Cargando…
The evaluation of radiological measurements used in diagnosis and treatment of syndesmosis injury: A regional study in Turkey
OBJECTIVES: This study aims to improve the diagnostic reliability of syndesmosis injuries through evaluation of radiological measurements in the Turkish population and to provide mean reference values to prevent malreduction and overcompression during the treatment. PATIENTS AND METHODS: This retros...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Bayçınar Medical Publishing
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7489131/ https://www.ncbi.nlm.nih.gov/pubmed/32160505 http://dx.doi.org/10.5606/ehc.2020.71132 |
_version_ | 1783581821375610880 |
---|---|
author | Yaradılmış, Yüksel Uğur Polat, Yusuf Baran Uslu, Mehmet Ateş, Ahmet Demirkale, İsmail Altay, Murat |
author_facet | Yaradılmış, Yüksel Uğur Polat, Yusuf Baran Uslu, Mehmet Ateş, Ahmet Demirkale, İsmail Altay, Murat |
author_sort | Yaradılmış, Yüksel Uğur |
collection | PubMed |
description | OBJECTIVES: This study aims to improve the diagnostic reliability of syndesmosis injuries through evaluation of radiological measurements in the Turkish population and to provide mean reference values to prevent malreduction and overcompression during the treatment. PATIENTS AND METHODS: This retrospective study was performed between January 2018 and May 2018. The bilateral anteroposterior (AP) and lateral radiographs of 100 patients (60 males, 40 females; mean age 42.9 years; range, 23 to 72 years) who presented at our polyclinic were analyzed. Tibiofibular overlap (TFO), tibiofibular clear space (TFCS) and medial clear space (MCS) measurements were performed on the AP radiographs. The lateral radiographs were evaluated in respect of the anterior tibiofibular interval (ATFI), posterior tibiofibular interval (PTFI), and anterior tibiofibular ratio (ATFR) for syndesmosis reduction assessment. The lower and upper limits, mean and median values of the measurements were recorded. RESULTS: The measurements on the AP radiographs were determined to be as TFO: 7.9±2.4 mm (4-13), TFCS: 3.8±0.9 mm (2.2-6), MCS: 3.3±0.4 mm (2.7-4.5), and superior clear space: 3.3±0.3 mm (2.7-3.8). According to the measurements on the AP radiographs, the TFCS did not show any difference in terms of the variables of age, gender and side (p=0.070, p=0.219 and p=1.0, respectively). These measurements on the AP radiographs showed a high statistical consistency in terms of side (p=0.72, p=1.0, p=0.900 and p=0.920, respectively). The measurements on the lateral radiographs were as ATFI: 12.8±2.4 mm (8-18), PTFI: 6.1±2.9 mm (3-15) and ATFR: 0.4±0.1 (0.28-0.5). According to the measurements on the lateral radiographs, the ATFR did not show any difference in terms of the variables of age, gender and side (p=0.750, p=0.570 and p=0.848, respectively). The lateral measurements indicated statistical consistency in terms of side (p=0.400, p=0.260 and p=0.848, respectively). CONCLUSION: On the AP radiographs, TFCS was found to be reliable and the intraoperative evaluation of its high consistency with the opposite extremity is appropriate to avoid overcompression. The evaluation of ATFR on lateral radiographs was found to be reliable and evaluation is recommended to avoid intraoperative malreduction. |
format | Online Article Text |
id | pubmed-7489131 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | Bayçınar Medical Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-74891312020-09-17 The evaluation of radiological measurements used in diagnosis and treatment of syndesmosis injury: A regional study in Turkey Yaradılmış, Yüksel Uğur Polat, Yusuf Baran Uslu, Mehmet Ateş, Ahmet Demirkale, İsmail Altay, Murat Jt Dis Relat Surg Original Article OBJECTIVES: This study aims to improve the diagnostic reliability of syndesmosis injuries through evaluation of radiological measurements in the Turkish population and to provide mean reference values to prevent malreduction and overcompression during the treatment. PATIENTS AND METHODS: This retrospective study was performed between January 2018 and May 2018. The bilateral anteroposterior (AP) and lateral radiographs of 100 patients (60 males, 40 females; mean age 42.9 years; range, 23 to 72 years) who presented at our polyclinic were analyzed. Tibiofibular overlap (TFO), tibiofibular clear space (TFCS) and medial clear space (MCS) measurements were performed on the AP radiographs. The lateral radiographs were evaluated in respect of the anterior tibiofibular interval (ATFI), posterior tibiofibular interval (PTFI), and