Cargando…

Paving the way for establishing a reference measurement system for standardization of plasma prothrombin time: Harmonizing the manual tilt tube method

BACKGROUND: International normalized ratio (INR) is traceable to World Health Organization (WHO) International Standards for thromboplastins. International Standards must be used with a manual tilt tube technique (MTT) for prothrombin time (PT) determination. An important part of the total variabili...

Descripción completa

Detalles Bibliográficos
Autores principales: van den Besselaar, Antonius M. H. P., van Rijn, Claudia J. J., Abdoel, Charmane F., Chantarangkul, Veena, Scalambrino, Erica, Kitchen, Steve, Tripodi, Armando, Woolley, Anita M., Padovan, Lidia, Cobbaert, Christa M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7496835/
https://www.ncbi.nlm.nih.gov/pubmed/32356308
http://dx.doi.org/10.1111/jth.14873
_version_ 1783583185447157760
author van den Besselaar, Antonius M. H. P.
van Rijn, Claudia J. J.
Abdoel, Charmane F.
Chantarangkul, Veena
Scalambrino, Erica
Kitchen, Steve
Tripodi, Armando
Woolley, Anita M.
Padovan, Lidia
Cobbaert, Christa M.
author_facet van den Besselaar, Antonius M. H. P.
van Rijn, Claudia J. J.
Abdoel, Charmane F.
Chantarangkul, Veena
Scalambrino, Erica
Kitchen, Steve
Tripodi, Armando
Woolley, Anita M.
Padovan, Lidia
Cobbaert, Christa M.
author_sort van den Besselaar, Antonius M. H. P.
collection PubMed
description BACKGROUND: International normalized ratio (INR) is traceable to World Health Organization (WHO) International Standards for thromboplastins. International Standards must be used with a manual tilt tube technique (MTT) for prothrombin time (PT) determination. An important part of the total variability of INR is due to poor harmonization of MTT across WHO reference laboratories. OBJECTIVES: To determine the origins of PT differences between operators performing MTT and to develop a harmonized MTT. METHODS: Two workshops were held where WHO reference laboratory operators could compare their PTs using MTT and the same equipment. A harmonized MTT was used by seven operators in the second workshop. RESULTS: Differences have been observed in tilting frequency and in the height of pipetting plasma in the test tube. At the beginning of the first workshop, the tilting cycle time varied between 1.1 and 2.7 seconds. The mean PT of normal plasma obtained by pipetting plasma at the top of the tube was 14.3 seconds but was 12.9 seconds when plasma was pipetted at the bottom of the tube. When using the harmonized MTT for WHO International Standard rTF/16, the differences between operators were not greater than 1.1 seconds in normal plasma, and not greater than 1.3 seconds in patient plasma with average INR of 3.0. INR between‐operator coefficient of variation was 2.3%. CONCLUSION: Application of a harmonized MTT in three reference laboratories resulted in substantial reduction of between‐operator variation of PT and INR. The harmonized MTT is proposed as Candidate Reference Measurement Procedure.
format Online
Article
Text
id pubmed-7496835
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-74968352020-09-25 Paving the way for establishing a reference measurement system for standardization of plasma prothrombin time: Harmonizing the manual tilt tube method van den Besselaar, Antonius M. H. P. van Rijn, Claudia J. J. Abdoel, Charmane F. Chantarangkul, Veena Scalambrino, Erica Kitchen, Steve Tripodi, Armando Woolley, Anita M. Padovan, Lidia Cobbaert, Christa M. J Thromb Haemost THROMBOSIS BACKGROUND: International normalized ratio (INR) is traceable to World Health Organization (WHO) International Standards for thromboplastins. International Standards must be used with a manual tilt tube technique (MTT) for prothrombin time (PT) determination. An important part of the total variability of INR is due to poor harmonization of MTT across WHO reference laboratories. OBJECTIVES: To determine the origins of PT differences between operators performing MTT and to develop a harmonized MTT. METHODS: Two workshops were held where WHO reference laboratory operators could compare their PTs using MTT and the same equipment. A harmonized MTT was used by seven operators in the second workshop. RESULTS: