Cargando…

Dosimetric benefits of gantry‐static couch‐motion (GsCM) technique for breast boost radiation therapy: Reduced dose to organs‐at‐risk and improved dosimetric indices

To evaluate the clinical feasibility and dosimetric benefits of a novel gantry‐static couch‐motion (GsCM) technique for external beam photon boost treatment of lumpectomy cavity in patients with early‐stage breast cancer in comparison to three‐dimensional conformal radiotherapy (3D‐CRT), wedge pair...

Descripción completa

Detalles Bibliográficos
Autores principales: Gill, Gurtej S., Jakubovic, Raphael Y., Baker, Jameson, Button, Terry, Chang, Jenghwa
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7497924/
https://www.ncbi.nlm.nih.gov/pubmed/32627294
http://dx.doi.org/10.1002/acm2.12969
_version_ 1783583408117514240
author Gill, Gurtej S.
Jakubovic, Raphael Y.
Baker, Jameson
Button, Terry
Chang, Jenghwa
author_facet Gill, Gurtej S.
Jakubovic, Raphael Y.
Baker, Jameson
Button, Terry
Chang, Jenghwa
author_sort Gill, Gurtej S.
collection PubMed
description To evaluate the clinical feasibility and dosimetric benefits of a novel gantry‐static couch‐motion (GsCM) technique for external beam photon boost treatment of lumpectomy cavity in patients with early‐stage breast cancer in comparison to three‐dimensional conformal radiotherapy (3D‐CRT), wedge pair in supine position (WPS), and wedge pair in decubitus position (WPD) techniques. A retrospective review was conducted on breast patients (right breast, n = 10 and left breast, n = 10) who received 10 Gy boost after 50 Gy to whole breast. The treatment plans were generated using an isocentric‐based GsCM technique (a VMAT type planning approach) integrating couch rotational motion at static gantry positions. Static fields for each tangential side were merged using a Matlab(®) script and delivered automatically within the Varian Truebeam(TM) STx in Developer Mode application as a VMAT arc (wide‐angular medial and short‐angular lateral arcs). The dosimetric accuracy of the plan delivery was evaluated by ion chamber array measurements in phantom. For both right and left breast boost GsCM, 3D‐CRT, WPS, and WPD all provided an adequate coverage to PTV. GsCM significantly reduced the ipsilateral lung V30% for right side (mean, 80%) and left side (mean, 70%). Heart V5% reduced by 90% (mean) for right and 80% (mean) for left side. Ipsilateral breast V50% and mean dose were comparable for all techniques but for GsCM, V100% reduced by 50% (mean) for right and left side. The automated delivery of both arcs was under 2 min as compared to delivering individual fields (30 ± 5 min). The gamma analysis using 2 mm distance to agreement (DTA) and 2% dose difference (DD) was 98 ± 1.5% for all 20 plans. The GsCM technique facilitates coronal plane dose delivery appropriate for deep‐seated breast boost cavities, with sufficient dose conformity of target volume paired with sparing of the OARs.
format Online
Article
Text
id pubmed-7497924
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-74979242020-09-25 Dosimetric benefits of gantry‐static couch‐motion (GsCM) technique for breast boost radiation therapy: Reduced dose to organs‐at‐risk and improved dosimetric indices Gill, Gurtej S. Jakubovic, Raphael Y. Baker, Jameson Button, Terry Chang, Jenghwa J Appl Clin Med Phys Radiation Oncology Physics To evaluate the clinical feasibility and dosimetric benefits of a novel gantry‐static couch‐motion (GsCM) technique for external beam photon boost treatment of lumpectomy cavity in patients with early‐stage breast cancer in comparison to three‐dimensional conformal radiotherapy (3D‐CRT), wedge pair in supine position (WPS), and wedge pair in decubitus position (WPD) techniques. A retrospective review was conducted on breast patients (right breast, n = 10 and left breast, n = 10) who