Artifact Rates for 2D Retinal Nerve Fiber Layer Thickness Versus 3D Neuroretinal Rim Thickness Using Spectral-Domain Optical Coherence Tomography

PURPOSE: To compare the rates of clinically significant artifacts for two-dimensional peripapillary retinal nerve fiber layer (RNFL) thickness versus three-dimensional (3D) neuroretinal rim thickness using spectral-domain optical coherence tomography (SD-OCT). METHODS: Only one eye per patient was u...

Descripción completa

Detalles Bibliográficos
Autores principales: Park, Elli A., Tsikata, Edem, Lee, Jenny Jyoung, Shieh, Eric, Braaf, Boy, Vakoc, Benjamin J., Bouma, Brett E., de Boer, Johannes F., Chen, Teresa C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7488619/
https://www.ncbi.nlm.nih.gov/pubmed/32974082
http://dx.doi.org/10.1167/tvst.9.10.10
_version_ 1783581729103020032
author Park, Elli A.
Tsikata, Edem
Lee, Jenny Jyoung
Shieh, Eric
Braaf, Boy
Vakoc, Benjamin J.
Bouma, Brett E.
de Boer, Johannes F.
Chen, Teresa C.
author_facet Park, Elli A.
Tsikata, Edem
Lee, Jenny Jyoung
Shieh, Eric
Braaf, Boy
Vakoc, Benjamin J.
Bouma, Brett E.
de Boer, Johannes F.
Chen, Teresa C.
author_sort Park, Elli A.
collection PubMed
description PURPOSE: To compare the rates of clinically significant artifacts for two-dimensional peripapillary retinal nerve fiber layer (RNFL) thickness versus three-dimensional (3D) neuroretinal rim thickness using spectral-domain optical coherence tomography (SD-OCT). METHODS: Only one eye per patient was used for analysis of 120 glaucoma patients and 114 normal patients. For RNFL scans and optic nerve scans, 15 artifact types were calculated per B-scan and per eye. Neuroretinal rim tissue was quantified by the minimum distance band (MDB). Global MDB neuroretinal rim thicknesses were calculated before and after manual deletion of B-scans with artifacts and subsequent automated interpolation. A clinically significant artifact was defined as one requiring manual correction or repeat scanning. RESULTS: Among glaucomatous eyes, artifact rates per B-scan were significantly more common in RNFL scans (61.7%, 74 of 120) compared to B-scans in neuroretinal rim volume scans (20.9%, 1423 of 6820) (95% confidence interval [CI], 31.6–50.0; P < 0.0001). For clinically significant artifact rates per eye, optic nerve scans had significantly fewer artifacts (15.8% of glaucomatous eyes, 13.2% of normal eyes) compared to RNFL scans (61.7% of glaucomatous eyes, 25.4% of normal eyes) (glaucoma group: 95% CI, 34.1–57.5, P < 0.0001; normal group: 95% CI, 1.3–23.3, P = 0.03). CONCLUSIONS: Compared to the most commonly used RNFL thickness scans, optic nerve volume scans less frequently require manual correction or repeat scanning to obtain accurate measurements. TRANSLATIONAL RELEVANCE: This paper illustrates the potential for 3D OCT algorithms to improve in vivo imaging in glaucoma.
format Online
Article
Text
id pubmed-7488619
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-74886192020-09-23 Artifact Rates for 2D Retinal Nerve Fiber Layer Thickness Versus 3D Neuroretinal Rim Thickness Using Spectral-Domain Optical Coherence Tomography Park, Elli A. Tsikata, Edem Lee, Jenny Jyoung Shieh, Eric Braaf, Boy Vakoc, Benjamin J. Bouma, Brett E. de Boer, Johannes F. Chen, Teresa C. Transl Vis Sci Technol Article PURPOSE: To compare the rates of clinically significant artifacts for two-dimensional peripapillary retinal nerve fiber layer (RNFL) thickness versus three-dimensional (3D) neuroretinal rim thickness using spectral-domain optical coherence tomography (SD-OCT). METHODS: Only one eye per patient was used for analysis of 120 glaucoma patients and 114 normal patients. For RNFL scans and optic nerve scans, 15 artifact types were calculated per B-scan and per eye. Neuroretinal rim tissue was quantified by the minimum distance band (MDB). Global MDB neuroretinal rim thicknesses were calculated before and after manual deletion of B-scans with artifacts