Cargando…

Utility of Elastography with Endoscopic Ultrasonography Shear-Wave Measurement for Diagnosing Chronic Pancreatitis

BACKGROUND/AIMS: Rosemont classification (RC) with endoscopic ultrasonography (EUS) is important for diagnosing chronic pancreatitis (CP) but is based only on subjective judgement. EUS shear wave measurement (EUS-SWM) is a precise modality based on objective judgment, but its usefulness has not been...

Descripción completa

Detalles Bibliográficos
Autores principales: Yamashita, Yasunobu, Tanioka, Kensuke, Kawaji, Yuki, Tamura, Takashi, Nuta, Junya, Hatamaru, Keiichi, Itonaga, Masahiro, Yoshida, Takeichi, Ida, Yoshiyuki, Maekita, Takao, Iguchi, Mikitaka, Kitano, Masayuki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Editorial Office of Gut and Liver 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7492489/
https://www.ncbi.nlm.nih.gov/pubmed/31722469
http://dx.doi.org/10.5009/gnl19170
_version_ 1783582375190462464
author Yamashita, Yasunobu
Tanioka, Kensuke
Kawaji, Yuki
Tamura, Takashi
Nuta, Junya
Hatamaru, Keiichi
Itonaga, Masahiro
Yoshida, Takeichi
Ida, Yoshiyuki
Maekita, Takao
Iguchi, Mikitaka
Kitano, Masayuki
author_facet Yamashita, Yasunobu
Tanioka, Kensuke
Kawaji, Yuki
Tamura, Takashi
Nuta, Junya
Hatamaru, Keiichi
Itonaga, Masahiro
Yoshida, Takeichi
Ida, Yoshiyuki
Maekita, Takao
Iguchi, Mikitaka
Kitano, Masayuki
author_sort Yamashita, Yasunobu
collection PubMed
description BACKGROUND/AIMS: Rosemont classification (RC) with endoscopic ultrasonography (EUS) is important for diagnosing chronic pancreatitis (CP) but is based only on subjective judgement. EUS shear wave measurement (EUS-SWM) is a precise modality based on objective judgment, but its usefulness has not been extensively studied yet. This study evaluated the utility of EUS-SWM for diagnosing CP and estimating CP severity by determining the presence of endocrine dysfunction along with diabetes mellitus (DM). METHODS: Between June 2018 and December 2018, 52 patients who underwent EUS and EUS-SWM were classified into two groups according to RC non-CP (indeterminate CP and normal) and CP (consistent and suggestive of CP). The EUS-SWM value by shear wave velocity was evaluated with a median value. The EUS-SWM value was compared with RC and the number of EUS features. The diagnostic accuracy and cutoff value of EUS-SWM for CP and DM and its sensitivity and specificity were calculated. RESULTS: The EUS-SWM value significantly positively correlated with the RC and the number of EUS features. The EUS-SWM values that were consistent and suggestive of CP were significantly higher than that of normal. The area under the receiver operating characteristic (AUROC) curve for the diagnostic accuracy of EUS-SWM for CP was 0.97. The cutoff value of 2.19 had 100% sensitivity and 94% specificity. For endocrine dysfunction in CP, the AUROC was 0.75. The cutoff value of 2.78 had 70% sensitivity and 56% specificity. CONCLUSIONS: EUS-SWM provides an objective assessment and can be an alternative diagnostic tool for diagnosing CP. EUS-SWM may also be useful for predicting the presence of endocrine dysfunction.
format Online
Article
Text
id pubmed-7492489
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Editorial Office of Gut and Liver
record_format MEDLINE/PubMed
spelling pubmed-74924892020-09-22 Utility of Elastography with Endoscopic Ultrasonography Shear-Wave Measurement for Diagnosing Chronic Pancreatitis Yamashita, Yasunobu Tanioka, Kensuke Kawaji, Yuki Tamura, Takashi Nuta, Junya Hatamaru, Keiichi Itonaga, Masahiro Yoshida, Takeichi Ida, Yoshiyuki Maekita, Takao Iguchi, Mikitaka Kitano, Masayuki Gut Liver Original Article BACKGROUND/AIMS: Rosemont classification (RC) with endoscopic ultrasonography (EUS) is important for diagnosing chronic pancreatitis (CP) but is based only on subjective judgement. EUS shear wave measurement (EUS-SWM) is a precise modality based on objective judgment, but its usefulness has not been extensively studied yet. This study evaluated the utility of EUS-SWM for diagnosing CP and estimating CP severity by determining the presence of endocrine dysfunction along with diabetes mellitus (DM). METHODS: Between June 2018 and December 2018, 52 patients who underwent EUS and EUS-SWM were classified into two groups according to RC non-CP (indeterminate CP