Cargando…
Artifact Rates for 2D Retinal Nerve Fiber Layer Thickness Versus 3D Neuroretinal Rim Thickness Using Spectral-Domain Optical Coherence Tomography
PURPOSE: To compare the rates of clinically significant artifacts for two-dimensional peripapillary retinal nerve fiber layer (RNFL) thickness versus three-dimensional (3D) neuroretinal rim thickness using spectral-domain optical coherence tomography (SD-OCT). METHODS: Only one eye per patient was u...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Association for Research in Vision and Ophthalmology
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7488619/ https://www.ncbi.nlm.nih.gov/pubmed/32974082 http://dx.doi.org/10.1167/tvst.9.10.10 |
_version_ | 1783581729103020032 |
---|---|
author | Park, Elli A. Tsikata, Edem Lee, Jenny Jyoung Shieh, Eric Braaf, Boy Vakoc, Benjamin J. Bouma, Brett E. de Boer, Johannes F. Chen, Teresa C. |
author_facet | Park, Elli A. Tsikata, Edem Lee, Jenny Jyoung Shieh, Eric Braaf, Boy Vakoc, Benjamin J. Bouma, Brett E. de Boer, Johannes F. Chen, Teresa C. |
author_sort | Park, Elli A. |
collection | PubMed |
description | PURPOSE: To compare the rates of clinically significant artifacts for two-dimensional peripapillary retinal nerve fiber layer (RNFL) thickness versus three-dimensional (3D) neuroretinal rim thickness using spectral-domain optical coherence tomography (SD-OCT). METHODS: Only one eye per patient was used for analysis of 120 glaucoma patients and 114 normal patients. For RNFL scans and optic nerve scans, 15 artifact types were calculated per B-scan and per eye. Neuroretinal rim tissue was quantified by the minimum distance band (MDB). Global MDB neuroretinal rim thicknesses were calculated before and after manual deletion of B-scans with artifacts and subsequent automated interpolation. A clinically significant artifact was defined as one requiring manual correction or repeat scanning. RESULTS: Among glaucomatous eyes, artifact rates per B-scan were significantly more common in RNFL scans (61.7%, 74 of 120) compared to B-scans in neuroretinal rim volume scans (20.9%, 1423 of 6820) (95% confidence interval [CI], 31.6–50.0; P < 0.0001). For clinically significant artifact rates per eye, optic nerve scans had significantly fewer artifacts (15.8% of glaucomatous eyes, 13.2% of normal eyes) compared to RNFL scans (61.7% of glaucomatous eyes, 25.4% of normal eyes) (glaucoma group: 95% CI, 34.1–57.5, P < 0.0001; normal group: 95% CI, 1.3–23.3, P = 0.03). CONCLUSIONS: Compared to the most commonly used RNFL thickness scans, optic nerve volume scans less frequently require manual correction or repeat scanning to obtain accurate measurements. TRANSLATIONAL RELEVANCE: This paper illustrates the potential for 3D OCT algorithms to improve in vivo imaging in glaucoma. |
format | Online Article Text |
id | pubmed-7488619 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | The Association for Research in Vision and Ophthalmology |
record_format | MEDLINE/PubMed |
spelling | pubmed-74886192020-09-23 Artifact Rates for 2D Retinal Nerve Fiber Layer Thickness Versus 3D Neuroretinal Rim Thickness Using Spectral-Domain Optical Coherence Tomography Park, Elli A. Tsikata, Edem Lee, Jenny Jyoung Shieh, Eric Braaf, Boy Vakoc, Benjamin J. Bouma, Brett E. de Boer, Johannes F. Chen, Teresa C. Transl Vis Sci Technol Article PURPOSE: To compare the rates of clinically significant artifacts for two-dimensional peripapillary retinal nerve fiber layer (RNFL) thickness versus three-dimensional (3D) neuroretinal rim thickness using spectral-domain optical coherence tomography (SD-OCT). METHODS: Only one eye per patient was used for analysis of 120 glaucoma patients and 114 normal patients. For RNFL scans and optic nerve scans, 15 artifact types were calculated per B-scan and per eye. Neuroretinal rim tissue was quantified by the minimum distance band (MDB). Global MDB neuroretinal rim thicknesses were calculated before and after manual deletion of B-scans with