and subsequent automated interpolation. A clinically significant artifact was defined as one requiring manual correction or repeat scanning. RESULTS: Among glaucomatous eyes, artifact rates per B-scan were significantly more common in RNFL scans (61.7%, 74 of 120) compared to B-scans in neuroretinal rim volume scans (20.9%, 1423 of 6820) (95% confidence interval [CI], 31.6–50.0; P < 0.0001). For clinically significant artifact rates per eye, optic nerve scans had significantly fewer artifacts (15.8% of glaucomatous eyes, 13.2% of normal eyes) compared to RNFL scans (61.7% of glaucomatous eyes, 25.4% of normal eyes) (glaucoma group: 95% CI, 34.1–57.5, P < 0.0001; normal group: 95% CI, 1.3–23.3, P = 0.03). CONCLUSIONS: Compared to the most commonly used RNFL thickness scans, optic nerve volume scans less frequently require manual correction or repeat scanning to obtain accurate measurements. TRANSLATIONAL RELEVANCE: This paper illustrates the potential for 3D OCT algorithms to improve in vivo imaging in glaucoma. The Association for Research in Vision and Ophthalmology 2020-09-10 /pmc/articles/PMC7488619/ /pubmed/32974082 http://dx.doi.org/10.1167/tvst.9.10.10 Text en Copyright 2020 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
spellingShingle Article
Park, Elli A.
Tsikata, Edem
Lee, Jenny Jyoung
Shieh, Eric
Braaf, Boy
Vakoc, Benjamin J.
Bouma, Brett E.
de Boer, Johannes F.
Chen, Teresa C.
Artifact Rates for 2D Retinal Nerve Fiber Layer Thickness Versus 3D Neuroretinal Rim Thickness Using Spectral-Domain Optical Coherence Tomography
title Artifact Rates for 2D Retinal Nerve Fiber Layer Thickness Versus 3D Neuroretinal Rim Thickness Using Spectral-Domain Optical Coherence Tomography
title_full Artifact Rates for 2D Retinal Nerve Fiber Layer Thickness Versus 3D Neuroretinal Rim Thickness Using Spectral-Domain Optical Coherence Tomography
title_fullStr Artifact Rates for 2D Retinal Nerve Fiber Layer Thickness Versus 3D Neuroretinal Rim Thickness Using Spectral-Domain Optical Coherence Tomography
title_full_unstemmed Artifact Rates for 2D Retinal Nerve Fiber Layer Thickness Versus 3D Neuroretinal Rim Thickness Using Spectral-Domain Optical Coherence Tomography
title_short Artifact Rates for 2D Retinal Nerve Fiber Layer Thickness Versus 3D Neuroretinal Rim Thickness Using Spectral-Domain Optical Coherence Tomography
title_sort artifact rates for 2d retinal nerve fiber layer thickness versus 3d neuroretinal rim thickness using spectral-domain optical coherence tomography
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7488619/
https://www.ncbi.nlm.nih.gov/pubmed/32974082
http://dx.doi.org/10.1167/tvst.9.10.10
work_keys_str_mv AT parkellia artifactratesfor2dretinalnervefiberlayerthicknessversus3dneuroretinalrimthicknessusingspectraldomainopticalcoherencetomography
AT tsikataedem artifactratesfor2dretinalnervefiberlayerthicknessversus3dneuroretinalrimthicknessusingspectraldomainopticalcoherencetomography
AT leejennyjyoung artifactratesfor2dretinalnervefiberlayerthicknessversus3dneuroretinalrimthicknessusingspectraldomainopticalcoherencetomography
AT shieheric artifactratesfor2dretinalnervefiberlayerthicknessversus3dneuroretinalrimthicknessusingspectraldomainopticalcoherencetomography
AT braafboy artifactratesfor2dretinalnervefiberlayerthicknessversus3dneuroretinalrimthicknessusingspectraldomainopticalcoherencetomography
AT vakocbenjaminj artifactratesfor2dretinalnervefiberlayerthicknessversus3dneuroretinalrimthicknessusingspectraldomainopticalcoherencetomography
AT boumabrette artifactratesfor2dretinalnervefiberlayerthicknessversus3dneuroretinalrimthicknessusingspectraldomainopticalcoherencetomography
AT deboerjohannesf artifactratesfor2dretinalnervefiberlayerthicknessversus3dneuroretinalrimthicknessusingspectraldomainopticalcoherencetomography
AT chenteresac artifactratesfor2dretinalnervefiberlayerthicknessversus3dneuroretinalrimthicknessusingspectraldomainopticalcoherencetomography