture. CONCLUSION: There is a need for careful evaluation of the materials used in dental implants and the potential risks of the individual constituents of any alloy. The potential cytotoxicity of G5 titanium alloy particles should be considered when choosing a device for dental implants. Additionally, regardless of implant material, the implantoplasty procedure can release nanometre-sized particles, the full systemic effect of which is not fully understood. As such, authors do not recommend implantoplasty for the treatment of peri-implantitis.
format Online
Article
Text
id pubmed-7486360
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-74863602020-09-21 Particle release from implantoplasty of dental implants and impact on cells Barrak, Fadi N. Li, Siwei Muntane, Albert M. Jones, Julian R. Int J Implant Dent Research BACKGROUND: With increasing numbers of dental implants placed annually, complications such as peri-implantitis and the subsequent periprosthetic osteolysis are becoming a major concern. Implantoplasty, a commonly used treatment of peri-implantitis, aims to remove plaque from exposed implants and reduce future microbial adhesion and colonisation by mechanically modifying the implant surface topography, delaying re-infection/colonisation of the site. This in vitro study aims to investigate the release of particles from dental implants and their effects on human gingival fibroblasts (HGFs), following an in vitro mock implantoplasty procedure with a diamond burr. MATERIALS AND METHODS: Commercially available implants made from grade 4 (commercially pure, CP) titanium (G4) and grade 5 Ti-6Al-4 V titanium (G5) alloy implants were investigated. Implant particle compositions were quantified by inductively coupled plasma optical emission spectrometer (ICP-OES) following acid digestion. HGFs were cultured in presence of implant particles, and viability was determined using a metabolic activity assay. RESULTS: Microparticles and nanoparticles were released from both G4 and G5 implants following the mock implantoplasty procedure. A small amount of vanadium ions were released from G5 particles following immersion in both simulated body fluid and cell culture medium, resulting in significantly reduced viability of HGFs after 10 days of culture. CONCLUSION: There is a need for careful evaluation of the materials used in dental implants and the potential risks of the individual constituents of any alloy. The potential cytotoxicity of G5 titanium alloy particles should be considered when choosing a device for dental implants. Additionally, regardless of implant material, the implantoplasty procedure can release nanometre-sized particles, the full systemic effect of which is not fully understood. As such, authors do not recommend implantoplasty for the treatment of peri-implantitis. Springer Berlin Heidelberg 2020-09-12 /pmc/articles/PMC7486360/ /pubmed/32918144 http://dx.doi.org/10.1186/s40729-020-00247-1 Text en © The Author(s) 2020 Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Research
Barrak, Fadi N.
Li, Siwei
Muntane, Albert M.
Jones, Julian R.
Particle release from implantoplasty of dental implants and impact on cells
title Particle release from implantoplasty of dental implants and impact on cells
title_full Particle release from implantoplasty of dental implants and impact on cells
title_fullStr Particle release from implantoplasty of dental implants and impact on cells
title_full_unstemmed Particle release from implantoplasty of dental implants and impact on cells
title_short Particle release from implantoplasty of dental implants and impact on cells
title_sort particle release from implantoplasty of dental implants and impact on cells
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7486360/
https://www.ncbi.nlm.nih.gov/pubmed/32918144
http://dx.doi.org/10.1186/s40729-020-00247-1
work_keys_str_mv AT barrakfadin particlereleasefromimplantoplastyofdentalimplantsandimpactoncells
AT lisiwei particlereleasefromimplantoplastyofdentalimplantsandimpactoncells
AT muntanealbertm particlereleasefromimplantoplastyofdentalimplantsandimpactoncells
AT jonesjulianr particlereleasefromimplantoplastyofdentalimplantsandimpactoncells