anterior tibiofibular ratio (ATFR) for syndesmosis reduction assessment. The lower and upper limits, mean and median values of the measurements were recorded. RESULTS: The measurements on the AP radiographs were determined to be as TFO: 7.9±2.4 mm (4-13), TFCS: 3.8±0.9 mm (2.2-6), MCS: 3.3±0.4 mm (2.7-4.5), and superior clear space: 3.3±0.3 mm (2.7-3.8). According to the measurements on the AP radiographs, the TFCS did not show any difference in terms of the variables of age, gender and side (p=0.070, p=0.219 and p=1.0, respectively). These measurements on the AP radiographs showed a high statistical consistency in terms of side (p=0.72, p=1.0, p=0.900 and p=0.920, respectively). The measurements on the lateral radiographs were as ATFI: 12.8±2.4 mm (8-18), PTFI: 6.1±2.9 mm (3-15) and ATFR: 0.4±0.1 (0.28-0.5). According to the measurements on the lateral radiographs, the ATFR did not show any difference in terms of the variables of age, gender and side (p=0.750, p=0.570 and p=0.848, respectively). The lateral measurements indicated statistical consistency in terms of side (p=0.400, p=0.260 and p=0.848, respectively). CONCLUSION: On the AP radiographs, TFCS was found to be reliable and the intraoperative evaluation of its high consistency with the opposite extremity is appropriate to avoid overcompression. The evaluation of ATFR on lateral radiographs was found to be reliable and evaluation is recommended to avoid intraoperative malreduction. Bayçınar Medical Publishing 2020-03-02 /pmc/articles/PMC7489131/ /pubmed/32160505 http://dx.doi.org/10.5606/ehc.2020.71132 Text en Copyright © 2020, Turkish Joint Diseases Foundation http://creativecommons.org/licenses/by-nc/4.0/ This is an open access article under the terms of the Creative Commons Attribution-NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes. |
spellingShingle | Original Article Yaradılmış, Yüksel Uğur Polat, Yusuf Baran Uslu, Mehmet Ateş, Ahmet Demirkale, İsmail Altay, Murat The evaluation of radiological measurements used in diagnosis and treatment of syndesmosis injury: A regional study in Turkey |
title | The evaluation of radiological measurements used in diagnosis and treatment of syndesmosis injury: A regional study in Turkey |
title_full | The evaluation of radiological measurements used in diagnosis and treatment of syndesmosis injury: A regional study in Turkey |
title_fullStr | The evaluation of radiological measurements used in diagnosis and treatment of syndesmosis injury: A regional study in Turkey |
title_full_unstemmed | The evaluation of radiological measurements used in diagnosis and treatment of syndesmosis injury: A regional study in Turkey |
title_short | The evaluation of radiological measurements used in diagnosis and treatment of syndesmosis injury: A regional study in Turkey |
title_sort | evaluation of radiological measurements used in diagnosis and treatment of syndesmosis injury: a regional study in turkey |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7489131/ https://www.ncbi.nlm.nih.gov/pubmed/32160505 http://dx.doi.org/10.5606/ehc.2020.71132 |
work_keys_str_mv | AT yaradılmısyukselugur theevaluationofradiologicalmeasurementsusedindiagnosisandtreatmentofsyndesmosisinjuryaregionalstudyinturkey AT polatyusuf theevaluationofradiologicalmeasurementsusedindiagnosisandtreatmentofsyndesmosisinjuryaregionalstudyinturkey AT baranuslumehmet theevaluationofradiologicalmeasurementsusedindiagnosisandtreatmentofsyndesmosisinjuryaregionalstudyinturkey AT atesahmet theevaluationofradiologicalmeasurementsusedindiagnosisandtreatmentofsyndesmosisinjuryaregionalstudyinturkey AT demirkaleismail theevaluationofradiologicalmeasurementsusedindiagnosisandtreatmentofsyndesmosisinjuryaregionalstudyinturkey AT altaymurat theevaluationofradiologicalmeasurementsusedindiagnosisandtreatmentofsyndesmosisinjuryaregionalstudyinturkey AT yaradılmısyukselugur evaluationofradiologicalmeasurementsusedindiagnosisandtreatmentofsyndesmosisinjuryaregionalstudyinturkey AT polatyusuf evaluationofradiologicalmeasurementsusedindiagnosisandtreatmentofsyndesmosisinjuryaregionalstudyinturkey AT baranuslumehmet evaluationofradiologicalmeasurementsusedindiagnosisandtreatmentofsyndesmosisinjuryaregionalstudyinturkey AT atesahmet evaluationofradiologicalmeasurementsusedindiagnosisandtreatmentofsyndesmosisinjuryaregionalstudyinturkey AT demirkaleismail evaluationofradiologicalmeasurementsusedindiagnosisandtreatmentofsyndesmosisinjuryaregionalstudyinturkey AT altaymurat evaluationofradiologicalmeasurementsusedindiagnosisandtreatmentofsyndesmosisinjuryaregionalstudyinturkey |