received 10 Gy boost after 50 Gy to whole breast. The treatment plans were generated using an isocentric‐based GsCM technique (a VMAT type planning approach) integrating couch rotational motion at static gantry positions. Static fields for each tangential side were merged using a Matlab(®) script and delivered automatically within the Varian Truebeam(TM) STx in Developer Mode application as a VMAT arc (wide‐angular medial and short‐angular lateral arcs). The dosimetric accuracy of the plan delivery was evaluated by ion chamber array measurements in phantom. For both right and left breast boost GsCM, 3D‐CRT, WPS, and WPD all provided an adequate coverage to PTV. GsCM significantly reduced the ipsilateral lung V30% for right side (mean, 80%) and left side (mean, 70%). Heart V5% reduced by 90% (mean) for right and 80% (mean) for left side. Ipsilateral breast V50% and mean dose were comparable for all techniques but for GsCM, V100% reduced by 50% (mean) for right and left side. The automated delivery of both arcs was under 2 min as compared to delivering individual fields (30 ± 5 min). The gamma analysis using 2 mm distance to agreement (DTA) and 2% dose difference (DD) was 98 ± 1.5% for all 20 plans. The GsCM technique facilitates coronal plane dose delivery appropriate for deep‐seated breast boost cavities, with sufficient dose conformity of target volume paired with sparing of the OARs. John Wiley and Sons Inc. 2020-07-05 /pmc/articles/PMC7497924/ /pubmed/32627294 http://dx.doi.org/10.1002/acm2.12969 Text en © 2020 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Gill, Gurtej S.
Jakubovic, Raphael Y.
Baker, Jameson
Button, Terry
Chang, Jenghwa
Dosimetric benefits of gantry‐static couch‐motion (GsCM) technique for breast boost radiation therapy: Reduced dose to organs‐at‐risk and improved dosimetric indices
title Dosimetric benefits of gantry‐static couch‐motion (GsCM) technique for breast boost radiation therapy: Reduced dose to organs‐at‐risk and improved dosimetric indices
title_full Dosimetric benefits of gantry‐static couch‐motion (GsCM) technique for breast boost radiation therapy: Reduced dose to organs‐at‐risk and improved dosimetric indices
title_fullStr Dosimetric benefits of gantry‐static couch‐motion (GsCM) technique for breast boost radiation therapy: Reduced dose to organs‐at‐risk and improved dosimetric indices
title_full_unstemmed Dosimetric benefits of gantry‐static couch‐motion (GsCM) technique for breast boost radiation therapy: Reduced dose to organs‐at‐risk and improved dosimetric indices
title_short Dosimetric benefits of gantry‐static couch‐motion (GsCM) technique for breast boost radiation therapy: Reduced dose to organs‐at‐risk and improved dosimetric indices
title_sort dosimetric benefits of gantry‐static couch‐motion (gscm) technique for breast boost radiation therapy: reduced dose to organs‐at‐risk and improved dosimetric indices
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7497924/
https://www.ncbi.nlm.nih.gov/pubmed/32627294
http://dx.doi.org/10.1002/acm2.12969
work_keys_str_mv AT gillgurtejs dosimetricbenefitsofgantrystaticcouchmotiongscmtechniqueforbreastboostradiationtherapyreduceddosetoorgansatriskandimproveddosimetricindices
AT jakubovicraphaely dosimetricbenefitsofgantrystaticcouchmotiongscmtechniqueforbreastboostradiationtherapyreduceddosetoorgansatriskandimproveddosimetricindices
AT bakerjameson dosimetricbenefitsofgantrystaticcouchmotiongscmtechniqueforbreastboostradiationtherapyreduceddosetoorgansatriskandimproveddosimetricindices
AT buttonterry dosimetricbenefitsofgantrystaticcouchmotiongscmtechniqueforbreastboostradiationtherapyreduceddosetoorgansatriskandimproveddosimetricindices
AT changjenghwa dosimetricbenefitsofgantrystaticcouchmotiongscmtechniqueforbreastboostradiationtherapyreduceddosetoorgansatriskandimproveddosimetricindices