Cargando…

Evaluation of patellar tendon with shear wave elastography after anterior cruciate ligament reconstruction using hamstring tendons

OBJECTIVES: This study aims to evaluate the characteristics of patellar tendons (PTs) of patients who underwent anterior cruciate ligament reconstruction (ACLR) with hamstring tendon autograft using shear wave elastography (SWE). PATIENTS AND METHODS: This prospective study was conducted between Aug...

Descripción completa

Detalles Bibliográficos
Autores principales: Alp, Nazmi Bülent, Akdağ, Gökhan, Kaleli, Tufan, Macunluoğlu, Aslı Ceren, Uzunlulu, Nail
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Bayçınar Medical Publishing 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7489118/
https://www.ncbi.nlm.nih.gov/pubmed/32160507
http://dx.doi.org/10.5606/ehc.2020.71745
_version_ 1783581818304331776
author Alp, Nazmi Bülent
Akdağ, Gökhan
Kaleli, Tufan
Macunluoğlu, Aslı Ceren
Uzunlulu, Nail
author_facet Alp, Nazmi Bülent
Akdağ, Gökhan
Kaleli, Tufan
Macunluoğlu, Aslı Ceren
Uzunlulu, Nail
author_sort Alp, Nazmi Bülent
collection PubMed
description OBJECTIVES: This study aims to evaluate the characteristics of patellar tendons (PTs) of patients who underwent anterior cruciate ligament reconstruction (ACLR) with hamstring tendon autograft using shear wave elastography (SWE). PATIENTS AND METHODS: This prospective study was conducted between August 2017 and February 2018. We performed brightness mode (B-mode) ultrasound and SWE on 21 patients (20 males, 1 female; mean age 32 years; range, 19 to 42 years) who underwent ACLR with a single-bundle transtibial technique using quadruple hamstring autografts and 14 healthy controls (13 males, 1 female; mean age 35 years; range, 25 to 47 years). Length and thickness of the PT were evaluated with B-mode ultrasound, while elasticity values were evaluated with SWE in the patient and control groups. RESULTS: The mean SWE value of the patient group on the operated side was 25.30 (min-max=16.60-46.20) and on the non-operated side 23.20 (min-max=12.40-44). There were no statistically significant differences regarding PT elasticity, thickness, or length between the groups (p>0.05). CONCLUSION: There were no differences regarding elasticity, length, or thickness between the operated and healthy knees detected with SWE. Upcoming research should focus on tendon biopsy and biochemical analyses for the identification of possible intrastructural changes of the tendon due to collagen synthesis after ACLR with hamstring autograft.
format Online
Article
Text
id pubmed-7489118
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Bayçınar Medical Publishing
record_format MEDLINE/PubMed
spelling pubmed-74891182020-09-17 Evaluation of patellar tendon with shear wave elastography after anterior cruciate ligament reconstruction using hamstring tendons Alp, Nazmi Bülent Akdağ, Gökhan Kaleli, Tufan Macunluoğlu, Aslı Ceren Uzunlulu, Nail Jt Dis Relat Surg Original Article OBJECTIVES: This study aims to evaluate the characteristics of patellar tendons (PTs) of patients who underwent anterior cruciate ligament reconstruction (ACLR) with hamstring tendon autograft using shear wave elastography (SWE). PATIENTS AND METHODS: This prospective study was conducted between August 2017 and February 2018. We performed brightness mode (B-mode) ultrasound and SWE on 21 patients (20 males, 1 female; mean age 32 years; range, 19 to 42 years) who underwent ACLR with a single-bundle transtibial technique using quadruple hamstring autografts and 14 healthy controls (13 males, 1 female; mean age 35 years; range, 25 to 47 years). Length and thickness of the PT were evaluated with B-mode ultrasound, while elasticity values were evaluated with SWE in the patient and control groups. RESULTS: The mean SWE value of the patient group on the operated side was 25.30 (min-max=16.60-46.20) and on the non-operated side 23.20 (min-max=12.40-44). There were no statistically significant differences regarding PT elasticity, thickness, or length between the groups (p>0.05). CONCLUSION: There were no differences regarding elasticity, length, or thickness between the operated and healthy knees detected with SWE. Upcoming research should focus on tendon biopsy and biochemical analyses for the identification of possible intrastructural changes of the tendon due to collagen synthesis after ACLR with hamstring autograft. Bayçınar Medical Publishing 2020-03-02 /pmc/articles/PMC7489118/ /pubmed/32160507 http://dx.doi.org/10.5606/ehc.2020.71745 Text en Copyright © 2020, Turkish Joint Diseases Foundation http://creativecommons.org/licenses/by-nc/4.0/ This is an open access article under the terms of the Creative Commons Attribution-NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle Original Article
Alp, Nazmi Bülent
Akdağ, Gökhan
Kaleli, Tufan
Macunluoğlu, Aslı Ceren
Uzunlulu, Nail
Evaluation of patellar tendon with shear wave elastography after anterior cruciate ligament reconstruction using hamstring tendons
title Evaluation of patellar tendon with shear wave elastography after anterior cruciate ligament reconstruction using hamstring tendons
title_full Evaluation of patellar tendon with shear wave elastography after anterior cruciate ligament reconstruction using hamstring tendons
title_fullStr Evaluation of patellar tendon with shear wave elastography after anterior cruciate ligament reconstruction using hamstring tendons
title_full_unstemmed Evaluation of patellar tendon with shear wave elastography after anterior cruciate ligament reconstruction using hamstring tendons
title_short Evaluation of patellar tendon with shear wave elastography after anterior cruciate ligament reconstruction using hamstring tendons
title_sort evaluation of patellar tendon with shear wave elastography after anterior cruciate ligament reconstruction using hamstring tendons
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7489118/
https://www.ncbi.nlm.nih.gov/pubmed/32160507
http://dx.doi.org/10.5606/ehc.2020.71745
work_keys_str_mv AT alpnazmibulent evaluationofpatellartendonwithshearwaveelastographyafteranteriorcruciateligamentreconstructionusinghamstringtendons
AT akdaggokhan evaluationofpatellartendonwithshearwaveelastographyafteranteriorcruciateligamentreconstructionusinghamstringtendons
AT kalelitufan evaluationofpatellartendonwithshearwaveelastographyafteranteriorcruciateligamentreconstructionusinghamstringtendons
AT macunluogluaslıceren evaluationofpatellartendonwithshearwaveelastographyafteranteriorcruciateligamentreconstructionusinghamstringtendons
AT uzunlulunail evaluationofpatellartendonwithshearwaveelastographyafteranteriorcruciateligamentreconstructionusinghamstringtendons