and normal) and CP (consistent and suggestive of CP). The EUS-SWM value by shear wave velocity was evaluated with a median value. The EUS-SWM value was compared with RC and the number of EUS features. The diagnostic accuracy and cutoff value of EUS-SWM for CP and DM and its sensitivity and specificity were calculated. RESULTS: The EUS-SWM value significantly positively correlated with the RC and the number of EUS features. The EUS-SWM values that were consistent and suggestive of CP were significantly higher than that of normal. The area under the receiver operating characteristic (AUROC) curve for the diagnostic accuracy of EUS-SWM for CP was 0.97. The cutoff value of 2.19 had 100% sensitivity and 94% specificity. For endocrine dysfunction in CP, the AUROC was 0.75. The cutoff value of 2.78 had 70% sensitivity and 56% specificity. CONCLUSIONS: EUS-SWM provides an objective assessment and can be an alternative diagnostic tool for diagnosing CP. EUS-SWM may also be useful for predicting the presence of endocrine dysfunction. Editorial Office of Gut and Liver 2020-09-15 2019-11-15 /pmc/articles/PMC7492489/ /pubmed/31722469 http://dx.doi.org/10.5009/gnl19170 Text en Copyright © 2020 by The Korean Society of Gastroenterology, the Korean Society of Gastrointestinal Endoscopy, the Korean Society of Neurogastroenterology and Motility, Korean College of Helicobacter and Upper Gastrointestinal Research, Korean Association the Study of Intestinal Diseases, the Korean Association for the Study of the Liver, Korean Pancreatobiliary Association, and Korean Society of Gastrointestinal Cancer. This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Yamashita, Yasunobu
Tanioka, Kensuke
Kawaji, Yuki
Tamura, Takashi
Nuta, Junya
Hatamaru, Keiichi
Itonaga, Masahiro
Yoshida, Takeichi
Ida, Yoshiyuki
Maekita, Takao
Iguchi, Mikitaka
Kitano, Masayuki
Utility of Elastography with Endoscopic Ultrasonography Shear-Wave Measurement for Diagnosing Chronic Pancreatitis
title Utility of Elastography with Endoscopic Ultrasonography Shear-Wave Measurement for Diagnosing Chronic Pancreatitis
title_full Utility of Elastography with Endoscopic Ultrasonography Shear-Wave Measurement for Diagnosing Chronic Pancreatitis
title_fullStr Utility of Elastography with Endoscopic Ultrasonography Shear-Wave Measurement for Diagnosing Chronic Pancreatitis
title_full_unstemmed Utility of Elastography with Endoscopic Ultrasonography Shear-Wave Measurement for Diagnosing Chronic Pancreatitis
title_short Utility of Elastography with Endoscopic Ultrasonography Shear-Wave Measurement for Diagnosing Chronic Pancreatitis
title_sort utility of elastography with endoscopic ultrasonography shear-wave measurement for diagnosing chronic pancreatitis
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7492489/
https://www.ncbi.nlm.nih.gov/pubmed/31722469
http://dx.doi.org/10.5009/gnl19170
work_keys_str_mv AT yamashitayasunobu utilityofelastographywithendoscopicultrasonographyshearwavemeasurementfordiagnosingchronicpancreatitis
AT taniokakensuke utilityofelastographywithendoscopicultrasonographyshearwavemeasurementfordiagnosingchronicpancreatitis
AT kawajiyuki utilityofelastographywithendoscopicultrasonographyshearwavemeasurementfordiagnosingchronicpancreatitis
AT tamuratakashi utilityofelastographywithendoscopicultrasonographyshearwavemeasurementfordiagnosingchronicpancreatitis
AT nutajunya utilityofelastographywithendoscopicultrasonographyshearwavemeasurementfordiagnosingchronicpancreatitis
AT hatamarukeiichi utilityofelastographywithendoscopicultrasonographyshearwavemeasurementfordiagnosingchronicpancreatitis
AT itonagamasahiro utilityofelastographywithendoscopicultrasonographyshearwavemeasurementfordiagnosingchronicpancreatitis
AT yoshidatakeichi utilityofelastographywithendoscopicultrasonographyshearwavemeasurementfordiagnosingchronicpancreatitis
AT idayoshiyuki utilityofelastographywithendoscopicultrasonographyshearwavemeasurementfordiagnosingchronicpancreatitis
AT maekitatakao utilityofelastographywithendoscopicultrasonographyshearwavemeasurementfordiagnosingchronicpancreatitis
AT iguchimikitaka utilityofelastographywithendoscopicultrasonographyshearwavemeasurementfordiagnosingchronicpancreatitis
AT kitanomasayuki utilityofelastographywithendoscopicultrasonographyshearwavemeasurementfordiagnosingchronicpancreatitis