Capacitive monitoring system for real‐time respiratory motion monitoring during radiation therapy
SUMMARY: This work introduces a novel capacitive‐sensing technology capable of detecting respiratory motion with high temporal frequency (200 Hz). The system does not require contact with the patient and has the capacity to sense motion through clothing or plastic immobilization devices. ABSTRACT: P...