artifacts and subsequent automated interpolation. A clinically significant artifact was defined as one requiring manual correction or repeat scanning. RESULTS: Among glaucomatous eyes, artifact rates per B-scan were significantly more common in RNFL scans (61.7%, 74 of 120) compared to B-scans in neuroretinal rim volume scans (20.9%, 1423 of 6820) (95% confidence interval [CI], 31.6–50.0; P < 0.0001). For clinically significant artifact rates per eye, optic nerve scans had significantly fewer artifacts (15.8% of glaucomatous eyes, 13.2% of normal eyes) compared to RNFL scans (61.7% of glaucomatous eyes, 25.4% of normal eyes) (glaucoma group: 95% CI, 34.1–57.5, P < 0.0001; normal group: 95% CI, 1.3–23.3, P = 0.03). CONCLUSIONS: Compared to the most commonly used RNFL thickness scans, optic nerve volume scans less frequently require manual correction or repeat scanning to obtain accurate measurements. TRANSLATIONAL RELEVANCE: This paper illustrates the potential for 3D OCT algorithms to improve in vivo imaging in glaucoma. The Association for Research in Vision and Ophthalmology 2020-09-10 /pmc/articles/PMC7488619/ /pubmed/32974082 http://dx.doi.org/10.1167/tvst.9.10.10 Text en Copyright 2020 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. |
spellingShingle | Article Park, Elli A. Tsikata, Edem Lee, Jenny Jyoung Shieh, Eric Braaf, Boy Vakoc, Benjamin J. Bouma, Brett E. de Boer, Johannes F. Chen, Teresa C. Artifact Rates for 2D Retinal Nerve Fiber Layer Thickness Versus 3D Neuroretinal Rim Thickness Using Spectral-Domain Optical Coherence Tomography |
title | Artifact Rates for 2D Retinal Nerve Fiber Layer Thickness Versus 3D Neuroretinal Rim Thickness Using Spectral-Domain Optical Coherence Tomography |
title_full | Artifact Rates for 2D Retinal Nerve Fiber Layer Thickness Versus 3D Neuroretinal Rim Thickness Using Spectral-Domain Optical Coherence Tomography |
title_fullStr | Artifact Rates for 2D Retinal Nerve Fiber Layer Thickness Versus 3D Neuroretinal Rim Thickness Using Spectral-Domain Optical Coherence Tomography |
title_full_unstemmed | Artifact Rates for 2D Retinal Nerve Fiber Layer Thickness Versus 3D Neuroretinal Rim Thickness Using Spectral-Domain Optical Coherence Tomography |
title_short | Artifact Rates for 2D Retinal Nerve Fiber Layer Thickness Versus 3D Neuroretinal Rim Thickness Using Spectral-Domain Optical Coherence Tomography |
title_sort | artifact rates for 2d retinal nerve fiber layer thickness versus 3d neuroretinal rim thickness using spectral-domain optical coherence tomography |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7488619/ https://www.ncbi.nlm.nih.gov/pubmed/32974082 http://dx.doi.org/10.1167/tvst.9.10.10 |
work_keys_str_mv | AT parkellia artifactratesfor2dretinalnervefiberlayerthicknessversus3dneuroretinalrimthicknessusingspectraldomainopticalcoherencetomography AT tsikataedem artifactratesfor2dretinalnervefiberlayerthicknessversus3dneuroretinalrimthicknessusingspectraldomainopticalcoherencetomography AT leejennyjyoung artifactratesfor2dretinalnervefiberlayerthicknessversus3dneuroretinalrimthicknessusingspectraldomainopticalcoherencetomography AT shieheric artifactratesfor2dretinalnervefiberlayerthicknessversus3dneuroretinalrimthicknessusingspectraldomainopticalcoherencetomography AT braafboy artifactratesfor2dretinalnervefiberlayerthicknessversus3dneuroretinalrimthicknessusingspectraldomainopticalcoherencetomography AT vakocbenjaminj artifactratesfor2dretinalnervefiberlayerthicknessversus3dneuroretinalrimthicknessusingspectraldomainopticalcoherencetomography AT boumabrette artifactratesfor2dretinalnervefiberlayerthicknessversus3dneuroretinalrimthicknessusingspectraldomainopticalcoherencetomography AT deboerjohannesf artifactratesfor2dretinalnervefiberlayerthicknessversus3dneuroretinalrimthicknessusingspectraldomainopticalcoherencetomography AT chenteresac artifactratesfor2dretinalnervefiberlayerthicknessversus3dneuroretinalrimthicknessusingspectraldomainopticalcoherencetomography |