Cargando…

The effect of a new universal laser aiming device in C-arm fluoroscopy on the technician’s accuracy

OBJECTIVES: This study aims to introduce a new low-cost universal laser aiming device (LAD) that can be used in existing C-arm fluoroscopy devices, independent of brand and model, and to determine whether this new universal LAD improves technician accuracy in locating the desired region at the midpo...

Descripción completa

Detalles Bibliográficos
Autores principales: Beyaz, Salih, Kurtuldu, Hüseyin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Bayçınar Medical Publishing 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7489141/
https://www.ncbi.nlm.nih.gov/pubmed/32160486
http://dx.doi.org/10.5606/ehc.2020.71292
_version_ 1783581823662555136
author Beyaz, Salih
Kurtuldu, Hüseyin
author_facet Beyaz, Salih
Kurtuldu, Hüseyin
author_sort Beyaz, Salih
collection PubMed
description OBJECTIVES: This study aims to introduce a new low-cost universal laser aiming device (LAD) that can be used in existing C-arm fluoroscopy devices, independent of brand and model, and to determine whether this new universal LAD improves technician accuracy in locating the desired region at the midpoint of the fluoroscopic image. MATERIALS AND METHODS: A low-priced universal LAD that is compatible with existing 12-inch C-arm fluoroscopy devices was designed. Eight radiology technicians with varied levels of experience in C-arm fluoroscopy participated in the study. A 12 mm cortical screw with a diameter of 3.5 mm was placed on proximal, diaphyseal, and distal points of femur, tibia, and humerus bones in the anteroposterior plane on L3 vertebrae and the left pubis arm in the pelvis bone model. Technicians were asked to align each screw in the image center 10 times from a distance of 30 cm in the anterolateral plane, first without the LAD and then with the LAD. The distance of the screw head to the center point was measured from the 3,520 images with the help of medical viewer software based on the X- and Y-axis. RESULTS: Each fluoroscopic image was divided into 48 equal parts and the length of a part was taken as one unit for distance measurements. The compliance between technicians without the LAD was 0.347 (95% confidence interval [CI]: 0.208-0.47, p=0.001) and with the LAD was 0.687 (95% CI: 0.621-0.741, p=0.001). The distance between the screw head and the center of the image without the LAD was 19.0±9.8 for technicians with more than 10 years of experience and 28.0±12.9 for those with less than 10 years of experience. This difference was statistically significant (p=0.001). When the LAD was used, the difference between the less experienced (3.1±1.5) and more experienced (3.3±2.0) technicians was statistically reduced, along with the distance (p=0.033). CONCLUSION: The use of the LAD with C-arm fluoroscopy appears to be successful in helping technicians capture the desired point in the center of the fluoroscopic image. The use of the LAD reduces the experience gap between technicians.
format Online
Article
Text
id pubmed-7489141
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Bayçınar Medical Publishing
record_format MEDLINE/PubMed
spelling pubmed-74891412020-09-17 The effect of a new universal laser aiming device in C-arm fluoroscopy on the technician’s accuracy Beyaz, Salih Kurtuldu, Hüseyin Jt Dis Relat Surg Original Article OBJECTIVES: This study aims to introduce a new low-cost universal laser aiming device (LAD) that can be used in existing C-arm fluoroscopy devices, independent of brand and model, and to determine whether this new universal LAD improves technician accuracy in locating the desired region at the midpoint of the fluoroscopic image. MATERIALS AND METHODS: A low-priced universal LAD that is compatible with existing 12-inch C-arm fluoroscopy devices was designed. Eight radiology technicians with varied levels of experience in C-arm fluoroscopy participated in the study. A 12 mm cortical screw with a diameter of 3.5 mm was placed on proximal, diaphyseal, and distal points of femur, tibia, and humerus bones in the anteroposterior plane on L3 vertebrae and the left pubis arm in the pelvis bone model. Technicians were asked to align each screw in the image center 10 times from a distance of 30 cm in the anterolateral plane, first without the LAD and then with the LAD. The distance of the screw head to the center point was measured from the 3,520 images with the help of medical viewer software based on the X- and Y-axis. RESULTS: Each fluoroscopic image was divided into 48 equal parts and the length of a part was taken as one unit for distance measurements. The compliance between technicians without the LAD was 0.347 (95% confidence interval [CI]: 0.208-0.47, p=0.001) and with the LAD was 0.687 (95% CI: 0.621-0.741, p=0.001). The distance between the screw head and the center of the image without the LAD was 19.0±9.8 for technicians with more than 10 years of experience and 28.0±12.9 for those with less than 10 years of experience. This difference was statistically significant (p=0.001). When the LAD was used, the difference between the less experienced (3.1±1.5) and more experienced (3.3±2.0) technicians was statistically reduced, along with the distance (p=0.033). CONCLUSION: The use of the LAD with C-arm fluoroscopy appears to be successful in helping technicians capture the desired point in the center of the fluoroscopic image. The use of the LAD reduces the experience gap between technicians. Bayçınar Medical Publishing 2020-03-02 /pmc/articles/PMC7489141/ /pubmed/32160486 http://dx.doi.org/10.5606/ehc.2020.71292 Text en Copyright © 2020, Turkish Joint Diseases Foundation http://creativecommons.org/licenses/by-nc/4.0/ This is an open access article under the terms of the Creative Commons Attribution-NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle Original Article
Beyaz, Salih
Kurtuldu, Hüseyin
The effect of a new universal laser aiming device in C-arm fluoroscopy on the technician’s accuracy
title The effect of a new universal laser aiming device in C-arm fluoroscopy on the technician’s accuracy
title_full The effect of a new universal laser aiming device in C-arm fluoroscopy on the technician’s accuracy
title_fullStr The effect of a new universal laser aiming device in C-arm fluoroscopy on the technician’s accuracy
title_full_unstemmed The effect of a new universal laser aiming device in C-arm fluoroscopy on the technician’s accuracy
title_short The effect of a new universal laser aiming device in C-arm fluoroscopy on the technician’s accuracy
title_sort effect of a new universal laser aiming device in c-arm fluoroscopy on the technician’s accuracy
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7489141/
https://www.ncbi.nlm.nih.gov/pubmed/32160486
http://dx.doi.org/10.5606/ehc.2020.71292
work_keys_str_mv AT beyazsalih theeffectofanewuniversallaseraimingdeviceincarmfluoroscopyonthetechniciansaccuracy
AT kurtulduhuseyin theeffectofanewuniversallaseraimingdeviceincarmfluoroscopyonthetechniciansaccuracy
AT beyazsalih effectofanewuniversallaseraimingdeviceincarmfluoroscopyonthetechniciansaccuracy
AT kurtulduhuseyin effectofanewuniversallaseraimingdeviceincarmfluoroscopyonthetechniciansaccuracy