Cargando…

The evaluation of radiological measurements used in diagnosis and treatment of syndesmosis injury: A regional study in Turkey

OBJECTIVES: This study aims to improve the diagnostic reliability of syndesmosis injuries through evaluation of radiological measurements in the Turkish population and to provide mean reference values to prevent malreduction and overcompression during the treatment. PATIENTS AND METHODS: This retros...

Descripción completa

Detalles Bibliográficos
Autores principales: Yaradılmış, Yüksel Uğur, Polat, Yusuf, Baran Uslu, Mehmet, Ateş, Ahmet, Demirkale, İsmail, Altay, Murat
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Bayçınar Medical Publishing 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7489131/
https://www.ncbi.nlm.nih.gov/pubmed/32160505
http://dx.doi.org/10.5606/ehc.2020.71132
_version_ 1783581821375610880
author Yaradılmış, Yüksel Uğur
Polat, Yusuf
Baran Uslu, Mehmet
Ateş, Ahmet
Demirkale, İsmail
Altay, Murat
author_facet Yaradılmış, Yüksel Uğur
Polat, Yusuf
Baran Uslu, Mehmet
Ateş, Ahmet
Demirkale, İsmail
Altay, Murat
author_sort Yaradılmış, Yüksel Uğur
collection PubMed
description OBJECTIVES: This study aims to improve the diagnostic reliability of syndesmosis injuries through evaluation of radiological measurements in the Turkish population and to provide mean reference values to prevent malreduction and overcompression during the treatment. PATIENTS AND METHODS: This retrospective study was performed between January 2018 and May 2018. The bilateral anteroposterior (AP) and lateral radiographs of 100 patients (60 males, 40 females; mean age 42.9 years; range, 23 to 72 years) who presented at our polyclinic were analyzed. Tibiofibular overlap (TFO), tibiofibular clear space (TFCS) and medial clear space (MCS) measurements were performed on the AP radiographs. The lateral radiographs were evaluated in respect of the anterior tibiofibular interval (ATFI), posterior tibiofibular interval (PTFI), and anterior tibiofibular ratio (ATFR) for syndesmosis reduction assessment. The lower and upper limits, mean and median values of the measurements were recorded. RESULTS: The measurements on the AP radiographs were determined to be as TFO: 7.9±2.4 mm (4-13), TFCS: 3.8±0.9 mm (2.2-6), MCS: 3.3±0.4 mm (2.7-4.5), and superior clear space: 3.3±0.3 mm (2.7-3.8). According to the measurements on the AP radiographs, the TFCS did not show any difference in terms of the variables of age, gender and side (p=0.070, p=0.219 and p=1.0, respectively). These measurements on the AP radiographs showed a high statistical consistency in terms of side (p=0.72, p=1.0, p=0.900 and p=0.920, respectively). The measurements on the lateral radiographs were as ATFI: 12.8±2.4 mm (8-18), PTFI: 6.1±2.9 mm (3-15) and ATFR: 0.4±0.1 (0.28-0.5). According to the measurements on the lateral radiographs, the ATFR did not show any difference in terms of the variables of age, gender and side (p=0.750, p=0.570 and p=0.848, respectively). The lateral measurements indicated statistical consistency in terms of side (p=0.400, p=0.260 and p=0.848, respectively). CONCLUSION: On the AP radiographs, TFCS was found to be reliable and the intraoperative evaluation of its high consistency with the opposite extremity is appropriate to avoid overcompression. The evaluation of ATFR on lateral radiographs was found to be reliable and evaluation is recommended to avoid intraoperative malreduction.
format Online
Article
Text
id pubmed-7489131
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Bayçınar Medical Publishing
record_format MEDLINE/PubMed
spelling pubmed-74891312020-09-17 The evaluation of radiological measurements used in diagnosis and treatment of syndesmosis injury: A regional study in Turkey Yaradılmış, Yüksel Uğur Polat, Yusuf Baran Uslu, Mehmet Ateş, Ahmet Demirkale, İsmail Altay, Murat Jt Dis Relat Surg Original Article OBJECTIVES: This study aims to improve the diagnostic reliability of syndesmosis injuries through evaluation of radiological measurements in the Turkish population and to provide mean reference values to prevent malreduction and overcompression during the treatment. PATIENTS AND METHODS: This retrospective study was performed between January 2018 and May 2018. The bilateral anteroposterior (AP) and lateral radiographs of 100 patients (60 males, 40 females; mean age 42.9 years; range, 23 to 72 years) who presented at our polyclinic were analyzed. Tibiofibular overlap (TFO), tibiofibular clear space (TFCS) and medial clear space (MCS) measurements were performed on the AP radiographs. The lateral radiographs were evaluated in respect