Differences have been observed in tilting frequency and in the height of pipetting plasma in the test tube. At the beginning of the first workshop, the tilting cycle time varied between 1.1 and 2.7 seconds. The mean PT of normal plasma obtained by pipetting plasma at the top of the tube was 14.3 seconds but was 12.9 seconds when plasma was pipetted at the bottom of the tube. When using the harmonized MTT for WHO International Standard rTF/16, the differences between operators were not greater than 1.1 seconds in normal plasma, and not greater than 1.3 seconds in patient plasma with average INR of 3.0. INR between‐operator coefficient of variation was 2.3%. CONCLUSION: Application of a harmonized MTT in three reference laboratories resulted in substantial reduction of between‐operator variation of PT and INR. The harmonized MTT is proposed as Candidate Reference Measurement Procedure. John Wiley and Sons Inc. 2020-06-25 2020-08 /pmc/articles/PMC7496835/ /pubmed/32356308 http://dx.doi.org/10.1111/jth.14873 Text en 2020 The Authors. Journal of Thrombosis and Haemostasis published by Wiley Periodicals LLC on behalf of International Society on Thrombosis and Haemostasis This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle THROMBOSIS
van den Besselaar, Antonius M. H. P.
van Rijn, Claudia J. J.
Abdoel, Charmane F.
Chantarangkul, Veena
Scalambrino, Erica
Kitchen, Steve
Tripodi, Armando
Woolley, Anita M.
Padovan, Lidia
Cobbaert, Christa M.
Paving the way for establishing a reference measurement system for standardization of plasma prothrombin time: Harmonizing the manual tilt tube method
title Paving the way for establishing a reference measurement system for standardization of plasma prothrombin time: Harmonizing the manual tilt tube method
title_full Paving the way for establishing a reference measurement system for standardization of plasma prothrombin time: Harmonizing the manual tilt tube method
title_fullStr Paving the way for establishing a reference measurement system for standardization of plasma prothrombin time: Harmonizing the manual tilt tube method
title_full_unstemmed Paving the way for establishing a reference measurement system for standardization of plasma prothrombin time: Harmonizing the manual tilt tube method
title_short Paving the way for establishing a reference measurement system for standardization of plasma prothrombin time: Harmonizing the manual tilt tube method
title_sort paving the way for establishing a reference measurement system for standardization of plasma prothrombin time: harmonizing the manual tilt tube method
topic THROMBOSIS
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7496835/
https://www.ncbi.nlm.nih.gov/pubmed/32356308
http://dx.doi.org/10.1111/jth.14873
work_keys_str_mv AT vandenbesselaarantoniusmhp pavingthewayforestablishingareferencemeasurementsystemforstandardizationofplasmaprothrombintimeharmonizingthemanualtilttubemethod
AT vanrijnclaudiajj pavingthewayforestablishingareferencemeasurementsystemforstandardizationofplasmaprothrombintimeharmonizingthemanualtilttubemethod
AT abdoelcharmanef pavingthewayforestablishingareferencemeasurementsystemforstandardizationofplasmaprothrombintimeharmonizingthemanualtilttubemethod
AT chantarangkulveena pavingthewayforestablishingareferencemeasurementsystemforstandardizationofplasmaprothrombintimeharmonizingthemanualtilttubemethod
AT scalambrinoerica pavingthewayforestablishingareferencemeasurementsystemforstandardizationofplasmaprothrombintimeharmonizingthemanualtilttubemethod
AT kitchensteve pavingthewayforestablishingareferencemeasurementsystemforstandardizationofplasmaprothrombintimeharmonizingthemanualtilttubemethod
AT tripodiarmando pavingthewayforestablishingareferencemeasurementsystemforstandardizationofplasmaprothrombintimeharmonizingthemanualtilttubemethod
AT woolleyanitam pavingthewayforestablishingareferencemeasurementsystemforstandardizationofplasmaprothrombintimeharmonizingthemanualtilttubemethod
AT padovanlidia pavingthewayforestablishingareferencemeasurementsystemforstandardizationofplasmaprothrombintimeharmonizingthemanualtilttubemethod
AT cobbaertchristam pavingthewayforestablishingareferencemeasurementsystemforstandardizationofplasmaprothrombintimeharmonizingthemanualtilttubemethod