Cargando…

Validation of MALDI-MS imaging data of selected membrane lipids in murine brain with and without laser postionization by quantitative nano-HPLC-MS using laser microdissection

MALDI mass spectrometry imaging (MALDI-MSI) is a widely used technique to map the spatial distribution of molecules in sectioned tissue. The technique is based on the systematic generation and analysis of ions from small sample volumes, each representing a single pixel of the investigated sample sur...

Descripción completa

Detalles Bibliográficos
Autores principales: Eiersbrock, Fabian B., Orthen, Julian M., Soltwisch, Jens
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7496020/
https://www.ncbi.nlm.nih.gov/pubmed/32712813
http://dx.doi.org/10.1007/s00216-020-02818-y
_version_ 1783583005552410624
author Eiersbrock, Fabian B.
Orthen, Julian M.
Soltwisch, Jens
author_facet Eiersbrock, Fabian B.
Orthen, Julian M.
Soltwisch, Jens
author_sort Eiersbrock, Fabian B.
collection PubMed
description MALDI mass spectrometry imaging (MALDI-MSI) is a widely used technique to map the spatial distribution of molecules in sectioned tissue. The technique is based on the systematic generation and analysis of ions from small sample volumes, each representing a single pixel of the investigated sample surface. Subsequently, mass spectrometric images for any recorded ion species can be generated by displaying the signal intensity at the coordinate of origin for each of these pixels. Although easily equalized, these recorded signal intensities, however, are not necessarily a good measure for the underlying amount of analyte and care has to be taken in the interpretation of MALDI-MSI data. Physical and chemical properties that define the analyte molecules’ adjacencies in the tissue largely influence the local extraction and ionization efficiencies, possibly leading to strong variations in signal intensity response. Here, we inspect the validity of signal intensity distributions recorded from murine cerebellum as a measure for the underlying molar distributions. Based on segmentation derived from MALDI-MSI measurements, laser microdissection (LMD) was used to cut out regions of interest with a homogenous signal intensity. The molar concentration of six exemplary selected membrane lipids from different lipid classes in these tissue regions was determined using quantitative nano-HPLC-ESI-MS. Comparison of molar concentrations and signal intensity revealed strong deviations between underlying concentration and the distribution suggested by MSI data. Determined signal intensity response factors strongly depend on tissue type and lipid species. [Figure: see text] ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s00216-020-02818-y) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-7496020
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-74960202020-09-29 Validation of MALDI-MS imaging data of selected membrane lipids in murine brain with and without laser postionization by quantitative nano-HPLC-MS using laser microdissection Eiersbrock, Fabian B. Orthen, Julian M. Soltwisch, Jens Anal Bioanal Chem Research Paper MALDI mass spectrometry imaging (MALDI-MSI) is a widely used technique to map the spatial distribution of molecules in sectioned tissue. The technique is based on the systematic generation and analysis of ions from small sample volumes, each representing a single pixel of the investigated sample surface. Subsequently, mass spectrometric images for any recorded ion species can be generated by displaying the signal intensity at the coordinate of origin for each of these pixels. Although easily equalized, these recorded signal intensities, however, are not necessarily a good measure for the underlying amount of analyte and care has to be taken in the interpretation of MALDI-MSI data. Physical and chemical properties that define the analyte molecules’ adjacencies in the tissue largely influence the local extraction and ionization efficiencies, possibly leading to strong variations in signal intensity response. Here, we inspect the validity of signal intensity distributions recorded from murine cerebellum as a measure for the underlying molar distributions. Based on segmentation derived from MALDI-MSI measurements, laser microdissection (LMD) was used to cut out regions of interest with a homogenous signal intensity. The molar concentration of six exemplary selected membrane lipids from different lipid classes in these tissue regions was determined using quantitative nano-HPLC-ESI-MS. Comparison of molar concentrations and signal intensity revealed strong deviations between underlying concentration and the distribution suggested by MSI data. Determined signal intensity response factors strongly depend on tissue type and lipid species. [Figure: see text] ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s00216-020-02818-y) contains supplementary material, which is available to authorized users. Springer Berlin Heidelberg 2020-07-25 2020 /pmc/articles/PMC7496020/ /pubmed/32712813 http://dx.doi.org/10.1007/s00216-020-02818-y Text en © The Author(s) 2020 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
spellingShingle Research Paper
Eiersbrock, Fabian B.
Orthen, Julian M.
Soltwisch, Jens
Validation of MALDI-MS imaging data of selected membrane lipids in murine brain with and without laser postionization by quantitative nano-HPLC-MS using laser microdissection
title Validation of MALDI-MS imaging data of selected membrane lipids in murine brain with and without laser postionization by quantitative nano-HPLC-MS using laser microdissection
title_full Validation of MALDI-MS imaging data of selected membrane lipids in murine brain with and without laser postionization by quantitative nano-HPLC-MS using laser microdissection
title_fullStr Validation of MALDI-MS imaging data of selected membrane lipids in murine brain with and without laser postionization by quantitative nano-HPLC-MS using laser microdissection
title_full_unstemmed Validation of MALDI-MS imaging data of selected membrane lipids in murine brain with and without laser postionization by quantitative nano-HPLC-MS using laser microdissection
title_short Validation of MALDI-MS imaging data of selected membrane lipids in murine brain with and without laser postionization by quantitative nano-HPLC-MS using laser microdissection
title_sort validation of maldi-ms imaging data of selected membrane lipids in murine brain with and without laser postionization by quantitative nano-hplc-ms using laser microdissection
topic Research Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7496020/
https://www.ncbi.nlm.nih.gov/pubmed/32712813
http://dx.doi.org/10.1007/s00216-020-02818-y
work_keys_str_mv AT eiersbrockfabianb validationofmaldimsimagingdataofselectedmembranelipidsinmurinebrainwithandwithoutlaserpostionizationbyquantitativenanohplcmsusinglasermicrodissection
AT orthenjulianm validationofmaldimsimagingdataofselectedmembranelipidsinmurinebrainwithandwithoutlaserpostionizationbyquantitativenanohplcmsusinglasermicrodissection
AT soltwischjens validationofmaldimsimagingdataofselectedmembranelipidsinmurinebrainwithandwithoutlaserpostionizationbyquantitativenanohplcmsusinglasermicrodissection