of the anterior tibiofibular interval (ATFI), posterior tibiofibular interval (PTFI), and anterior tibiofibular ratio (ATFR) for syndesmosis reduction assessment. The lower and upper limits, mean and median values of the measurements were recorded. RESULTS: The measurements on the AP radiographs were determined to be as TFO: 7.9±2.4 mm (4-13), TFCS: 3.8±0.9 mm (2.2-6), MCS: 3.3±0.4 mm (2.7-4.5), and superior clear space: 3.3±0.3 mm (2.7-3.8). According to the measurements on the AP radiographs, the TFCS did not show any difference in terms of the variables of age, gender and side (p=0.070, p=0.219 and p=1.0, respectively). These measurements on the AP radiographs showed a high statistical consistency in terms of side (p=0.72, p=1.0, p=0.900 and p=0.920, respectively). The measurements on the lateral radiographs were as ATFI: 12.8±2.4 mm (8-18), PTFI: 6.1±2.9 mm (3-15) and ATFR: 0.4±0.1 (0.28-0.5). According to the measurements on the lateral radiographs, the ATFR did not show any difference in terms of the variables of age, gender and side (p=0.750, p=0.570 and p=0.848, respectively). The lateral measurements indicated statistical consistency in terms of side (p=0.400, p=0.260 and p=0.848, respectively). CONCLUSION: On the AP radiographs, TFCS was found to be reliable and the intraoperative evaluation of its high consistency with the opposite extremity is appropriate to avoid overcompression. The evaluation of ATFR on lateral radiographs was found to be reliable and evaluation is recommended to avoid intraoperative malreduction. Bayçınar Medical Publishing 2020-03-02 /pmc/articles/PMC7489131/ /pubmed/32160505 http://dx.doi.org/10.5606/ehc.2020.71132 Text en Copyright © 2020, Turkish Joint Diseases Foundation http://creativecommons.org/licenses/by-nc/4.0/ This is an open access article under the terms of the Creative Commons Attribution-NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle Original Article
Yaradılmış, Yüksel Uğur
Polat, Yusuf
Baran Uslu, Mehmet
Ateş, Ahmet
Demirkale, İsmail
Altay, Murat
The evaluation of radiological measurements used in diagnosis and treatment of syndesmosis injury: A regional study in Turkey
title The evaluation of radiological measurements used in diagnosis and treatment of syndesmosis injury: A regional study in Turkey
title_full The evaluation of radiological measurements used in diagnosis and treatment of syndesmosis injury: A regional study in Turkey
title_fullStr The evaluation of radiological measurements used in diagnosis and treatment of syndesmosis injury: A regional study in Turkey
title_full_unstemmed The evaluation of radiological measurements used in diagnosis and treatment of syndesmosis injury: A regional study in Turkey
title_short The evaluation of radiological measurements used in diagnosis and treatment of syndesmosis injury: A regional study in Turkey
title_sort evaluation of radiological measurements used in diagnosis and treatment of syndesmosis injury: a regional study in turkey
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7489131/
https://www.ncbi.nlm.nih.gov/pubmed/32160505
http://dx.doi.org/10.5606/ehc.2020.71132
work_keys_str_mv AT yaradılmısyukselugur theevaluationofradiologicalmeasurementsusedindiagnosisandtreatmentofsyndesmosisinjuryaregionalstudyinturkey
AT polatyusuf theevaluationofradiologicalmeasurementsusedindiagnosisandtreatmentofsyndesmosisinjuryaregionalstudyinturkey
AT baranuslumehmet theevaluationofradiologicalmeasurementsusedindiagnosisandtreatmentofsyndesmosisinjuryaregionalstudyinturkey
AT atesahmet theevaluationofradiologicalmeasurementsusedindiagnosisandtreatmentofsyndesmosisinjuryaregionalstudyinturkey
AT demirkaleismail theevaluationofradiologicalmeasurementsusedindiagnosisandtreatmentofsyndesmosisinjuryaregionalstudyinturkey
AT altaymurat theevaluationofradiologicalmeasurementsusedindiagnosisandtreatmentofsyndesmosisinjuryaregionalstudyinturkey
AT yaradılmısyukselugur evaluationofradiologicalmeasurementsusedindiagnosisandtreatmentofsyndesmosisinjuryaregionalstudyinturkey
AT polatyusuf evaluationofradiologicalmeasurementsusedindiagnosisandtreatmentofsyndesmosisinjuryaregionalstudyinturkey
AT baranuslumehmet evaluationofradiologicalmeasurementsusedindiagnosisandtreatmentofsyndesmosisinjuryaregionalstudyinturkey
AT atesahmet evaluationofradiologicalmeasurementsusedindiagnosisandtreatmentofsyndesmosisinjuryaregionalstudyinturkey
AT demirkaleismail evaluationofradiologicalmeasurementsusedindiagnosisandtreatmentofsyndesmosisinjuryaregionalstudyinturkey
AT altaymurat evaluationofradiologicalmeasurementsusedindiagnosisandtreatmentofsyndesmosisinjuryaregionalstudyinturkey